REVERSE OSMOSIS SET -UP SPECIFICATIONS 

 
 

Inlet Water Supply  

Inlet Pipe Size Should Never Be Smaller Than Equipment Inlet. 
This is the inlet to the pre-filter.  Sizing can range from ½” to 3” depending on each piece of equipment. General sizing 
is as follows: 
 
 

CP Series: 150-800GPD – ½”             
WMXL / VXL / HXL Series: 1500-4000 GPD – ¾” 

WMXL / VXL / HXL Series: 4500-10000 GPD – 1” 

 

VXL / HXL Series:  10000-12000 – 1 ½”       

 

HXL Series:  12000-18000 GPD – (2) 1 ½” 

 

HXXL Series:  10500-24000 – (2) 1 ½”   

 

HXXL Series:  26000-28000 GPD  – (3) 1 ½” 

X Series: 30000 and larger – 2 –3” 

 
 

Product Water Outlet 

 

On smaller systems without flow meters, the permeate is always the center outlet of membrane housing end cap. On 
most other units the permeate outlet is the outlet of the Product Flow Meter.  The location of the permeate outlet on 
units 30000 GPD or larger is on the right side of the unit. 
 

Waste Water Outlet 

 

On smaller systems without flow meters, reject outlet is the  outside port of membrane housing, on opposite end from 
the raw water high-pressure feed. On most other units the concentrate outlet is the outlet of the  Waste Flow Meter.  
The location of the concentrate outlet on units 30000 GPD or larger is on the right side of the unit. 
 
 

Electrical Connections and Voltages 

 

All CP and WM Series standard units are 110v/60hz.  They have a standard 110v 3 prong plug.  WMXL, VXL, and 
HXL Series units are available in 110v/60hz or 220v/60hz (single or three phase).  Please check your electrical 
requirements carefully.  The equipment warranty does not cover burnouts or damage to electrical components due to 
electrical overcharge or incorrect wiring.  The 110v/60hz single-phase units have a standard 110v 3 prong plug.  Any 
220v/hz or 460v/hz units must be hard wired.  HXXL Series units are standard 220v/60hz three-phase.  X Series units 
are available in 220v/60hz three-phase or 460v/60hz three-phase.  All 460v/60hz X Series units also require 
110v/60hz circuit to be run to the electrical control box. (All systems must be installed to local codes) 
  

System Control Box:

  

 

 
All Water Tec Commercial / Industrial Reverse Osmosis units use 110v control voltage in the electrical control circuit.  
All 220v systems are converted internally to 110v.  460v units require 110v and 460v hard wired circuits. 
 
 

Liquid Level Control Connections and Switch 

 

Wiring connections for the Liquid Level Switch are located directly on top or on the side of the electrical control box. 
The two red wires are connected one to one on the wires from the Liquid Level Switch.  When the Liquid Level switch 
is closed the R.O. will turn on. When the Liquid Level Switch is open the R.O. will shut down. 

 

 
 

Summary of Contents for CP

Page 1: ...Water Tec Int l Inc Version 02A REVERSE OSMOSIS SYSTEMS OPERATING MANUAL MODELS CP WMXL WXL VXL HXL HXXL X Water Tec International Inc Tucson Arizona 85714 www water tec com...

Page 2: ...Life of a Membrane Effects of Temperature on the Reverse Osmosis Units Some Common Terms and Definitions Related to Reverse Osmosis The Reverse Osmosis System Purified Water Storage and Delivery II RE...

Page 3: ...the side of such membrane materials pure water will pass through leaving most of the impurities behind The rejection of the dissolved ionic material is a function of both molecular weight and ionic c...

Page 4: ...the water production rate EFFECTS OF TEMPERATURE ON THE REVERSE OSMOSIS UNITS In system design it is very important to consider incoming water temperature The units are rated for a product flow at 77...

Page 5: ...pressure usually to a vented storage tank In general the unit cannot be operated by opening and closing a valve at the product water line unless a special pressure relief is provided The reason for th...

Page 6: ...l switches are available from your authorized Water Tec distributor The purified water in the storage tank is distributed to the use points by means of a moderate pressure high capacity centrifugal pu...

Page 7: ...justing the Recycle Valve 8 located on the front control panel near the Waste Valve Proper recovery must be set according to unit s application 4 PERMEATE PRESSURE GAUGE 0 100 PSI liquid filled panel...

Page 8: ...re filter is 5 microns This filter is used to catch any particles that may have been missed by the Pre Treatment or any particles that may be released by faulty Pre Treatment Leaving a dirty filter ca...

Page 9: ...rol box Inlet line voltage routed through a 5 amp fuse and a 15 amp fuse for compacts 19 LIQUID LEVEL CONTROL RELAY AND SWITCH Connection leads are outside of the control box on the top or on the side...

Page 10: ...Water Tec Int l Inc Version 02A 10 GENERAL SYSTEM DIAGRAMS CP 1 Incoming Feed Water 2 10 PS05 10 Pre Filter 3 10 C1 Pre Filter 4 10 CB10 10 Pre Filter 5 Recycle Needle Valve 1 5 6 7 8 2 3 4 9 10...

Page 11: ...me 9 Electrical Control Box not shown 10 Rotary Vane Pump and Motor not shown GENERAL SYSTEMS DIAGRAM WM 1 Incoming Feed Water 5 Rotary Vane Pump Pre Filter supplied but not shown 2 Electrical Control...

Page 12: ...re Tank Optional 4 Motor GENERAL SYSTEM DIAGRAM WMXL 1 Incoming Feed Water 2 Electrical Control Box 2a On Off Switch 2b Power On Indicator 2c Low Pressure Indicator 2d 5amp Fuse 2e OPTION Digital TDS...

Page 13: ...ing Feed Water and Pre filter not shown 3 Electrical Control Box 3a On Off Switch 3b Power On Indicator 3c Low Pressure Indicator 3d 5amp Fuse 4 High Pressure Pump and Solenoid 5 Control Panel 5a Inco...

Page 14: ...ntrol Box 3a On Off Switch 3b Power On Indicator 3c Low Pressure Indicator 3d 5amp Fuse 4 Control Panel 4a Permeate Flow Meter 4b Concentrate Flow Meter 4c Incoming Pressure Gauge 4d System Pressure G...

Page 15: ...w Meter 7f Power Light 7g Low Pressure 7h Over Pressure 7i Fast Flush 7j Cleaning option 7k Power Switch 7l Clean Auto run Keyed Switch 8 Control Panel 8a Pre Filter Gauge 8b Post Filter Gauge 8c Pump...

Page 16: ...onnections and Voltages All CP and WM Series standard units are 110v 60hz They have a standard 110v 3 prong plug WMXL VXL and HXL Series units are available in 110v 60hz or 220v 60hz single or three p...

Page 17: ...Turn on the Incoming Feed Water q 5 The Incoming Pressure Gauge should rise above 20 PSI When the incoming pressure reaches approximately 20 PSI the Low Pressure Indicator will turn off q 6 After a d...

Page 18: ...m the unit to product and waste as the unit drains After the short drain out period the flow should completely stop The Power On Indicator should remain on Reconnect the Liquid Level Switch wires The...

Page 19: ...e clogged dirty Check replace Low Pressure Switch Check for power replace No high pressure Reject valve open too far Check adjust Reject bypass may be open Check adjust High pressure gauge may be brok...

Page 20: ...used in areas with higher sediment content Dirty water can clog the pre filter of the R O causing an incoming pressure drop 2 Automatic backwashing carbon filter The reverse osmosis unit CANNOT tolera...

Reviews: