background image

 

 

 

CONTROL FEATURES 

           

 

 

The water conditioner must be  installed  with  the  inlet,  outlet,  and  drain  connections  made  in                                      
accordance with the manufacturer’s recommendations. Installation must meet applicable plumbing 
codes

.  

START UP INSTRUCTION “BACKWASHING “BW” AND RAPID RINSE “RR”

 

1.

 

The startup sequence 

MUST

 be allowed to finish its entire set of cycles.    

2.

 

Pushing and holding the 

Extra Cycle

 button will initiate this. 

3.

 

Backwash is a rapid upward flow of water that loosens the media bed and flushes particles, 
dirt and sediment filtered in the bed out to the drain. 

NOTE! 

Water should be clear at the 

end of the (BW) cycle if not repeat until water is clear. 

4.

 

Rapid Rinse is a fast flow of water down through the media tank that follows a Backwash 
cycle. This flushes all remaining organics from the tank and packs the carbon bed for 
efficiency. 

                     

    

NOTE

! Water should be clear at the end of the (RR) cycle if not 

repeat until water is clear. 

5.

 

Momentarily push the Extra Cycle button this will que up a cycle for that night at 12:00. 

 

 

Summary of Contents for HP02

Page 1: ...HP02 QUICKSTART PROGRAMING GUIDE ...

Page 2: ...amming 3 4 HousePure Photo Guides HousePure What s Included in Hour Whole Home System Parts List Photos 5 HousePure By Pass In Service Flow Control Photos 6 HousePure Proper Inlet Outlet Water Flow Control Photos 7 HousePure Controller Power Plug location and Drain Connection Location Photos 8 Water Inc 704 Kingshill Place Carson CA 90746 1 800 322 WATER 9283 ...

Page 3: ... 3 Backwash is a rapid upward flow of water that loosens the media bed and flushes particles dirt and sediment filtered in the bed out to the drain NOTE Water should be clear at the end of the BW cycle if not repeat until water is clear 4 Rapid Rinse is a fast flow of water down through the media tank that follows a Backwash cycle This flushes all remaining organics from the tank and packs the car...

Page 4: ...ramming is desired NOTE Some items may not be shown depending on control configuration The control will discard any changes and exit User Programming Mode if a button is not pressed for 60 seconds The information below explains the information in the User Programming Display Parameter Description TD TIME OF DAY DISPLAY SHOWS TIME OF DAY DO DAY OVERRIDE THIS CONTROL S FREQUENCY SETTING RT REFRESH T...

Page 5: ...ode The time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen Recommend days no less than 7 and no more than 30 3 Press the Extra Cycle Button to return to the home screen Press the Extra Cycle button Use this display to adjust the Regeneration Time This option setting is identified by RT...

Reviews: