 7.   Control valve does not 

regenerate automatically 

but 

does

 when the 

correct button(s) is 

depressed and held. 

For timeclock valves the 

buttons are 

t

.  

For all other valves the 

button is REGEN.

 A . Bypass valve in bypass position

 A .  Turn bypass handles to place bypass in  

service position

 B .  Meter is not connected to meter connection on 

PC board

 B .  Connect meter to three pin connection labeled 

METER on PC board

 C . Restricted/stalled meter turbine

 C .  Remove meter and check for rotation or  

foreign material

 D . Incorrect programming

 D . Check for programming error

 E .  Meter wire not installed securely into three  

pin connector

 E .  Verify meter cable wires are installed securely 

into three pin connector labeled METER

 F . Defective meter

 F . Replace meter

 G . Defective PC board

 G . Replace PC board

 8.  Hard or untreated 

water is being 

delivered

 A . Bypass valve is open or faulty

 A . Fully close bypass valve or replace

 B . Media is exhausted due to high water usage

 B .  Check program settings or diagnostics for 

abnormal water usage

 C . Meter not registering

 C .  Remove meter and check for rotation or  

foreign material

 D . Water quality fluctuation

 D .  Test water and adjust program  

values accordingly

 E .  No regenerant or low level of regenerant in 

regenerant tank

 E . Add proper regenerant to tank

 F . Control fails to draw in regenerant

 F . Refer to Troubleshooting Guide number 12

 G . Insufficient regenerant level in regenerant tank

 G .  Check refill setting in programming . Check 

refill flow control for restrictions or debris and 

clean or replace

 H . Damaged seal/stack assembly

 H . Replace seal/stack assembly

 I .  Control valve body type and piston type  

mix matched

 I .  Verify proper control valve body type and  

piston type match

 J . Fouled media bed

 J . Replace media bed

 9.  Control valve uses too 

much regenerant

 A . Improper refill setting

 A . Check refill setting

 B .  Improper program settings

 B .  Check program setting to make sure  

they are specific to the water quality and 

application needs

 C . Control valve regenerates frequently

 C .  Check for leaking fixtures that may be 

exhausting capacity or system is undersized

 10.  Residual regenerant 

being delivered to 

service

 A . Low water pressure

 A .  Check incoming water pressure – water 

pressure must remain at minimum of 25 psi

 B . Incorrect injector size

 B .   Replace injector with correct size for  

the application

 C .  Restricted drain line

 C .  Check drain line for restrictions or debris  

and clean

 11.  Excessive water in 

regenerant tank

 A .  Improper program settings

 A . Check refill setting

 B . Plugged injector

 B . Remove injector and clean or replace

 C . Drive cap assembly not tightened in properly

 C . Retighten the drive cap assembly

 D . Damaged seal/stack assembly

 D . Replace seal/stack

 E . Restricted or kinked drain line

 E .  Check drain line for restrictions or debris and 

or unkink drain line

 F . Plugged backwash flow controller

 F .  Remove backwash flow controller and clean  

or replace

 G . Missing refill flow controller

 G . Replace refill flow controller

 PROBLEM 

CAUSE 

CORRECTION 

14

TROUBLESHOOTING GUIDE 

cont’d:

Summary of Contents for Impression Series

Page 1: ...Impression Series and Impression Plus Series Water Filters For Models IMBF IMBF MAN IMAN IMAF MGS IMS IMB IAG IACG AN IMPBF IMPBF MAN IMPAF MGS IMPS IMPB IPAG IPACG AN...

Page 2: ...y this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions regarding your water conditioner contact your...

Page 3: ...ow Rate Capacity Remaining and Days to a Regeneration are optional displays but are not normally used Each of these can be viewed by pressing next to scroll through them When stepping through any prog...

Page 4: ...regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is iso...

Page 5: ...10 feet of piping between its outlet and the inlet of a water heater CAUTION To protect the unit in the event of a hot water heater backup the manufacturer recommends the use of an expansion tank on t...

Page 6: ...line flow control fitting and solder joints Failure to do this could cause interior damage to the flow control Backwash of an automatic filter can be directed into a septic tank in most cases but beca...

Page 7: ...neration which comes into contact with the chlorine pellets dissolves them and is then drawn into the filter to disinfect the system periodically and then safely rinsed away We recommend the use of pe...

Page 8: ...ny number is set allowable range from 1 to 28 a regeneration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration Set Day Override...

Page 9: ...and holding the regen button for three seconds while in the Backwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The system is...

Page 10: ...out salt To initiate a manual regeneration at the next preset regeneration time press and release regen The words REGEN TODAY will flash on the display to indicate that the system will regenerate at t...

Page 11: ...tank just prior to regeneration this comes in contact with the chlorine pellets dissolves them and is drawn into the filter to disinfect the system periodically We recommend the use of pellets manufac...

Page 12: ...Pay close attention to media level when filling Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bottom see diagram Once the...

Page 13: ...stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into thr...

Page 14: ...tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Control valve body ty...

Page 15: ...on or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGE...

Page 16: ...conds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wire not connecte...

Page 17: ...pression cover 1 CV3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3579WI PC board CC 1 5 CV3110 Drive gear...

Page 18: ...1 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4...

Page 19: ...3148 Bypass rotor seal retainer 2 8 CV3152 O ring 135 2 9 CV3155 O ring 112 2 10 CV3156 O ring 214 2 BRINE ELBOW ASSEMBLY Item No Part No Description Qty 1 CV3195 01 Refill port plug assembly 1 2 CH46...

Page 20: ...mbly blue CV3010 1G G injector assembly yellow CV3010 1H H injector assembly green CV3010 1I I injector assembly orange CV3010 1J J injector assembly light blue CV3010 1K K injector assembly light gre...

Page 21: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Page 22: ...us positions on the valve is available to aid in assembly or disassembly SERVICE WRENCH CV3193 02 22 CHLORINE TANK ASSEMBLY Item No Part No Description Qty 1 CH4600 50 474 safety float valve 1 2 CH464...

Page 23: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...

Page 24: ...CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut...

Page 25: ...d Greensand Greensand Amount Cu Ft 1 0 1 5 2 5 Gravel Amount Size No 1 14 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 20 7 lb 20 Continuous Flow GPM 4 0 4 0 6 0 P...

Page 26: ...2 0 Calcite 0 5 Calcite 0 75 Calcite 1 0 Gravel Amount Size No 1 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 14 lb 1 4 x 1 8 21 lb 1 4 x 1 8 21 lb 1 4 x 1 8 Gravel Amount Size No 2 7 lb 20 7 lb 2...

Page 27: ...mponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent mann...

Page 28: ...displays will be shown time of day gallons of treated water available or gallons per minute Pressing next will toggle between the three choices TO SET TIME OF DAY In the event of a prolonged power ou...

Reviews: