Self Diagnostics
The Bar Graph and
“ F ”
symbol indicates the following conditions:
•
F0
- The salt level may have fallen below the required level.
•
F0
- There is too much calcification on the salt cell plates for
programmed chlorine production level.
•
F0
- The pool water temperature is lower than 15° C.
•
F1
– When the current can only reach 50% of set chlorine production level.
This condition indicates that one SCR (Silicon-Controlled Rectifier ) is not working.
•
F2
– The salt cell requires replacement.
•
FL
–
No flow of water is present in the salt cell or a sensor wire has broken or the
pump is not working or connected.
Note: The microprocessor on the chlorinator will hold its memory if there is a power
interruption, ensuring that when it is turned on again, the operating sequence of the reverse
cycle is maintained.
Time Clock Operation
When the Electrochlor is set to
TIMER
, the timer
will activate both the pump and chlorinator,
as programmed.
Setting the Time Clock
Press and hold
PROG
key for 5 seconds, the day
and time displays will start blinking. Let go of the
PROG
key and program vie the
UP
or
Down
keys.
The “day” will blink
-->
Press UP
or
Down
keys to set
-->
ENTER
to confirm.
The “hour” digit will blink
-->
Press UP
or
Down
keys to set
-->
ENTER
to confirm.
The “minute” digit will blink -->
Press UP
or
Down
keys to set
-->
ENTER
to confirm.
Setting Filtration / Chlorinator Times
Press
PROG
key once and release and the
“ 123
”
will flash on the display to indicate 3 available
programming periods for filtration/chlorination times.
Use
UP
or
DOWN
keys to select either
1, 2
or
3
then
press the
ENTER
key.
The day and
ON
displays will start blinking. Use
UP
or
DOWN
keys to select the
day, week days, week end
or
ALL days
then press the
ENTER
key to confirm.
Next set the set the start time and finish time.