DANGER: Elements should only be replaced with an element of the same power rating
that was factory installed, and corresponds to the rating label on the unit.
NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code. Refer to
wiring diagrams in this manual for field wiring connections.
Branch Circuit Sizing and Wire Size Guide
Single Phase
Wiring
Total Water
Heater Wattage
Recommended Over Current
Protection Copper (fuse or circuit
breaker amperage rating)
Wire Size AWG Based on N.E.C.
Table 310-16 (75°C)
120V
240V
120V
240V
2,000
20
----
12
----
3,000
----
20
----
12
3,800
----
20
----
12
4,500
----
25
----
10
11