background image

15

ENVISION POOL HEATER INSTALLATION MANUAL

Warranty

W

a

terFurnac

e Int

ernational, Inc.

9000 C

onserv

ation W

a

y

F

ort W

a

yne

, IN 46809-9

7

94

US

A

V

isit us at 

w

a

terfurnac

e

.c

om

UNIT SERIAL NUMBER

THIS W

ARRANTY GIVES Y

OU SPECIFIC LEGAL RIGHT

S.

LIMITED W

ARRANTY CERTIFICA

TE

O

WNER

ADDRES

S

CITY

/

S

T

A

TE/

ZIP

INS

T

ALLA

TION D

A

TE

C

ONTRA

CT

OR

ADDRES

S

CITY

/

S

T

A

TE/

ZIP

IN-GROUND MODEL NUMBER

A. W

ARRANTY

 

W

a

terFurnac

e Int

ernational, Inc. (WFI) w

arr

ants, t

o the original o

wner

,  the heat pump pool heat

er t

o be 

fr

ee fr

om manuf

acturing def

ects f

or a limit

ed t

en (10) y

ear t

erm as f

ollo

w

s: T

w

o (2) y

ears full parts, y

ears 

thr

ee (3) thr

ough t

en (10) the c

ompr

es

sor and heat e

x

changer (parts only). T

his w

arr

anty does not include 

tr

ansportation char

ges f

or equipment or c

omponent parts t

o or fr

om the f

act

ory

. T

his w

arr

anty is v

alid only 

in the C

ontinental U

.S.

B. 

EFFECTIVE D

A

TE OF W

ARRANTY

 

Is the dat

e of ins

tallation, if pr

operly document

ed, otherwise the dat

e of shipment plus thr

ee (3) months.

C. C

ONDITIONS

 

A)

 Malfunction or damage r

esulting fr

om ins

tallation, oper

ation, maint

enanc

e

, v

oltage c

onditions, or servic

not in ac

c

or

danc

e with WFI specifi

 cations. 

B)

 Malfunction due t

o the f

ailur

e t

o perf

orm normal maint

enanc

as outlined in the Ins

tallation Manual. 

C)

 Malfunction or damage due t

o c

onditions not int

ended f

or original 

use of the unit. 

D)

 Malfunction or damage due t

o negligenc

e

, abuse

, fr

ee

zing c

onditions, ac

cident, or acts 

of God. 

E)

 Malfunction of damage fr

om plants or animals. 

F)

 Malfunction or damage fr

om the attachment 

of ac

c

es

sories not authoriz

ed b

y WFI. 

G)

 Unnec

es

sary servic

e calls due t

o err

oneous oper

ational r

eports, 

maint

enanc

e and electrical servic

e

H)

 Units sold outside the c

ontinental Unit

ed Stat

es. 

D

SER

VICE PERFORMED WITHIN THE W

ARRANTY PERIOD

 

Mus

t be appr

o

v

ed b

y WFI PRIOR t

o servic

e being perf

ormed, and mus

t be perf

ormed b

y a qualifi

 ed 

technician. 

T

he w

arr

anty is v

oid if the unit is r

epair

ed b

y an

y unqualifi

 ed t

echnician. R

eimbursement f

or r

eplac

ement parts 

or r

epair servic

es that ar

e not authoriz

ed or perf

ormed b

y WFI ar

e not c

o

v

er

ed under this limit

ed w

arr

anty

E. W

ARRANTY 

P

ART

S

 

W

ill be r

eplac

ed or r

epair

ed at the discr

etion of WFI. Shipping of w

arr

anty parts is not included. Def

ectiv

parts mus

t be pr

operly fi

 eld scr

apped. WFI is not liable f

or the labor in

v

olv

ed in the unauthoriz

ed r

epair

or r

eplac

ement c

os

ts including parts and labor

. T

his w

arr

anty is in lieu of all other w

arr

anties, e

xpr

es

sed or 

implied, writt

en or or

al. T

he liability of WFI shall not e

x

c

eed the c

os

t of the r

epair or r

eplac

ement of def

ectiv

parts. WFI is not liable f

or damages of an

y sort whatsoe

v

er

, including incidental and c

onsequential. T

her

e ar

no implied w

arr

anties of fi

 tnes

s f

or a particular purpose that apply t

o this pr

oduct. 

