background image

6

Additional Parts required.

Typical Remote Installation

Hard Water Line

FIG. 5

Outside Faucet

(Hard Water)

Soft, Cold Water

Soft, Hot

Water

Outside Faucet

(Hard Water)

Water

Heater

Shutoff

Valve

Water

Softener

Reverse Osmosis

Drain

Soft water

to Reverse

Osmosis

System

Hard

Water to

House

Main

Shutoff

Valve

Storage

Tank

Water

Meter

Reverse Osmosis

System

To Faucet

Floor

Drain

Air

Gap

(see

p. 11)

Typical Under Sink Installation

All install parts included in package

.

Plan Your Installation

FIG. 4

Storage

Tank

Sink Drain P-Trap

Shutoff Valve

Reverse

Osmosis

Assembly

HOT    COLD

Cold Water

Supply

Drain Adapter

for Reverse

Osmosis

Waste Water

Summary of Contents for EcoPure ECOP30

Page 1: ...2 58 See performance data on pages 27 28 for details If you have any questions or concerns when installing operating or maintaining your reverse osmosis system call our toll free number 1 800 693 1138...

Page 2: ...ing 8 Step B Install Reverse Osmosis Drain 9 10 Step C Install Reverse Osmosis Filter Assembly 11 Step D Install Storage Tank 11 Step E Install Reverse Osmosis Faucet 12 13 Step F Connect Tubes 14 15...

Page 3: ...er the system This system is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts Arsenic Reduction This system shall only be used for arsenic reduction...

Page 4: ...r Reverse Osmosis Drinking Water System is shipped complete in one carton Remove all items from your shipping carton Check all items against the packing list below Note any items lost or damaged in sh...

Page 5: ...point is needed for drain water from the Reverse Osmosis system REMOTE INTERIOR LOCATION The Reverse Osmosis Filter Assembly and storage tank may also be installed in a remote interior location away...

Page 6: ...sis Drain Soft water to Reverse Osmosis System Hard Water to House Main Shutoff Valve Storage Tank Water Meter Reverse Osmosis System To Faucet Floor Drain Air Gap see p 11 Typical Under Sink Installa...

Page 7: ...d filter assembly into planned location Check position of items and space required for proper installation Ensure tubes may be routed without kinking 3 Remove tank and filter from planned location and...

Page 8: ...st provide a leak tight connection to the Reverse Osmosis 1 4 tubing Locate the cold water line in the sink cabinet It is recommended but not required that the cold water line be soft water Complete t...

Page 9: ...trap See Fig 9 Make sure that the Q C fitting is toward the direction of the RO faucet See Fig 10 NOTE Locate so that the drain tubing from the Reverse Osmosis faucet will run straight to the adaptor...

Page 10: ...e with an adequate length of tubing to reach the drain point Refer to Step F later in the manual on how to disconnect and connect tubing NOTE A flow control insert is located inside the elbow fitting...

Page 11: ...ur later in the assembly 4 Place the storage tank next to the Reverse Osmosis Assembly The tank can be placed upright or on its side INSTALL REVERSE OSMOSIS FILTER ASSEMBLY The Reverse Osmosis Filter...

Page 12: ...s adequate tube routing space between the faucet and filter assembly 4 If drilling is needed drill a 1 1 4 diameter hole in the mounting surface IMPORTANT Drilling holes into countertops and sinks sho...

Page 13: ...faucet barb fitting on faucet See Figs 17 20 21 D Pull on the tubing to be sure it is held firmly in the fit ting 6 Mount the faucet body onto the faucet base 1 4 turn FAUCET ELECTRONICS Inside the fa...

Page 14: ...collet until it engages the o ring See Fig 20 Continue pushing until the tube bottoms out against the back of the fitting See Fig 21 Do not stop pushing when the tube engages the o ring Failure to fo...

Page 15: ...way into the fitting See Figs 20 21 5 Pull on the tube to be sure it s held firmly in the fitting CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1 Locate the 3 8 black tube attached...

Page 16: ...e Figs 14 and 25 6 Sanitizing the system will be completed during the pressure test and purging steps on the following page NOTE The bleach must be removed from the system before drinking the water Se...

Page 17: ...and do not per mit the use of saddle valves If you live in the state of Massachusetts review plumbing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installa tion PURGING...

Page 18: ...stfilter before going to the Reverse Osmosis faucet See Fig 27 The postfilter is an activated carbon type filter Any remaining tastes and odors are reduced from the product water Clean high quality dr...

Page 19: ...to the storage tank 5 Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain 6 Faucet is activated 7 Processed water leaves the storage tank and flows to the post...

Page 20: ...the cartridge membrane and causes pin hole leaks It s time to replace the Reverse Osmosis cartridge when the pro duction rate and or quality of product water drops Product water may begin to taste di...

Page 21: ...and insert the o ring seal into the bottom of the port See Figs 30 31 3 Push the collet inward until it locks in place See Figs 30 31 ChANGE BATTERY To change battery complete the following steps 1 Re...

Page 22: ...ilter or Reverse Osmosis membrane cartridges plugged with sediment Correction Replace the prefilter cartridge If rate does not increase replace the postfilter cartridge and Reverse Osmosis membrane ca...

Page 23: ...ee pages 14 15 Cause Tubing nicked Correction Remove tube from connection Remove nicked portion by cutting tube to shorter length Reinsert in connection See pages 14 15 If removing the drain line leav...

Page 24: ...24 Exploded View 22 21 18 17 16 15 14 13 11 1 2 3 4 8 9 7 5 6 1 4 red tubing 12 10 8 20 23 19...

Page 25: ...utomatic Shutoff Kit incl Key No 7 4 of Key No 6 6 of Key No 5 5 Screw 6 req d 6 Washer 4 req d 7 Automatic Shutoff Cover Assembly 7333179 Diaphragm Kit includes Key Nos 9 10 2 of Key No 8 8 Diaphragm...

Page 26: ...xcept normal shipping and installation charges Labor to maintain the equipment is not part of the warranty Filters and membranes are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1...

Page 27: ...ur water supply See elsewhere in this owner s manual for further instructions on filter replacement system installation operating procedures and warranty The maintenance instructions must be followed...

Page 28: ...340 40 88 Sulfate7 800 10 2508 780 12 98 Tannin7 3 0 10 1 08 2 9 0 1 97 Zinc7 15 10 5 08 15 0 25 98 1 Milligrams per liter which is equivalent to parts per million PPM 2 Tested by NSF International ac...

Page 29: ...ne minute any trivalent arsenic will be converted to pentavalent arsenic and reduced by this RO Other water treat ment chemicals such as ozone and potassium permanganate will also change trivalent ars...

Reviews: