Setting the Controller
This appliance features a four-button controller with an LCD display. The
controller can be used to view the appliance’s status, perform regenerations,
and change settings. The controller must be set up correctly for the appliance
to perform properly.
Note:
Ensure that the bottom of the controller is firmly locked onto the four
tabs on the top of the drive end cap assembly. See
Cabinet and Cover
Assemblies
diagram later in this manual.
To ensure that your appliance operates properly, set the controller as follows:
Figure 9: Four-Button Controller
Step 1
Set Frequency of Regeneration or Backwash
A.
Press and hold the Set button
for three seconds. When “01” displays, release the Set button.
B.
Press and release the Change button until the desired frequency number displays.
C.
Press the Set button to return to the main screen. The number you selected will be
displayed. This number indicates the number of days until the next regeneration or
backwash.
Step 2
Set Time Format
Press and hold the Set and Change buttons at the same time for 3 seconds. Display reads “12”
if the controller is set to display English units or “24” if it is set to display metric units.
To Set Time Format
A.
Press Change to toggle between 12 and 24. This controls the selection of a 12-hour (AM/PM)
or 24-hour clock. If 24-hour clock, 00=midnight.
B.
When the desired time format is displayed, press Set.
Step 3
Set Time of Day
Display reads “Set Time” and “12” (or “24”).
To Change Time of Day
A.
Press Change until the current time is displayed. Default is 12 p.m.
Note:
Set time to the nearest hour.
B.
When the desired time is displayed, press Set.
Step 4
Set Regeneration Time
Display reads “Set Reg. Time” followed by the current regeneration time that is set (02).
To Change Regeneration Time
A.
Press Change. Default is 2 AM.
B.
When the desired regeneration time is displayed, press Set.
Note:
If you have a softener installed with the filter, stagger the regeneration times. Set the
softener to regenerate first, followed by the filter.
Note:
Whenever you experience an electrical outage, check your controller for the correct time.
Make any necessary corrections.