Draining the DuroJet Convertible Deep Well Jet Pumps

Drain openings are provided on all models. To drain the pump:

1.  Remove the drain fitting and the prime plug to vent the system.

2.  Drain all piping to a point below the freeze line.

Draining the Tank

Conventional tanks can be drained by opening an outlet at the lowest point in the system. Remove a plug or the air volume 

control to vent the tank.

Precharged tanks force virtually all the water from the tank when the system pressure is released. No draining is necessary.

Restarting Pump

If the pump has been serviced, drained, or has not been used for some time, be sure there is water in the pump housing 

(volute) and the piping to the well. There must be water in the pump housing (volute) at all times when the pump is running to 

avoid internal damage of seal members (see page seven for priming information).

Precharged Tank

Some air is lost through the bladder in any tank. To prevent tank failure, check the tank precharge on a yearly basis.

1.  Open a faucet nearest the tank and allow all water to drain from the tank.

2.  Measure the tank precharge at the valve stem using a tire gauge.

3.  If necessary, adjust the precharge with an air pump to 2 PSI below the cut-in pressure of the pump.

Lubrication

The bearings used in the pumps are lifetime lubricated at the factory and require no additional lubrication.

Diagnosing Waterlogged Tanks – Conventional

When a tank system has an inadequate ratio of air and water, the pump will start and stop often and erratically.

1.  Disconnect the power to the pump.

2.  Open the lowest faucet in the system to release all pressurized water in the system.

3.  Prime the pump.

4.  Reconnect the power to the pump.

NoTe:  

As the pump refills the tank with water, the air volume control supplies the tank with the correct air to water ratio 

for the system to operate. If the air volume control is good, the pump will shut off at the desired cut-off and will be 

adjusted correctly.

Diagnosing Waterlogged Tanks – Precharged

If a precharged tank becomes waterlogged, the bladder is normally leaking or broken.

1.  Test the tank by depressing the air valve. The air valve will expel water if the bladder is broken.

2.  Replace the tank.

Summary of Contents for 6330

Page 1: ...n pump body or for deep well installation for water level up to 80 feet with 1 1 4 pipes and injector down in the well A pressure switch and pressure gauge are standard features The pump starts when the pressure drops to a cut in setting 30 psi and cut out setting 50 psi The DuroJet Convertible Jet Pump can be mounted to either a pre charged horizontal pressure tank or used with a pre charged free...

Page 2: ...e and void the warranty 10 Do not run the pump dry or damage will occur 11 The unit should be connected to a grounded circuit equipped with a ground fault interrupter device 12 Before installing the pump have the electrical outlet checked by a licensed or certified electrician to make sure the outlet is properly grounded 13 Make sure the line voltage and frequency of electrical current supply agre...

Page 3: ...h setting is 30 psi cut in and 50 psi cut out Wells A new well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The drawdown level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur Location Select a location as close to the water supply as possible Be sure to...

Page 4: ...rating Driven Well or Sandpoint Well 1 Drive the point several feet below the water table Note A packer type foot valve can be installed in the well This type of foot valve allows the well to be filled with water when priming and makes the inlet pipe much easier to test for leaks Follow the manufacturer s instructions when installing the packer type foot valve As an alternative an in line check va...

Page 5: ...s down in the well This pump is designed for pumping potable water in applications where the water level is up to 80 feet Drilled Well 1 Assemble the foot valve to the ejector The short tube in the ejector assembly needs to be replaced with long tube 302922 2 Connect suction pipe and drive line to the ejector as shown in the diagram on the following page 3 Install the assembly so foot valve is sub...

Page 6: ...ed The pump should be connected to a separate electrical circuit directly for the main electrical service panel Do not use an extension cord 4 It is mandatory that a permanent ground connection be made from the pump motor to the grounding bar at the service panel Do not connect the pump motor to a power supply until the pump is permanently grounded The ground wire should be copper and at least as ...

Page 7: ...roJet Convertible Deep Well Jet Pumps When using DuroJet pumps on deep well applications longer tube for ejector assembly is required WaterGroup s part number for the long tube is 302922 1 Remove prime plug from the pump discharge 2 Fill pump and piping completely full of cold water 3 Replace the prime plug 4 Make sure that the long tube is replaced with short tube in the ejector assembly 5 Start ...

Page 8: ...Open a faucet nearest the tank and allow all water to drain from the tank 2 Measure the tank precharge at the valve stem using a tire gauge 3 If necessary adjust the precharge with an air pump to 2 PSI below the cut in pressure of the pump Lubrication The bearings used in the pumps are lifetime lubricated at the factory and require no additional lubrication Diagnosing Waterlogged Tanks Conventiona...

Page 9: ...J750 1 10 302911 PLUG DRAIN PRIME DCJ500 750 1 4 18NPT 2 11 302912 O RING DIFFUSER DCJ500 750 OD 34 5 3 5 1 12 302913 O RING HOUSING DCJ500 750 OD 154 5 3 5 1 13 302914 ADAPTER PRESSURE SWITCH DCJ500 750 1 14 302915 NUT ADAPTER PRESSURE SWITCH DCJ500 750 1 15 302916 ADAPTER PRESSURE TUBE DCJ500 750 1 4 18NPT 1 16 302917 PRESSURE SWITCH DCJ500 750 1 17 302918 MECHANICAL SEAL DCJ500 750 1 19 302920 ...

Page 10: ... 12 2 6 1 0 5 60 0 15 17 3 11 8 5 9 0 5 60 0 16 16 5 11 4 5 7 0 4 60 0 18 15 2 11 1 5 5 0 1 60 0 20 14 7 10 5 5 1 57 0 22 13 4 9 8 4 9 55 0 24 12 9 9 3 4 5 53 0 25 11 5 8 1 4 4 53 0 26 11 1 7 9 4 1 28 10 9 7 6 3 8 30 10 7 6 9 3 7 3 4 HP Jet Pump Lift in Feet 30 40 50 60 70 80 Capacity in USGPM at 20 psi 6 6 6 5 4 3 Capacity in USGPM at 30 psi 6 6 5 4 3 2 Capacity in USGPM at 40 psi 5 4 3 2 1 Capac...

Page 11: ... and impeller b Check water level in well to see actual pumping level Measure vertical distance to pump and compare to tolerance for pump type c See No 2c above d Compare minimum pressure on which capacity is based with operating pressure shown on gauge e Replace suction and drive lines with larger diameter pipe f Inspect for wear on impeller nose or internal blockage a Nozzle or impeller clogged ...

Page 12: ...will be made or a replacement pump or part will be supplied free of charge The serial number of the pump must be supplied This warranty does not obligate the manufacturer to bear the cost of field labor or transportation in connection with the replacement or repair of defective parts or units nor shall it apply to any product upon which repairs or alterations have been made unless authorized by th...

Reviews: