MANUAL REGENERATION

NOTE:

 For softeners, 

if brine tank does not 
contain salt, fill with salt 
and wait at least two hours 
before regeneration. If you 
need to initiate a manual regeneration, 
either immediately, or the same night at 
the preprogrammed time for regeneration 
(typically 2:00 AM), complete the following 
steps. 

For Immediate Regeneration:

 

Press and hold 

REGEN

 until valve motor starts (typically 5 seconds). 

For Regeneration the same night:

 

Press and release 

REGEN

 (notice that flashing “REGEN TODAY” appears).

ERROR

If the display toggles between “Error” 
and an error code (i.e. a number), 
call a service technician and report 
the error code.

BYPASS VALVE OPERATION

To shut off water to the system, position arrow handles as shown in 
the bypass operation diagram below. If your valve doesn’t look like 
the diagram below, contact your service technician for instructions 
on how to shut off water.

NORMAL OPERATION

BYPASS OPERATION

ADJUST HARDNESS, DAYS BETWEEN REGENERATION, 
OR TIME OF REGENERATION

For initial set-up or to make adjustments, 
please complete the steps as shown to 
the right. Access this mode by pressing 

NEXT

 and 

+

 button simultaneously.

NOTE:

 Hardness display shows “-nA-” 

if used as a filter. If other displays do 
not appear, refer to manual.

GENERAL OPERATION

When the system is 
operating, one of three 
displays will be shown: 
time of day, gallons of 
treated water available, 
or gallons per minute. 
Pressing 

NEXT

 will    

toggle between the 
three choices.

TO SET TIME 
OF DAY

In the event of a 
prolonged power 
outage, time of day 
flashes, indicating 
that this needs to 
be reset. All other 
information will be 
stored in memory 
no matter how long 
the power outage. 
Please complete the 
steps as shown to the 
right. To access this 
mode, press 

CLOCK

.

1.  Accessed by 

pressing 

CLOCK

2.  Adjust hours with  

+

 and 

 buttons, 

AM/PM toggles   
at 12

3. Press 

NEXT

4.  Adjust minutes with 

+

 and 

 buttons 

5.  Press 

NEXT

 to 

complete and return 
to normal operation

1.  Accessed by pressing 

NEXT

 and 

+

 button 

simultaneously

2.  Adjust hardness using 

+

 and 

 buttons

3. Press 

NEXT

4.  Adjust days between 

regenerations using 

+

 

and 

 buttons

5. Press 

NEXT

6.  Adjust time of 

regeneration hour with 

+

 and 

 buttons, 

AM/PM toggles at 12

7. Press 

NEXT

8.  Adjust time of 

regeneration minutes 
with 

+

 and 

 buttons

9.  Adjust backlight setting 

with 

+

 and 

 buttons

10.  Press 

NEXT

 to 

complete and return 
to normal operation

© 2013 WaterCare   All rights reserved.
LIT-WC CARE MAN   ENVINK   10/13   250

QUICK REFERENCE GUIDE:

1900 Prospect Court  •  Appleton, WI 54914
Phone: 920-739-9401  •  Fax: 920-739-9406

Summary of Contents for UCS-844

Page 1: ...For Models UCS 844 UCS 948 UCS 1044 UCS 1054 UCS 1248 UCS 1354 CareSoft Series Metered Water Softeners...

Page 2: ...73 TABLE OF CONTENTS Preinstallation Instructions for Dealers 3 Bypass Valve 4 Installation 5 6 Programming Procedures 7 8 Operating Displays and Instructions 9 10 Start up Instructions 11 12 Troubles...

Page 3: ...During operation the normal user display is time of day and gallons per minute Flow Rate Vacation Mode Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Vac...

Page 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Page 5: ...tank it should be located where it is easily accessible 3 Do not install any water conditioner with less than 10 feet of piping between its outlet and the inlet of a water heater 4 Do not locate unit...

Page 6: ...mmended Where the drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air...

Page 7: ...E If a resin media is used in the softener increase the grains per gallon if soluble iron is present 1 ppm 4 gpg This display will show nA not available if FILTER is selected or if AUTO is not factory...

Page 8: ...immediate manual regeneration press and hold the REGEN button for three seconds The system will begin to regenerate immediately The control may be manually stepped through the regeneration cycles by p...

Page 9: ...n for three seconds The system will begin to regenerate immediately This command cannot be cancelled Once a manual regeneration is initiated the unit will go into the FILL position This position allow...

Page 10: ...eration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use of solar pellets or rock salt Do not use block salt If pellet or rock salt is used...

Page 11: ...EGEN again and the display will read SOFTENING 240 During a full regeneration this will be a 4 hour period for salt to dissolve Press REGEN again to put the valve into BACKWASH Once valve has stopped...

Page 12: ...brine well cover 2 Pour 1 oz of household bleach into the softener brine well 3 Replace brine well cover NOTE Avoid pouring bleach directly onto the safety float components in the brine well Unit sani...

Page 13: ...d meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into three pin...

Page 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body t...

Page 15: ...on or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGE...

Page 16: ...conds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not connecte...

Page 17: ...cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3851WN PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assembly CV3186 Transformer 110V 12V...

Page 18: ...35 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215...

Page 19: ...t 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 C...

Page 20: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...

Page 21: ...bow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3...

Page 22: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench...

Page 23: ...onal 18 diameter salt grid 1 CH1080 Optional 24 diameter salt grid 1 3 CG21833CB1C00 18 x 33 brine tank black 1 CG21840CB1C00 18 x 40 brine tank black 1 CG22441CB1C00 24 x 41 brine tank black 1 4 CH10...

Page 24: ...1 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assemb...

Page 25: ...te assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly...

Page 26: ...o Max Working Pressure PSI 30 100 30 100 30 100 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1 7 2 2...

Page 27: ...xpense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition...

Page 28: ...ness display shows nA if used as a filter If other displays do not appear refer to manual GENERAL OPERATION When the system is operating one of three displays will be shown time of day gallons of trea...

Reviews: