background image

9

 OPERATING DISPLAYS AND INSTRUCTIONS:

1 .    

GENERAL OPERATION:

 

When the system is operating, one of five displays may be shown and will alternate with the 

installing dealer’s name and phone number (if set) for future service . Pressing 

next

 will alternate between the displays . 

 1 . 

 CURRENT TIME OF DAY

 and 

GPM. 

Letter indicates which tank is in service . GPM alternates with current flow rate .

 2 . 

 FLOW  RATE

 which is the current treated water flow rate through either tank A or B in Gallons Per Minute .

 3 . 

 VACATION  MODE 

allows the system to be “shut down” when there will be no water usage for an extended 

period of time .

 

4.  CAPACITY REMAINING

 for the tank in service (A or B) and the gallons that will be treated before the system 

signals a regeneration cycle and switches to the other tank . GPM alternates with current flow rate .

 5 . 

 DAYS TO A REGEN

 is the number of days left before the system goes through a regeneration cycle, based on the 

days override value . Letter indicates which tank is in service . GPM alternates with current flow rate .

 6 . 

 DEALER NAME AND PHONE NUMBER

 is the dealer information to call when service is needed (this screen will 

only appear if set by dealer) .

1

TIME OF DAY

MON

GPM

2:40

A

PM

2

FLOW RATE

GPM

8.0

A

5

DAYS TO A REGEN

GPM

3

A

6

PHONE NUMBER

DEALER NA

The user can scroll between the displays as desired .

 

2 . 

    VACATION  MODE:

 

This feature may be used to “shut down” the system while on vacation . The manufacturer has 

factory set “OFF” as the default . Turn feature “OFF” or “ON” using the 

+

 or 

 buttons . When turned “ON”, the 

unit will not regenerate while there is no water usage . Once water usage is observed (minimum of 50 gallons), the 

unit will automatically regenerate that night and resume normal operation .

CAUTION:

  Depending on the severity of water conditions and the length of no water 

usage, it may not be recommended to use this feature. Please contact 

dealer or manufacturer for more information.

3 .   

MANUAL REGENERATION:

 

Sometimes there is a need to regenerate before the control valve calls for it . This 

may be needed if the system has been operated without salt for an extended period of time . To initiate a manual 

regeneration 

immediately,

 press and hold the 

regen

 button for three seconds . The system will begin to regenerate 

immediately . 

This command cannot be cancelled.

      Once a manual regeneration is initiated, the unit will transfer to the second tank in order to supply conditioned 

water . Upon transfer, the depleted tank will begin its regeneration . 

4 .   

REGENERATION MODE:

 

Typically a twin system regenerates when the capacity 

of the tank providing treated water reaches zero remaining gallons . At this time, the 

online tank will transfer and put the standby tank online so there is no disruption 

of treated water . Once this transfer is complete, the depleted tank will regenerate 

and return to standby mode ready to enter service upon depletion of capacity of 

other tank . This two tank configuration provides for a continuous, uninterrupted 

supply of conditioned water at all times . When the system begins to regenerate, the display will change to include 

information about the step of the regeneration process and the time remaining for that step to be completed . 

The system will run through all remaining steps automatically and will reset to provide treated water when the 

regeneration process has been completed .

3

ON VACATION

NO

4

CAPACITY REMAINING

GPM

GAL

1600

A

BACKWASH

8:22

REGENERATION MODE

Summary of Contents for Evolve EV1-1044TW

Page 1: ...Evolve Series Twin Water Softeners and Conditioners For Models EV1 TW EV2 TW EVR TW EVRC TW EVRS TW EVRCS TW...

Page 2: ...Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner co...

Page 3: ...tallation are in compliance with all state and local laws and regulations For the homeowner please read Programming Procedures and Operating Displays and Instructions During operation the normal user...

Page 4: ...egeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is isola...

Page 5: ...ns only electrical 115 120V 60Hz uninterrupted outlet the tank should be on a firm level surface 1 The distance between the drain and the water conditioner should be as short as possible 2 Since salt...

Page 6: ...op at the discharge end of the line so that the bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti siphon trap Piping the drain line overhead...

Page 7: ...ill be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override using or buttons 6 is recommended set number of days between regeneration...

Page 8: ...STEP 7 ALARM BUZZER The manufacturer has factory set ON as the default An alarm will sound at the indicated time after a regeneration if there is no salt or if another error has occurred Turn the ala...