LIMITED

2 YEAR P

ART

S

10 YEAR C

OMPRES

SOR

& HEA

T EX

CHANGER

Pool Heat

er 

04

/

13

Summary of Contents for Envision

Page 1: ...Installation Information Water Piping Connections Chemical Use Electrical Startup Procedures Preventive Maintenance Troubleshooting IM1009PN 04 13 Envision Pool Heater Installation Manual Pool Heater...

Page 2: ......

Page 3: ...llation 5 Dimensional Data 6 Physical Data 6 Water Flow and Connections 7 Chemical Use 7 Electrical Connections 8 Electrical Data 8 Electronic Control Panel 9 Modes of Operation 9 Wiring Schematic 10...

Page 4: ...T Titanium Rev 18 April 2013D Performance Data Model GPM High Ambient Low Ambient EWT 80 F EAT 80 6 70 7 F EWT 80 F EAT 50 44 2 F Capacity BTUH COP Capacity BTUH COP 0750 22 50 000 6 0 31 000 4 0 110...

Page 5: ...consumes in electrical power In addition it will still warm your pool even as outdoor temperatures drop into the 40s The information in this manual was prepared to assist in the proper installation o...

Page 6: ...0 32 9 24 5 38 0 26 0 2 ID PVC UNION 1100 1750 32 9 32 5 38 0 34 0 2 ID PVC UNION 04 11 13 NOTE All dimensions are in inches Physical Data Model 0750 1100 1250 1500 1750 Compressor Reciprocating Scrol...

Page 7: ...ain Skimmer Check Valve Chlorine Gas Trap Ball Valves Filter Pump In Out Heat Pump Pool Heater Heat Pump Pool Heater In Out Pump Filter From Main Drain Skimmer Return Ball Valve For Flow Rates Greater...

Page 8: ...ht seal extending the life of the heater 4 Attach grounding conductor to the ground lug provided inside the electrical control enclosure 5 Install L1 and L2 input conductors to the input lugs of the c...

Page 9: ...inal strip and install the remote control system The mode jumper must be on pins 3 4 for this mode of operation See the Terminal Strip and Mode Configuration Pins illustration for pin settings 4 3 2 1...

Page 10: ...Remote Automation Microprocessor Control TEST PIN CC HP LP DC WT FS1 FS2 Field Installed Flow Switch See Table 1 Remote Automation Jumper P1 P2 P3 PIN 1 2 3 Field Installed home automation control See...

Page 11: ...conductive A pool cover solar blanket may reduce initial heating time by up to 50 Defrost Cycle The heat pump pool heater has automatic defrost When the outdoor temperature drops below 40 F frost may...

Page 12: ...breakers or replace fuses if necessary 2 Check to be sure the electronic control panel is set properly The unit must be in either the POOL or SPA mode and the desired temperature must be set above th...

Page 13: ...13 ENVISION POOL HEATER INSTALLATION MANUAL Notes...

Page 14: ...e By 4 Added Nomenclature 19 Apr 2013 DS 4 Added Performance Data 19 Apr 2013 DS 6 Added Dimensional and Physical Data 19 Apr 2013 DS 8 Updated Electrical Data 19 Apr 2013 DS 15 Added New Warranty 19...

Page 15: ...of the unit D Malfunction or damage due to negligence abuse freezing conditions accident or acts of God E Malfunction of damage from plants or animals F Malfunction or damage from the attachment of a...

Page 16: ......

Page 17: ...llation Do not mail the warranty certi cate Mail To WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 Fax To 800 934 9934 Is Pool Covered Yes No Circle One Is Pool Screened...

Page 18: ......

Page 19: ......

Page 20: ...l Inc 9000 Conservation Way Fort Wayne IN 46809 www waterfurnace com 2013 WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 WaterFurnace has a policy of continual product r...

Reviews: