STEP 4
–
REGENERATION HOUR:
The manufacturer has factory set 2:00 A .M .
as the default . This is the hour of day for regeneration and can be reset
by using
+
or
—
buttons . “AM/PM” toggles after 12 . The default time is
2:00 a .m . (recommended for a normal household) . Press
next
to go to
step 5 . Press
regen
if you need to return to the previous step .
STEP 5
–
REGENERATION MINUTES:
Set the minutes using
+
or
—
buttons .
Press
next
to go to step 6 . Press
regen
to return to previous step .
To initiate an immediate manual regeneration, press and hold the
regen
button for three seconds . The system will begin to regenerate
immediately . The control may be manually stepped through the
regeneration cycles by pressing
regen
.
STEP 6
–
ALARM BUZZER:
The manufacturer has factory set “ON” as the
default . Alarm will sound immediately after regeneration if there is no salt
or if another error has occurred . Turn the alarm “OFF” or “ON” using
+
or
—
buttons . Press
next
to exit installer programming .
STEP 7
–
DISPLAY BACKLIGHT:
The manufacturer has factory set “ON” as the
default . Turn the light “OFF” or “ON” using
+
or
—
buttons . “OFF”
will turn display backlight off after five minutes of keypad inactivity .
Press
next
to exit installer programming .
REGEN TIME HOUR
SET
2:00
AM
REGEN TIME MINUTES
SET
2:00
AM
LIGHT NORMALLY
SET
ON
4
2
5
7
ALARM BUZZER
SET
ON
6
DAYS BETWEEN REGEN
SET
6
WATER HARDNESS
SET
20
GR
1
2
3
OPERATING DISPLAYS AND INSTRUCTIONS
1
TIME OF DAY
MON
GPM
2:40
8
PM
FLOW RATE
GPM
8.0
The user can scroll
between the displays
as desired .
1 .
GENERAL OPERATION:
When the system is operating, one of four displays may be shown . Pressing
next
will alternate
between the displays .
1 .
CURRENT TIME OF DAY
and
GPM
2 .
FLOW RATE
which is the current treated water flow rate through the system in Gallons Per Minute
3 .
CAPACITY REMAINING
which is the gallons that will be treated before the system signals a regeneration cycle
4 .
DAYS TO A REGEN
is the number of days left before the system goes through a regeneration cycle, based on
the days override value