Start-Up Procedure 

1.  Fill the mineral tank with water 



Keep NitraMAX in BYPASS 



Press and hold the extra cycle button for 5 seconds, display will indicate BW, Backwash 

cycle.  



Push extra cycle button once and let go, display will indicate BD, Brine Draw cycle.  



Push extra cycle button again and let go, display will indicate RR, Rapid Rinse cycle.  



Slowly open bypass valve and allow water to flow for 2-4 minutes. This will allow the 

media in the tank to become saturated. 



Open bypass valve to the service position.  



Push extra cycle button once and let go, display will indicate BF, Brine Fill cycle. 



Allow timer to fill the brine tank for the entire time on the display. The unit will advance 

to the service position when completed. 



Push extra cycle button for 5 seconds, this will start a manual regeneration from start-to-

finish. This will take approximately two hours.  

Start-up procedure is now complete. 

 

The unit is now pressurized with water and ready for service

.  

 

Proceed to setting current time of day.

 

Placing unit into service 

Normal 

Operation 

Mode Icon 



While in service, the Data Display alternates between time of day, 
volume remaining or days to regeneration. 



The Flow Indicator flashes when outlet flow is detected. 



The Faucet Icon flashes if a regeneration cycle has been queued. 

Summary of Contents for Brassmaster Plus+ NitraMAX Series

Page 1: ...e paid test bottles included To reorder visit watercontrolinc com nitramax nitrate removal or scan this QR code BrassMaster and BrassMaster Plus Technical Video Library https watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control module If replacing your control module please use the downloadable M...

Page 2: ...etpoints are established based on water hardness levels unless combined ni trate nitrite levels exceed 50 PPM mg L If nitrate nitrite levels exceed 50 PPM please con tact Water Control Corporation for proper system setpoints Specifications NM 75 NM 125 Softening capacity grains 24 000 40 000 Cation softening media cu ft 0 75 1 25 Nitrate Nitrite Sulfate capacity raw water PPM or mg L 100 100 Anion...

Page 3: ...ain line fitting and run to a nearby drain IMPORTANT It is highly recommended that a hose clamp be used to secure tubing to drain fitting to ensure tubing from being removed during elevated pressure situations Be sure not to submerse drain line end into drain as an 1 1 2 minimum air gap must be maintained to prevent potential backflow hazard Firmly secure at drain while maintaining a minimum 1 1 2...

Page 4: ...and let go display will indicate BF Brine Fill cycle Allow timer to fill the brine tank for the entire time on the display The unit will advance to the service position when completed Push extra cycle button for 5 seconds this will start a manual regeneration from start to finish This will take approximately two hours Start up procedure is now complete The unit is now pressurized with water and re...

Page 5: ...egeneration periods In areas where nitrates range between 0 50 PPM this setting should not exceed 6 days If nitrate lev els exceed 50 PPM please contact Water Control for a setpoint recommendation Setting Current Time Day 1 Press either the Up or Down button to adjust current time of day by one digit Press and hold either the up or down button to adjust current time of day display by several digit...

Page 6: ...r Gal lon to this setting This will determine the amount of water usage allowed between regenera tion cycles NOTE If combined Nitrate Nitrite levels exceed 50 PPM contact Water Con trol for additional setpoint instructions 5 Set Fixed Reserve Capacity Press the Extra Cycle button to advance to next option Set the Fixed Reserve Capacity for the household This is the amount of water needed in reserv...

Page 7: ...n from forming which will not allow the NitraMAX to regenerate properly The NitraMAX will regenerate but not recondition the media A salt bridge can be broken up using a broom handle or similar rod Carefully pound it into the salt and the pellets will collapse After loosening the salt pellets wait 2 hours and start a manual regeneration A second system regen eration may be needed to fully recondit...

Page 8: ... FITNESS FOR A PARTICULAR PURPOSE WHAT IS NOT COVERED BY THESE WARRANTIES 1 Conditions damages and health effects resulting from any of the following Wear or malfunction caused by unfavorable water conditions Improper installation delivery or maintenance Any repair modification alteration or adjustment not authorized by the manufacturer or an authorized servicer Misuse abuse accidents or unreasona...

Reviews: