24
25
SPECIFICATIONS
1
All Sanitizer Plus water conditioners are pre-factory set at medium salting.
NOTE: Influent waters must be at least 3 GPG hardness and 80 TDS. A calcite or corosex unit may be needed for correct operation.
2
Combined iron and manganese removal varies depending on the form of iron, manganese, pH and other local conditions.
On waters that are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form that are too fine
to be filtered.
3
The pH listed is the minimum for the infl uent water.
4
Op� mum pH adjustment occurs at 3.0 gpm or less at maximum salt se� ngs. Higher fl ow rates will produce less pH adjusted water.
5
Unit not tested for capacity at these fl ow rates. Water quality may vary.
CYCLE TIMES AND USAGE
Sanitizer Plus Series
®
Specifications
Manufactured by Water-Right, Inc. • 1900 Prospect Court • Appleton, WI 54914 • 800-777-1426 • water-right.com
S
PE-SAN PLUS RevA0821
MODEL
ASP1-1044
ASP1-1054
ASP1-1354
ASP2-1044
ASP2-1054
ASP2-1354
1
Capacity:
(Grains/Lbs. NaCl)
Minimum
7,300 @ 3.2
16,400 @ 6.1
28,300 @ 9.5
11,100 � 3.2
22,900 � 6.1
28,200 � 9.3
Medium
11,400 @ 9.3
20,700 @ 12.4
33,600 @ 15.9
19,100 � 9.3
32,000 � 12.4
48,300 � 15.9
Maximum
11,800 @ 12.4
22,600 @ 15.9
36,900 @ 21.2
20,300 � 12.4
34,800 � 15.9
60,300 � 26.5
Amount of Media (Cu.Ft.)
1.0
1.5
2.5
1.0
1.5
2.5
Maximum Water Hardness (GPG)
20
30
40
40
60
80
2
Maximum Iron and Manganese (PPM)
8.0
10.0
15.0
8.0
10.0
15.0
3
Minimum pH
6.5
6.0
6.0
7.0
7.0
7.0
4
Total pH Adjusted Water
510
510
863
N/A
N/A
N/A
5
Peak Flow Rate (GPM @ P-PSI)
19.0 @ 8.3
17.0 @ 7.8
19.0 @ 7.6
19.0 @ 9.3
17.0 @ 9.1
19.0 @ 8.6
Con� nuous Flow Rate (GPM @ P-PSI)
9.0 @ 2.4
9.0 @ 2.8
9.0 @ 2.7
9.0 @ 3.0
8.0 @ 3.7
9.0 @ 2.8
Water Pressure Range (PSI)
25-100
25-100
25-100
25-100
25-100
25-100
Water Temp. (ºF)
33-100
33-100
33-100
33-100
33-100
33-100
Electrical Requirements (volts-hertz)
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
Pipe Size
1”
1”
1”
1”
1”
1”
Total Dimensions:
Media Tank
10”W x 52”H
10”W x 62”H
13”W x 62”H
10”W x 52”H
10”W x 62”H
13”W x 62”H
Brine Tank
18”W x 33”H
18”W x 33”H
18”W x 40”H
18”W x 33”H
18”W x 33”H
18”W x 40”H
ASP1/ASP2 SPECIFICATIONS
MODEL
ASP1-1044
ASP1-1054
ASP1-1354
ASP2-1044
ASP2-1054
ASP2-1354
MIN .
GAL .
MIN .
GAL .
MIN .
GAL .
MIN .
GAL .
MIN .
GAL .
MIN .
GAL .
Brine Refill
6
3
10
5
12
6
6
3
10
5
12
6
The above sequence takes place prior to regeneration; therefore, minutes are not included in totals
Backwash
12
38
12
50
12
90
12
38
12
50
12
62
Brine & Rinse
72
29
90
36
90
72
72
29
90
36
90
72
Rapid Rinse
4
13
4
17
4
30
4
13
4
17
4
21
Total
88
80
106
103
106
192
88
80
106
103
106
155
Width
Height