13
STEP 8:
POUR THE MIXED DISINFECTANT SOLUTION
INTO THE 1ST PRE-FILTER SUMP AND RE-INSTALL.
STEP 9:
OPEN THE INLET SADDLE VALVE AND OPEN
THE FAUCET. WHEN WATER BEGINS RUNNING FROM
THE FAUCET AGAIN, CLOSE THE FAUCET AND ALLOW
THE PRESSURE TANK TO FILL FOR 5 - 10 MINUTES.
WHEN THE PRESSURE TANK FEELS LIKE IT HAS
FILLED, CLOSE THE INLET SUPPLY NEEDLE VALVE.
STEP 10:
ALLOW THE SYSTEM TO SIT WITH THE
DILUTED SANITIZING SOLUTION FOR APPROXIMATELY
20 MINUTES.
STEP 11:
OPEN THE FAUCET AND PURGE THE TANK
AND SYSTEM OF THE SANITIZING SOLUTION.
STEP 12:
REINSTALL THE MEMBRANE AND REPLACE
THE
CARTRIDGES.
PURGE
THE
PRE-CARBON
CARTRIDGE OF FINES (as per installation instructions).
OPEN THE INLET SUPPLY NEEDLE VALVE AND ALLOW
SYSTEM TO FILL.
OPEN THE FAUCET AND DISCARD THE FIRST TANK
FULL OF WATER. (IF A NEW MEMBRANE ELEMENT IS
INSTALLED A THIS TIME, DISCARD THE FIRST TWO
TANKS FULL OF WATER).