Page 9: ...d minimum of 50 gallons the unit will automatically regenerate that night and resume normal operation CAUTION Depending on the severity of water conditions and the length of no water usage it may not...

Page 10: ...turned on alerting you to these conditions To turn off alarm If the audible alarm sounds due to a low salt condition press any button on the face of the control valve to turn off If salt is not added...

Page 11: ...arily press the regen button to advance the control to the BRINE position 4 With the bypass now in diagnostic mode Fig 3 on page 4 check to verify that water is being drawn from regenerant tank with n...

Page 12: ...er to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin con...

Page 13: ...ing in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body type and piston type mix m...

Page 14: ...h piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Pres...

Page 15: ...A Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper set...

Page 16: ...ap assemblies on both sides of the valve 8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor transfer cap from the control valve the cap will spri...

Page 17: ...ult in damaging the cable 17 Position the large white drive gear with the A pointing toward the one o clock position and then press it onto the stainless steel drive shaft making sure it snaps and loc...

Page 18: ...acket spring clip 1 4 CV3502WE Evolve PC board used on chlorine generator models 1 CV4022WU Evolve PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assemb...

Page 19: ...Item No Part No Description Qty 1 CV3005 1 spacer stack assembly 1 2 CV3004 Drive cap assembly 1 3 CV3135 O ring 228 1 4 CV3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 5 CV31...

Page 20: ...20 REPLACEMENT PARTS See pages 22 23...

Page 21: ...01 T1 transfer drive cap assembly 1 15 CV4011 01 T1 transfer drive gear assembly 1 16 CV4012 T1 transfer drive gear axle 1 17 CV4013 T1 transfer reduction gear 1 18 CV3264 WS2H bypass reduction gear a...

Page 22: ...y light green not shown CV3170 O ring 011 lower not shown CV3171 O ring 013 upper The injector plug and the injector each use one lower and one upper o ring REPLACEMENT PARTS OPTIONAL CHLORINE GENERAT...

Page 23: ...CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162 042 4 2 DLFC for 3 4 elbow CV3162 053 5 3 DLFC for 3 4 elbow CV3162 065 6 5 DLFC for 3 4 e...

Page 24: ...METER PLUG Item No Part No Description Qty 1 CV3151 Nut 1 QC 1 2 CV3003 Meter assembly includes items 3 4 1 3 CV3118 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 REPL...

Page 25: ...T s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4640 32 474 float assembly 32 w 2 grommets 1 8 CH4600 50 474 safety brine valve w 5 gpm glow control 1 9 CH7016...

Page 26: ...he valve the Service Wrench shown in various positions on the valve is available to aid in assembly or disassembly SERVICE WRENCH CV3193 02 IN OUT HEAD FOR TANK B Item No Part No Description Qty CD140...

Page 27: ...Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV3152 O...

Page 28: ...TANKS Item No Part No Description Qty CV4052 01 Interconnect kit for tanks 12 and larger 1 1 CV3151 Nut 1 QC 4 2 CV3150 Split ring 4 3 CV3105 O ring 215 4 4 CV3352 1 1 4 1 1 2 PVC solvent fitting 4 5...

Page 29: ...Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2...

Page 30: ...1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 N...

Page 31: ...400 6 1 28 300 9 5 11 100 3 2 22 900 6 1 28 200 9 3 Amount of Media Cu Ft 1 0 1 5 2 5 1 0 1 5 2 5 Maximum Water Hardness GPG 20 30 40 40 60 80 2 Maximum Iron and Manganese PPM 8 0 10 0 15 0 8 0 10 0...

Page 32: ...mum 15 600 3 0 23 600 6 0 35 400 9 0 53 000 12 0 60 000 18 0 80 000 24 0 Amount of Resin Media Cu Ft 85 1 0 1 5 2 5 3 4 Maximum Water Hardness GPG 50 75 100 100 100 100 2 Minimum pH Required 7 0 7 0 7...

Page 33: ...ts expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condi...

Page 34: ...ATION When the system is operating one of six displays will be shown 1 time of day gpm 2 flow rate 3 vacation mode 4 capacity remaining 5 days to a regen 6 dealer name and phone number Pressing next w...

Page 35: ...th and buttons Default is OFF 9 Press next 10 Turn service alarm by time ON with and buttons Default is OFF 11 Press next three times 12 Turn alarm buzzer ON or OFF with and buttons 13 Press next 14 A...

Page 36: ...Manufactured exclusively for Evolve Series Dealers at 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 2014 Evolve Series All rights reserved LIT EV TW MAN 2 17...

Reviews: