To test the power pack, use a voltmeter set on the cor-
rect voltage (120V or 240V). Place one of the voltmeter
leads into the lamp plug where the white wire goes into it
and plug the other voltmeter lead into the lamp plug where
the blue wire goes into it. If no voltage is present replace
the ozone ballast (Part #6-05231 - 120V, Part #6-05232
- 240V). When ordering an ozone ballast, you also need
the 4-pin connector (Part #6-05233).
Replacing the lamp: (See Ozone Generator Break-
down)
Lamp replacements are available from your
Water Maze
Dealer should they need to be replaced. Simply turn off
the power to the CLP at the breaker, remove the screws
on the power pack cover and remove the cover. Discon-
nect the plug on the end of the ozone lamp. Now, loosen
the lamp holder locking ring from around the end of the
lamp by turning it counterclockwise and remove it. Re-
move the lamp by grabbing the rubber bushing around
the end of the lamp and pulling it straight out. Remove
OZONE GENERATOR
TESTING
Four Pin
Connector
Ballast
Ozone Lamp
Prongs
the rubber bushing from the lamp and install it on your
new lamp, making sure the outer edge of the bushing is
flush with the outer edge of the silver end cap on the
lamp. Now, slide the lamp back into the reaction cham-
ber. The lamp holder may now be reinstalled and tight-
ened. Reinstall the plug onto the lamp and replace the
power pack cover. Caution: Keep the lamp free of fin-
gerprints and dust particles by only handling the metal
end caps on the lamp. You can clean the lamp with rub-
bing alcohol and a soft cloth. A dirty lamp will not allow
maximum ozone output.
SPECIFICATIONS:
Energy Required 110V: 105VAC MIN., 125VAC MAX.,
.800 AMP/Ballast
Energy Required 220V: 210VAC MIN., 230V MAX.,
.450AMP/Ballast
Power Consumption: 20 Watts
Average Lamp Life: 9,000 Hours