Impression Plus Series
®
Metered Water Softeners
For Models:
• IMP-844• IMP-948• IMP-1044• IMP-1054• IMP-1248• IMP-1354
For Cabinet Models:
• IMPC-835• IMPC-935• IMPC-1035
Page 1: ...Impression Plus Series Metered Water Softeners For Models IMP 844 IMP 948 IMP 1044 IMP 1054 IMP 1248 IMP 1354 For Cabinet Models IMPC 835 IMPC 935 IMPC 1035...
Page 2: ...ome when installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any ques...
Page 3: ...kly exit any Programming Installer Settings etc press SET CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the prese...
Page 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...
Page 5: ...liers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 30 100...
Page 6: ...lamp or jumper wiring NOTE If replacing an existing softener also replace the ground clamps wire If removing a softener replace the piping with the same type of piping as the original to assure plumbi...
Page 7: ...ilding structure Your softener is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow In the event of a malfunction however an overflow line connec...
Page 8: ...DNESS Set the amount of hardness in grains per gallon default 20 using the or buttons The allowable range is from 1 to 150 in 1 grain increments Note Increase the grains per gallon if soluble iron is...
Page 9: ...nd display shows the current treated water flow rate through the system in Gallons Per Minute The third display is one of the following days remaining or volume remaining Days remaining is the number...
Page 10: ...thereafter see Start Up Instructions for regeneration sequence the water softener will deliver water but it will be untreated IMPORTANT With the Dry Salt Storage Feature the brine tank will refill 4 h...
Page 11: ...er softener include a dry salt storage feature no water in brine tank between regeneration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use...
Page 12: ...up it could result in a salty water complaint after the first regeneration During the first regeneration the unit will draw out the initial volume of brine regenerant and refill it with the correct pr...
Page 13: ...any remaining debris and air from the system again 1 Full open a cold water faucet preferably at a laundry sink or bathtub without an aerator 2 Wait two to three minutes or until water runs clear then...
Page 14: ...ed stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are installed securely into t...
Page 15: ...in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Contro...
Page 16: ...t power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and REGEN buttons for 3...
Page 17: ...ttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP motor wir...
Page 18: ...pression cover 1 CV3540P A Black Impression Plus cover 1 CV3540P W A Gray Impression Plus cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3579WI PC board CC 1 5 CV3110 Drive gear...
Page 19: ...11 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4...
Page 20: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...
Page 21: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...
Page 22: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...
Page 23: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve...
Page 24: ...24 x 40 BT s 1 5 CH1018 2 piece overflow set 1 6 CH4500 48 474 air check assembly 1 2 x 48 1 7 CH4640 32 474 float assembly 32 w 2 grommets 1 8 CH4600 50 474 safety brine valve w 5 gpm glow control 1...
Page 25: ...ion Qty 1 CG2197 01 Salt and tank cover must be ordered together 1 2 CG2724HP 01 Windsor cabinet white with black lids 1 3 CH1090 01 Optional salt grid for 8 diameter tank and 4 brine well 1 CH1090 02...
Page 26: ...51 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connec...
Page 27: ...3375 Fitting 2 1 BRASS SHARK BITE Item No Part No Description Qty CV3007 13 1 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2...
Page 28: ...ssure Loss at Max Service PSI 8 6 14 1 15 0 Min to Max Working Pressure PSI 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1...
Page 29: ...mponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent mann...
Page 30: ...30 NOTES...
Page 31: ...31...
Page 32: ...s as shown to the right Access this mode by pressing NEXT and button simultaneously NOTE Hardness display shows nA if used as a filter If other displays do not appear refer to manual QUICK REFERENCE G...