HYDRAULICS & REQUIRED FLOW RATES
DigiHeat Model
Recommended
Minimum Flow rate
(litres / minute)
Recommended
Maximum Flow rate
(litres / minute)
2.4 kW
150
350
3.6 kW
150
350
4.8 kW
150
350
6.0 kW
150
350
10.8 kW
200
450
14.4 kW
200
450
18.0 kW
250
450
24.0 kW
250
450
04 I digiheat Titanium In line Spa Heaters
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
WARNING
!
NOTE:
In the event of digiHeat being installed more than 1.8m below the pool water level
the adjustable pressure switch will not work. A flow switch (included on three phase
models) must be installed in place of the pressure switch.
REQUIRED FLOW RATES TABLE
• digiheat products require a constant water flow rate within the minimum and maximum
recommended as stated. Any filtration device and media on the hydraulic circuit with
the digiheat unit must be cleaned on a regular basis to prevent restrictions to water flow.
• Failure to observe the recommended water flow rates may void the product warranty.
• Ideally, the optimum flow rate is the midpoint between the minimum and maximum flow
rates.
• Water must flow from left to right (when facing the
digiHeat).
There are arrows marked on the housing to assist in
determining the correct direction.
• The digiHeat should be positioned upstream from
any chemical dosing or chlorinator and a check valve
should be installed to prevent corrosive water from
flowing back into the digiHeat.