WS1TC & WS1.25 TC Manual

STEP 1SS

STEP 2SS

STEP 3SS

Regeneration Cycles and Times for Different Programs

Program

All times in Minutes

C1

1st Backwash

C2

Regenerate

C3

2nd Backwash

C4

Rinse

C5

Fill

P0

3

50

3

3

1-99

P1

8

50

8

4

1-99

P2

8

70

10

6

1-99

P3

12

70

12

8

1-99

P4

10

50

Skipped

8

1-99

P5

4

50

Skipped

4

1-99

P6

12

6

Skipped

12

1-99

P7

6

Skipped

Skipped

4

Skipped

P8

10

Skipped

Skipped

6

Skipped

P9

14

Skipped

Skipped

8

Skipped

OEM General Instructions

The control valve offers multiple procedures that allow the valve to be modi

 ed to suit the needs of the installation. These 

procedures are:

• 

OEM System Setup

• 

Installer Displays & Settings (either 1-99 Days Between Regeneration option or 7-Day option)

• User 

Displays

These procedures can be accessed in any order. Details on each of the procedures are provided below and on the following pages. 

When in operation, normal user displays show the time of day or days remaining before regeneration. When stepping through a 
procedure, if no buttons are pressed within 

 ve minutes the display returns to a normal user display. Any changes made prior to the 

 ve minute time out are incorporated.

To quickly exit Installer Displays & Settings or OEM Setup, simultaneously press SET + 

. Any changes made prior to the exit are 

incorporated.

To reinitialize the control valve, check to make sure the valve is in the User Display. Then simultaneously press SET + 

 or unplug 

power source plug (4-pin connector) on the circuit board, wait 3 seconds and plug back in.

OEM System Setup

STEP 1SS 

– From normal mode, press SET + 

 buttons simultaneously for 3 seconds and release. 

Then press SET + 

 simultaneously for 3 seconds and release.

STEP 2SS

 – Choose the desired program by pressing 

 or 

. Prior to selecting a program, verify 

the correct valve body, main piston, regenerant piston, and stack are being used, and that the injector 
or injector plug(s) are in the correct locations. See Valve Body Compliance Table in the WS1 and 
WS1.25 Drawings and Service Manual.
Press SET button to go to Step 3SS.

STEP 3SS

 – If program P0 through P6 was selected, enter in the minutes of 

 ll using 

 or 

. The 

allowable values vary from a low of 1 to a high of 99. If program P7, P8 or P9 was selected, this 
screen will not appear. Press SET button to go to Step 4SS. Note: For each minute of 

 ll 0.5 gallons 

of water is added to the solution tank. With Sodium Chloride, each 0.5 gallon of water will dissolve 
1.5 pounds of salt.

Summary of Contents for WS1TC

Page 1: ...Valve Series Model WS1 25TC Operation and Instruction Manual for OEM Only Please Note This operation and instruction manual is for the training of the OEM and for the OEM to use to train their custome...

Page 2: ...tween regenerations may need to be varied based on usage and water conditions This step will not appear if the 7 day clock option is selected TO SET TIME OF DAY In the event of a prolonged power outag...

Page 3: ...Displays Settings 8 User Displays Settings 10 Drawings and Part Numbers Front Cover and Drive Assembly 12 WS1TC Drive Cap Pistons and Spacer Stack 13 WS1 25TC Drive Cap Pistons and Spacer Stack 14 WS1...

Page 4: ...can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adap...

Page 5: ...e or to have the regeneration occur immediately Simultaneously press and to start a regeneration at the next delayed regeneration time If a regeneration is to occur today an arrow will point to REGEN...

Page 6: ...the ve minute time out are incorporated To quickly exit Installer Displays Settings or OEM Setup simultaneously press SET Any changes made prior to the exit are incorporated To reinitialize the contr...

Page 7: ...etermined by the number of days that have passed since the last regeneration scheduled 7 Day Regeneration is scheduled for speci c days of the week Press SET to go to Step 5SS STEP 5SS If a differenti...

Page 8: ...the number of days between regenerations The allowable range is 1 to 99 Press SET to exit Installer Displays and Settings STEP 2ID Regeneration Time Hour Set the time for regeneration to start using...

Page 9: ...y use or until the arrow points to Regen If the arrow does not point to Regen a regeneration will not occur on Wednesday Press SET to go to STEP 9I7 STEP 9I7 Thursday Regeneration To regenerate on Thu...

Page 10: ...tion Cycle Display to indicate the current regen cycle step and time remaining An arrow will also point to Regen The system will run through the steps automatically and will reset itself to provide tr...

Page 11: ...1 E2 E3 or E4 appears on the display contact the OEM for help This indicates that the valve did not function properly STEP 1U STEP 2U Set Time of Day STEP 1U Press SET STEP 2U Current time Adjust hour...

Page 12: ...G CLIP 1 4 V3818TC WS1TC PC BOARD 4 DIGIT 1 5 V3110 WS1 DRIVE REDUCING GEAR 12 X 36 3 6 V3109 WS1 DRIVE GEAR COVER 1 V3002TC WS1TC DRIVE ASY Not Shown V3186 WS1 AC ADAPTER 120V 12V 1 V3186EU WS1 AC AD...

Page 13: ...WS1 Spacer Stack Assembly 1 2 V3004 Drive Cap ASY 1 3 V3178 WS1 Drive Back Plate 1 4 V3011 WS1 Piston Down ow ASY 1 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O...

Page 14: ...Drive Back Plate 1 4 V3407 WS1 5 Piston Down ow ASY 1 5 V3174 WS1 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3358 O ring 219 Distributor Tube Opening 1 32 1 V3357 O ring 218 Dist...

Page 15: ...1 25 with 1 32 Distributor Tube Opening Identi cation D Black Plug 1 25 1 25 Spacer Color Grey Note The WS1 down ow piston is a solid amber color Grey Plug 1 5 Spacer Color Black 1 5 WS1 25 with 32mm...

Page 16: ...Page 16 WS1TC WS1 25 TC Manual Form No V3115TC 04 4 7 2014 U S Patents 6 402 944 6 444 127 6 776 901...

Reviews: