31
5 SERIES 500A11 INSTALLATION MANUAL
Add On Control Feature Kits
(field or factory Installed)
Description
Aurora ‘Base’
Aurora ‘Advanced’
Geo Energy Monitoring Kit
Monitors realtime power consumption of compressor, blower, aux
heat and pump. Requires thermostat TPCM32U03, TPCM32U04,
or TPCC32U01. AXB required.
-
Standard
Refrigeration Monitoring Kit
Monitors realtime pressures, temperatures, superheat, and
subcooling. AXB required.
-
Optional Sensor Kit
Performance Monitoring Kit
Monitors air and water temperatures, and water flow rate and
calculates heat of extraction/rejection. AXB required.
-
Optional Sensor Kit
Data Logging (AWL) Kit
Allows data logging of up to 12 months. AXB required. Can
also be temporarily installed.
-
Optional
HAN/Smart Grid Com
(AWL and Portal) Kit
Allows direct communication of the Aurora to Smart Meters,
HAN, and internet. AXB required.
-
Optional
AXB Kit
for advanced hot water
generator control, slaving, variable
speed pump, IntelliZone2
Added to 5 Series for key features of advanced hot water
generator control, advanced loop control/slaving, IntelliZone2
communication, and variable speed pump control.
Optional
(field Kit)
Standard
Add On Thermostats and Zoning
Description
Aurora ‘Base’
Aurora ‘Advanced’
TP32U03/04 - MonoChrome
Traditional Y1, Y2 Thermostat
Elite Stat with full English fault codes and alerts, traditional
Y1, Y2 thermostat
Optional
Optional
TP32S01/02 -
Traditional Y1, Y2 Thermostat
Traditional Y1, Y2 thermostat
Optional
Optional
TPCM32U03/04 - MonoChrome
Communicating Thermostat
Elite Stat with full English fault codes and alerts,
communicating thermostat. Monochrome thermostat allows
instantaneous energy measurement only
Optional
Optional
TPCC32U01 - Color Touchscreen
Communicating Thermostat
4.3 in. color touchscreen communicating thermostat with
full English fault codes and alerts. Color thermostat allows
instantaneous energy measurement and 13 month energy
usage history.
Optional
Optional
IntelliZone
®
Zoning Compatibility
IntelliZone
®
is a non-communicating zoning system requiring
Y1, Y2 signals and controls the ECM blower motor directly.
Optional
(ECM Preferred)
Optional
(IntelliZone2
Preferred)
IntelliZone2
®
Zoning
IntelliZone2
®
is a communicating zoning system that includes
color main thermostat and up to 6 zones (with variable
speed), 4 zones (with dual capacity), and 2 zones (with
single speed). There are 3 thermostat options (MasterStat,
SensorStat, ZoneStat). Requires AXB.
-
Optional
(IntelliZone2
Preferred)
Service Device
Description
Aurora ‘Base’
Aurora ‘Advanced’
Aurora Interface and Diagnostics
(AID) Tool
Allows setup, monitoring and troubleshooting of any
Aurora Control.
NOTE:
Although the ABC has basic compatibility with all
Aurora, new product features may not be available on older
AID Tools. To simplify the basic compatibility ensure the
version of AID is at least the same or greater than the ABC
software version.
For Service
(Ver. 1.xx or greater)
For Service
(Ver. 2.xx or greater)
The Aurora Control System cont.