background image

MINI-STRIKER Quick Guide 

 

01/2015 

 

 

6.  Discharge water. 

Once the pump is primed, and with the engine running, you 
can begin to discharge water.  

a.  If pressure does not build in the discharge hose, the 

pump has not been fully primed. Prime the pump again.  

b.  Adjust the pump performance by throttling the engine 

up or down, or opening or closing discharge valves at 
various positions, or any combination of the two. 

!

  

DO NOT

 leave the pump running with all the 

discharge valves closed for more than one minute, or 
else the pump may overheat and become damaged. To 
avoid this, a re-circulation line (if provided) should be 
opened or a discharge line left slightly open to allow 
fresh water to continue to enter the pump. 

 
 
To shut down and store the MINI-STRIKER: 

1.  Shut down the pump. 

a.  Gradually reduce the engine speed. 
b.  Whenever the unit has been run at full throttle for most of the operation, allow the valves to remain slightly 

open and run the engine at idle for approximately 2 minutes before shutting down the unit. 

c.  If the unit is to be stored, move the fuel valve lever to the OFF position and wait for the engine to stop. 

Otherwise, set the ignition switch to the OFF position to shut down the engine. 

d.  Close off the hydrant/supply to the pump.  
e.  Open all valves to relieve any pressure left in the system..  

 

2.  Check and store the pump. 

a.  If the pump was last run with foam or water that is salty, brackish or high in mineral content, flush the pump 

with fresh water for a minimum of 2 minutes or until the water is clear. 

b.  After the unit has cooled down, check all fluid levels and add as needed.  
c.  Completely drain the pump of all water. 
d.  Break down and store all equipment as outlined by the apparatus or department procedures. 
e.  Visually inspect the pump end. Clean any dirt or debris from the pump unit. If necessary, a mild soap and 

water solution can be used. Note and report any performance irregularities or any abnormal mechanical 
sounds. 

f. 

Close all valves and plug all openings. 

g.  Follow any other product, component, apparatus, and departmental procedures and/or guidelines before 

placing the unit in storage. Make sure all necessary tools, spares, and accessories are with the pump. 

 

 
To operate the MINI-STRIKER in cold weather: 

 

The pump can be run in below freezing temperatures if certain precautions are taken to avoid the formation of 
ice in the pump.  

 

After priming the pump, the unit should be run at low speed for a short period of time to allow all components 
to warm up before continuing with the remaining operating procedures. 

 

Unless wrapped in a heater, drain the pump of all water if it is stopped for any length of time. The engine/drive 
unit should be turned over a few revolutions to make sure all water has been removed from the pump. Drain 
the pump priming line if a primer has been used.  

 

After use, drain the pump, manifolds, and lines of all water. You can also pour some antifreeze into the pump 
and circulate it through the pump and plumbing system. 

 
 

 

 

Summary of Contents for Mini-striker series

Page 1: ...sically fatigued Inspect hoses and piping to avoid burst injuries No modifications and or alterations may be made to the pump Any such modifications void the pump warranty and can endanger pump operators Do not operate the pump above the maximum rated pressure Use only pipe hose and fittings rated at or above the maximum pressure rating of the pump or system design Slowly close valves Use slow clo...

Page 2: ...quently to make sure that it is not clogged with moss leaves etc DO NOT lift strainer from water while the pump is operating Use a rope or other means to keep strainer at proper height approximately 1 foot 30 cm below water surface If strainer is too close to the water surface it will draw air and pump may lose prime 3 Connect discharge hose nozzles etc to pump and tighten firmly with coupling wre...

Page 3: ... is salty brackish or high in mineral content flush the pump with fresh water for a minimum of 2 minutes or until the water is clear b After the unit has cooled down check all fluid levels and add as needed c Completely drain the pump of all water d Break down and store all equipment as outlined by the apparatus or department procedures e Visually inspect the pump end Clean any dirt or debris from...

Page 4: ...rmation on the limited warranty provided on products manufactured by WATERAX can be found on our Web site at www waterax com WATERAX Inc 6635 Henri Bourassa W Montreal QC H4R 1E1 Tel 855 616 1818 514 637 1818 Fax 514 637 3985 E mail info waterax com Copyright 2015 WATERAX Inc Publication Number 701237 Rev 1 All rights reserved Printed in Canada ...

Reviews: