WS1CC & WS1.25CC Manual
Page 15
STEP 1CS
STEP 2CS
STEP 3CS
➟
➟
➟
Step 3CS – Allows selection of one of the following:
• an outside signal to initiate a regeneration; or
• the Control Valve to act as an alternator.
Selecting the use of an outside signal to initiate a regeneration:
Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on
the printed circuit board. Following is an explanation of the options:
dPon0 - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur im-
mediately.
dPdEL - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the
scheduled regeneration time.
HoLd - If the dP switch is closed a regeneration will be prevented from occurring.
Selecting the Control Valve to act as an alternator:
Note: Also must do one of the following:
• If set up for a softener in Step 8S set Volume Capacity in GALLONS, in Step 9S select Regenera-
tion Time Option “on 0” and in Step 3I select Day Override “oFF”.
• If set up for a fi lter, in Step 7F set Volume Capacity in GALLONS, in Step 8F select Regeneration
Time Option “on 0” and in Step 3I select Day Override “oFF”.
Select ALTA for the control valve that has the two pin connector labeled DRIVE connected to the alter-
nator valve motor.
Select ALTb for the control valve that will not be connected to the alternator valve motor.
Confi guring the Control Valve for No Hard Water Bypass Operation:
nHbP - Selection requires that a connection to a Clack Two Way Motorized Valve or a Clack Motorized
Alternator Valve (MAV) is made to the two pin connector labeled ALTERNATOR DRIVE located on
the printed circuit board. The Clack Two Way Motorized Valve can be connected to the valve outlet in
either direction. The B port of the MAV must be plugged and the valve outlet connected to the A port.
The Clack Two Way Motorized Valve or a Clack Motorized Alternator Valve will be driven closed
before the fi rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open
after the last regeneration cycle that is not FILL.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
➟
Step 1CS – Press NEXT and
▼
simultaneously for 3 seconds and release. Then press NEXT and
▼
simultaneously for 3 seconds and release. If screen in Step 2CS does not appear in 5 seconds the lock on
the valve is activated. To unlock press
▼
, NEXT,
▲
, and SET CLOCK in sequence, then press NEXT
and
▼
simultaneously for 3 seconds and release. Then press NEXT and
▼
simultaneously for 3 seconds
and release.
Step 2CS – Press the
▼
or
▲
buttons to select 1.0 for WS1.25CC or 1.25 for WS1.25CC valves. Press
NEXT to go to Step 3CS. Press REGEN to exit OEM Cycle Sequence.
STEP 4CS
➟
Step 4CS – Press the
▼
or
▲
buttons until BACKWASH appears. Press NEXT to go to Step 5CS.
Press REGEN to return to previous step.
STEP 5CS
➟
Step 5CS - Press the
▼
or
▲
buttons until dn BRINE appears. Press NEXT to go to Step 6CS.
Press REGEN to return to previous step.
Do not use UP BRINE on a WS1.25CC.
Summary of Contents for WS1.25CC
Page 2: ......
Page 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Page 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Page 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Page 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Page 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Page 53: ...WS1CC WS1 25CC Manual Page 53...
Page 54: ...Page 54 WS1CC WS1 25CC Manual...
Page 55: ...WS1CC WS1 25CC Manual Page 55...
Page 56: ...Page 56 WS1CC WS1 25CC Manual...
Page 57: ...WS1CC WS1 25CC Manual Page 57...
Page 58: ...Page 58 WS1CC WS1 25CC Manual...
Page 59: ...WS1CC WS1 25CC Manual Page 59...