Premier2 Owner’s Manual

Note: If your system is not equipped with auxiliary heat, the

thermostat may still indicate a request for auxiliary heat.

At the end of the heating cycle, the fan will remain on for

approximately 30 seconds, unless “Continuous Fan” has been
selected.

Cool

Push and release the 

MODE

 button until the display

reads 

COOL

. Your system is now in the cooling mode.

To review the cooling setpoint, momentarily press

either the 

 or 

  button and you will see the current

setpoint and 

DESIRED TEMP

 on the display.

To adjust the setpoint, press and hold either the 

or 

button until the desired temperature is displayed. Note: As the
cooling setpoint is adjusted, the words 

DESIRED TEMP

 will be displayed.

The words 

COOL

 and 

ENERGY SAVINGS

 will be displayed when the system is

operating in the cooling mode. The cooling cycle starts with the fan and compressor on a
lower speed. (For single-speed units there is only one compressor speed.) This lower
speed increases humidity removal and reduces sound levels.  Note: It is normal for the
Premier two-speed GeoExchange system to have extended run times in low speed. The
Premier two-speed is most efficient in low speed operation. Should the thermostat require
maximum cooling capacity, the fan and compressor will switch to a higher speed. (For
single-speed units there is only one compressor speed.)

At the end of the cooling cycle, the fan will remain on for approximately 30 seconds,

unless “Continuous Fan” has been selected.

Auto

Push and release the 

MODE

 button until the display

reads 

AUTO

. Your system is now in the automatic

mode, with either heating or cooling operation available.

To review the heating and cooling setpoints,

momentarily press either the 

or 

 button. The

thermostat will then either display the current heating
setpoint and the word 

HEAT

, or the cooling setpoint and

the word 

COOL

. If the heating setpoint and the word 

HEAT

is displayed, pressing the 

MODE 

button within five seconds will

display the cooling setpoint and the word 

COOL

. If the cooling setpoint and the word

COOL 

is displayed, pressing the 

MODE 

button within five seconds will display the heating

setpoint and the word 

HEAT

.

Summary of Contents for Premier2

Page 1: ......

Page 2: ...Benefits 3 How GeoExchange Systems Work 4 GeoExchange System Types 5 WaterFurnace Quality Commitment 6 Warranty 6 Thermostat Operating Procedures 7 12 Premier2 Status Lights 12 14 System Maintenance 1...

Page 3: ...mney or odors backed by the industry s best warranties low maintenance requirements improves the environment by not burning fossil fuels no carbon monoxide emissions Energy Efficient GeoExchange syste...

Page 4: ...derground pipe absorbs heat from the earth and carries it to the Premier2 unit which extracts the heat compresses it to a higher temperature and distributes it via a duct system During the cooling sea...

Page 5: ...h as a ditch field tile pond or stream An open loop system may require periodic inspection cleaning to prevent buildup of mineral deposits Closed loop systems The GeoExchange closed loop system is an...

Page 6: ......

Page 7: ...e Note WaterFurnace offers several different thermostats that can be used with your Premier2 system The instructions that follow apply only to the type of thermostat pictured here For operating instru...

Page 8: ...either the or button and you will see your current setpoint displayed along with the words DESIRED TEMP illuminated on the display The display will read HEAT and ENERGY SAVINGS when the system is ope...

Page 9: ...removal and reduces sound levels Note It is normal for the Premier two speed GeoExchange system to have extended run times in low speed The Premier two speed is most efficient in low speed operation S...

Page 10: ...ush and release the MODE button until the display reads OFF When the word OFF is displayed the system will not provide heating or cooling The display still shows room temperature and the fan is operab...

Page 11: ...airflow Check clean or replace filter Reset the unit see page 15 If unit still does not operate or the TROUBLE display is still on call your WaterFurnace dealer What if the words CLEAN FILTER are disp...

Page 12: ...ing slowly operation may seem normal but there is a problem Call your WaterFurnace dealer for assistance TYPICAL INSTALLATION Filter Rack Flow Center Status Lights To Loop What do I need to know about...

Page 13: ...reezing conditions have occurred This may be caused by a pump failure low antifreeze level or air pockets in the loop piping see resetting the unit section page 15 Low Pressure When this light is on i...

Page 14: ...ols does my unit have Your WaterFurnace Premier2 unit is equipped with safety controls which are designed to protect the unit in case of improper airflow water flow or refrigerant charge These safety...

Page 15: ...ae To gain access to the drain pan for inspection Turn off all power to unit and auxiliary heat Remove the screw located above the top center of the fan compartment door Lift the door up and pull out...

Page 16: ...ure the thermostat is set properly Check to make sure the electrical disconnect switches are in the ON position Both the unit and auxiliary heat if present must be powered for proper operation Check f...

Page 17: ...Date of Purchase Type of System Closed Loop Open Loop Well Water Pond Loop Auxiliary Heat Yes No If yes what kW Loop Length Unit Model Serial Options Extended Warranties Equipment Loop Once again than...

Page 18: ...18 Premier2 Owner s Manual Notes...

Page 19: ...19 Premier2 Owner s Manual Notes...

Page 20: ......

Reviews: