Water Mist WM-A1584 Installation, Operation And Maintenance Manual Download Page 2

Watermist Fire Technologies

Page 2

Contents

1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.  Warning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

IMPORTANT NOTE ON BATTERIES:  . . . . . . . . . . . . . . . 3

3.  General Description  . . . . . . . . . . . . . . . . . . . . . . . . 4
4.  Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.  Termination List. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6.  Adjustments and Indications  . . . . . . . . . . . . . . . . . . 6
7.  Installation Procedure  . . . . . . . . . . . . . . . . . . . . . . . 7

Enclosure/Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Earthing Arrangement.  . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cable Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

9.  Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Commissioning Procedure. . . . . . . . . . . . . . . . . . . . . . . 8

Summary of Contents for WM-A1584

Page 1: ...1320 fax 01525 285864 Water Mist Fire Technologies Ltd Unit 5 Youngs Industrial Estate Stanbridge Road Leighton Buzzard Bedfordshire LU7 4QB WM A1584 10 AMP POWER SUPPLY WM A1584 10 AMP POWER SUPPLY I...

Page 2: ...arning 3 IMPORTANT NOTE ON BATTERIES 3 3 General Description 4 4 Specification 5 5 Termination List 5 6 Adjustments and Indications 6 7 Installation Procedure 7 Enclosure Housing 7 Earthing Arrangemen...

Page 3: ...data WARNING If required clean the case of the battery with a cloth that has been soaked or dampened with distilled water Do not use organic solvents such as petrol paint thinners benzene or mineral s...

Page 4: ...8 volt output is derived from the DC output of the switchmode power supply whilst the 5v DC output is derived via a regulator on the WM A1584 controller board In the event of Mains failure the power s...

Page 5: ...584 a delay of 3 seconds is initiated and if the fault still exists after this delay period the Common Fault output CF is activated Note 3 When a fault associated with the Mains input is detected by t...

Page 6: ...ated 5 8V Fault Amber Flashes whenever 5v DC regulator output is above 9v DC and below 4v DC MAIN Mains input fault Amber Flashes whenever the DC input from the switch mode unit falls below 28v DC or...

Page 7: ...ich can incorporate 2 x 12v rechargeable Lead Acid Batteries The power supply should be mounted on to a metal chassis or back plane using the 5 o M5 x 20mm bolts provided Figure 1 provides information...

Page 8: ...convection for cooling purposes it is important that the enclosure is checked sited in a position with a free ow of air This also applies to equip ment tted with cooling fans 6 Connect the A C mains s...