DANGER! EXPLOSION HAZARD.

 When the well tank has been 

in  service  and  a  change  to  a  higher  pre-charge  pressure  is 

necessary  due  to  a  required  change  in  the  pressure  switch  setting,  failure  to 
follow  instructions  below  can  cause  a  rupture  or  explosion,  possibly  causing 
serious or fatal personal injury and/or property damage.

  •  Do not adjust or add pressure if there has been a loss of air.
  •  Do not adjust the pre-charge pressure if there is visible exterior corrosion.
  •  Do not adjust the pre-charge pressure if there has been a reduction of the 

pump cycle time or the pre-charge pressure compared to its initial setting. 
This is because reduction in pump cycle time can result from loss of tank air 
pressure which in turn can mean there may be internal corrosion and any 
re-pressurization or additional pressure could result in rupture or explosion.

  •  Do not install with components that are incompatible with the WWDPC.

This  product  can  expose  you  to  chemicals  including  lead, 
which is known to the State of California to cause cancer and 

birth  defects  or  other  reproductive  harm.  For  more  information  go  to  
www.P65Warnings.ca.gov. 

NOTE:

  Inspect  for  shipping  damage  and  notify  freight  carrier  or  store  where 

purchased immediately if damage is present. To avoid risk of personal injury and 
property damage, if the product appears to be malfunctioning or shows signs of 
corrosion, call a qualified professional. Please read the entire owner’s manual and 
installation instructions before installing our new Water Worker

®

 product. Save 

all  documents  and  manuals  for  future  reference.  Use  proper  safety  equipment 
when installing. You must comply with all plumbing and electrical codes.

Summary of Contents for WWDPC

Page 1: ...PC Keep this manual with the product This manual may become out of date by later amendments Check our web site www waterworkerDIY com or ask your WATER WORKER supplier for any updates relating to your...

Page 2: ...be mounted near the pressure tank or pump depending upon the installation LOCATE THE WWDPC FOLLOWING ALL LOCAL CODES DO NOT LOCATE THE UNIT WHERE IT CAN BE AFFECTED BY FLOODING 2 You may assemble the...

Page 3: ...has openings to accept standard conduit terminations Outdoor installations must use watertight connections UNIT MUST NOT BE SUPPORTED SOLELY BY THE ELECTRICAL CONDUIT WATERTIGHT CONDUIT CONNECTIONS MU...

Page 4: ...es 2 When number appears tap 5 or 6 to change cut in setting 3 Press again When HI appears tap 5 or 6 to change cut out setting This will determine the pressure at which the pump shuts off NOTE Depres...

Page 5: ...and remedy Pump rapid cycles Pressure tank too small Differential too narrow Waterlogged pressure tank Improper tank air charge Improper wiring Size tank per manufacturer s literature Spread range via...

Page 6: ...freezing temperatures or temperatures in excess of 120 degrees Failure to properly size the system or follow instructions in the Manual may result in excessive strain on the system and may lead to pr...

Page 7: ...may be internal corrosion and any re pressurization or additional pressure could result in rupture or explosion Do not install with components that are incompatible with the WWDPC This product can exp...

Page 8: ...WATER WORKER is a registered trademark in the U S and elsewhere All rights reserved T 401 884 6300 F 401 885 2567 www waterworkerdiy com...

Reviews: