background image

 

01/2015 

 

 

 

MINI-STRIKER Quick Guide  

This Quick Guide shows the basic operation of the 

WATERAX

 

MINI-STRIKER portable pump.  

 

The 

WATERAX

 MINI-STRIKER is a portable single-stage 

pump end paired with a Honda GXH50 gasoline engine. 
For instructions regarding the engine, as well as for oil and 
fuel recommendations, please refer to the engine 
manufacturer’s manual. 

 

For detailed instructions on using and troubleshooting your 
pump, as well as full service and maintenance instructions, 
refer to our website to download the 

MINI-STRIKER 

Owner’s Manual

 

For full specifications and performance curves, see the 

MINI-STRIKER Data Sheet

 

Warnings and Safety Precautions

 

This  warning  label  appears  on  all 

WATERAX

  pumps  to  identify  safety 

hazards as follows: 

 

READ YOUR ENGINE MANUAL!   

 

Before proceeding further, locate and read the engine 
manufacturer’s manual. It contains very important safety 
information that 

MUST

 be read, understood and followed to 

safeguard you and your equipment from harm, as well as for 
the proper use and care of your engine. Use only fuel and 
oil type recommended in the engine manufacturer’s manual. 
Always check oil level in crankcase before use.  

WEAR EAR AND EYE PROTECTION.   

 

Always wear eye and ear protection when operating the 
pump unit. Sound level of the unit: 91 dB(A).

 

 

GENERAL WARNINGS: 

 

 

Do not operate if mentally or physically fatigued. 

 

Inspect hoses and piping to avoid burst injuries. 

 

No modifications and/or alterations may be made to the 
pump. Any such modifications void the pump warranty 
and can endanger pump operators. 

 

Do not operate the pump above the maximum rated 
pressure. Use only pipe, hose, and fittings rated at or 
above the maximum pressure rating of the pump or 
system design.  

 

Slowly close valves. Use slow close valves wherever 
possible to safeguard operators and prevent damage 
from water hammer. 

 

Dry weight of the unit: 20 lbs. 

READ THE PUMP OWNER’S MANUAL! 

 

The improper use of this pump could result in serious injuries 
as well as damage to the unit. Read the 

MINI-STRIKER 

Owner’s Manual

 before using your MINI-STRIKER pump unit 

and follow the safety instructions in this Quick Guide.  

NEVER RUN THE ENGINE IN A CLOSED 
OR CONFINED AREA

.

 Exhaust gas contains 

carbon monoxide which is poisonous to humans. 
Avoid inhalation of exhaust gas.

  

REFUEL ENGINE WITH CARE

. Gasoline is 

extremely flammable, and gasoline vapor can 
explode. Refuel in a well-ventilated area, with the 
engine stopped. 

NEVER TOUCH ANY EXHAUST SYSTEM 
PARTS WHILE ENGINE IS RUNNING

. Always 

allow enough time, after stopping the unit, for proper 
cooling of these parts and surrounding areas.  

 

EQUIPMENT DAMAGE PREVENTION: 

 

Flush the pump with fresh water if the pump has been 
used to pump salty, brackish, high mineral content 
water, water containing debris, or foam injected water. 
Check that debris is cleared before using the pump 
again. 

 

Always draft water using a suction hose strainer. 

Summary of Contents for Mini-striker series

Page 1: ...sically fatigued Inspect hoses and piping to avoid burst injuries No modifications and or alterations may be made to the pump Any such modifications void the pump warranty and can endanger pump operators Do not operate the pump above the maximum rated pressure Use only pipe hose and fittings rated at or above the maximum pressure rating of the pump or system design Slowly close valves Use slow clo...

Page 2: ...quently to make sure that it is not clogged with moss leaves etc DO NOT lift strainer from water while the pump is operating Use a rope or other means to keep strainer at proper height approximately 1 foot 30 cm below water surface If strainer is too close to the water surface it will draw air and pump may lose prime 3 Connect discharge hose nozzles etc to pump and tighten firmly with coupling wre...

Page 3: ... is salty brackish or high in mineral content flush the pump with fresh water for a minimum of 2 minutes or until the water is clear b After the unit has cooled down check all fluid levels and add as needed c Completely drain the pump of all water d Break down and store all equipment as outlined by the apparatus or department procedures e Visually inspect the pump end Clean any dirt or debris from...

Page 4: ...rmation on the limited warranty provided on products manufactured by WATERAX can be found on our Web site at www waterax com WATERAX Inc 6635 Henri Bourassa W Montreal QC H4R 1E1 Tel 855 616 1818 514 637 1818 Fax 514 637 3985 E mail info waterax com Copyright 2015 WATERAX Inc Publication Number 701237 Rev 1 All rights reserved Printed in Canada ...