15

Premier2 Owner’s Manual

Water Supply for Well Water Systems

An adequate water supply to the unit is very important. Do not let anyone disrupt the water

supply by rerouting the supply line or tapping into it without first checking with your
WaterFurnace dealer. If the well pumping system requires service or is inoperable, your unit
should be turned off until an adequate water supply is restored.

Water Supply For Closed Loop Systems

No regular maintenance is required. However, if you notice air noise within the piping or

your loop is ever damaged by excavation, contact your WaterFurnace dealer.

Drain Pan

• In the cooling mode, moisture removed from the air forms as condensation on the air

coil and the resulting water runs down to the condensate drain pan. The drain can pick
up lint and dirt, especially with dirty air filters. If overflow occurs, the 

DRAIN

 light will

come on and the system will shut down.

• If the water does not run freely, clean the drain pipe. Pour a capful of bleach in the

drain pan once a year. This helps to prevent algae.

• To gain access to the drain pan for inspection: Turn off all power to unit and auxiliary

heat. Remove the screw located above the top center of the fan compartment door.
Lift the door up and pull out at the bottom. The drain pan is the black plastic or metal
rectangular pan with the drain hole in the middle.

What about regular service?

Your Premier2 system requires no regular maintenance. However, once a year or so, have

the unit inspected by an independent WaterFurnace dealer. They will check the unit’s perfor-
mance and make sure that your Premier2 unit is heating and cooling at its peak performance
level. If your unit is using a well as its water supply, your unit may need periodic cleaning to
remove mineral deposits.

If my unit shuts off, how do I reset it?

To reset the unit, repeatedly push the 

MODE 

button on the thermostat until the display

reads 

OFF

.

• If 

FAN ON

 

is displayed, it must also be turned off by pushing the 

FAN

 

button.

• The 

TROUBLE

 signal will continue flashing or remain on for up to 60 seconds after

turning the system and fan off.

• After the 

TROUBLE

 signal goes out, turn the system back on to the desired

MODE

 and re-select 

FAN ON

 if desired.

• Unit operation should resume within five minutes if heating or cooling is required.

Summary of Contents for Premier2

Page 1: ......

Page 2: ...Benefits 3 How GeoExchange Systems Work 4 GeoExchange System Types 5 WaterFurnace Quality Commitment 6 Warranty 6 Thermostat Operating Procedures 7 12 Premier2 Status Lights 12 14 System Maintenance 1...

Page 3: ...mney or odors backed by the industry s best warranties low maintenance requirements improves the environment by not burning fossil fuels no carbon monoxide emissions Energy Efficient GeoExchange syste...

Page 4: ...derground pipe absorbs heat from the earth and carries it to the Premier2 unit which extracts the heat compresses it to a higher temperature and distributes it via a duct system During the cooling sea...

Page 5: ...h as a ditch field tile pond or stream An open loop system may require periodic inspection cleaning to prevent buildup of mineral deposits Closed loop systems The GeoExchange closed loop system is an...

Page 6: ......

Page 7: ...e Note WaterFurnace offers several different thermostats that can be used with your Premier2 system The instructions that follow apply only to the type of thermostat pictured here For operating instru...

Page 8: ...either the or button and you will see your current setpoint displayed along with the words DESIRED TEMP illuminated on the display The display will read HEAT and ENERGY SAVINGS when the system is ope...

Page 9: ...removal and reduces sound levels Note It is normal for the Premier two speed GeoExchange system to have extended run times in low speed The Premier two speed is most efficient in low speed operation S...

Page 10: ...ush and release the MODE button until the display reads OFF When the word OFF is displayed the system will not provide heating or cooling The display still shows room temperature and the fan is operab...

Page 11: ...airflow Check clean or replace filter Reset the unit see page 15 If unit still does not operate or the TROUBLE display is still on call your WaterFurnace dealer What if the words CLEAN FILTER are disp...

Page 12: ...ing slowly operation may seem normal but there is a problem Call your WaterFurnace dealer for assistance TYPICAL INSTALLATION Filter Rack Flow Center Status Lights To Loop What do I need to know about...

Page 13: ...reezing conditions have occurred This may be caused by a pump failure low antifreeze level or air pockets in the loop piping see resetting the unit section page 15 Low Pressure When this light is on i...

Page 14: ...ols does my unit have Your WaterFurnace Premier2 unit is equipped with safety controls which are designed to protect the unit in case of improper airflow water flow or refrigerant charge These safety...

Page 15: ...ae To gain access to the drain pan for inspection Turn off all power to unit and auxiliary heat Remove the screw located above the top center of the fan compartment door Lift the door up and pull out...

Page 16: ...ure the thermostat is set properly Check to make sure the electrical disconnect switches are in the ON position Both the unit and auxiliary heat if present must be powered for proper operation Check f...

Page 17: ...Date of Purchase Type of System Closed Loop Open Loop Well Water Pond Loop Auxiliary Heat Yes No If yes what kW Loop Length Unit Model Serial Options Extended Warranties Equipment Loop Once again than...

Page 18: ...18 Premier2 Owner s Manual Notes...

Page 19: ...19 Premier2 Owner s Manual Notes...

Page 20: ......

Reviews: