background image

3

SECTION I.   INTRODUCTION 

  Your new Reverse Osmosis (R.O.) Drinking Water 

System uses a combination of filtration technologies 

to reduce unwanted contaminants in a water supply. 

The following steps combine to give you the best in 

clear sparkling drinking water: 
 

MECHANICAL FILTRATION/ACTIVATED 

CARBON

–The Sediment/Carbon Module has 

been designed to reduce the larger particles 

such as silt, rust and scale. Its 5 micron 

(equal to 0.0002 inch) nominal rating helps 

to give maximum life to the R.O. Membrane. 

The activated carbon in the Prefilter has been 

designed to reduce any chlorine that may be 

present in the feed water. This pretreatment is 

also necessary for membrane protection.

 

REVERSE OSMOSIS MEMBRANE

–The R.O. 

Membrane is the heart of the filtration system. 

It is designed to reduce the dissolved mineral 

content of the water. Minerals picked up in the 

environment by the water are measured as Total 

Dissolved Solids (TDS). In the Reverse Osmosis 

process, dissolved minerals are separated from 

the incoming water (Feed Water) to produce 

the product water (the Permeate). The excess 

minerals are rinsed to drain (the Reject Water). 

  The membrane is a specially constructed, fully 

aromatic polyamide film, and is classified as a 

Thin Film Composite (T.F.C.).

  The spiral wound construction of the R.O. 

Membrane provides maximum surface area 

for water production and is less susceptible 

to fouling by particulate matter, turbidity and 

colloidal materials. 

 

ACTIVATED CARBON

–The Activated Carbon 

Module contains carbon particles with a vast 

network of pores. The tremendous surface 

area of these pores (typically 800–1200 square 

meters per gram of carbon) gives the carbon 

very good adsorptive sites for substances that 

contribute to tastes and odors. 

 

IN–LINE ACTIVATED CARBON POST FILTER

The In–Line Activated Carbon Post Filter is 

located after the Holding Tank and has been 

designed to reduce the tastes and odors that 

may pass through the system. It adds a final 

polish to the water. 

 

AUTOMATIC SHUTOFF VALVE

–The ASO 

Valve senses when the Holding Tank is full and 

closes the feed water supply to prevent excess 

reject water from going to drain when the unit is 

not producing water.

 

WATER QUALITY MONITOR

–The optional 

Water Quality Monitor has been integrated 

into the faucet base for instant monitoring at 

the touch of a button. The monitor compares 

the level of the Total Dissolved Solids in the 

incoming (feed) water versus the product water 

and calculates the percent rejection. The monitor 

is preset to indicate a level of 75% rejection. 

  A green light indicates that the percent rejection 

is at or above the set (desired) value and that 

the system is producing quality water. 

  An amber light indicates that the product water 

quality is less than acceptable. Because the 

Water Quality Monitor was designed to operate 

best while the system is making water, a false 

reading may occur if tested when your R.O. 

drinking water system is not making water. 

Please empty the Holding Tank, wait 15 minutes 

for the system to begin making water, and test 

your water quality again. If the Water Quality 

Monitor light is still amber, please contact a 

water treatment professional for service. The 

Water Quality Monitor requires a 9 volt battery, 

which is included. Systems not equipped with a 

Water Quality Monitor contain a Water Quality 

Test Kit.

IMPORTANT NOTICES:

This reverse osmosis system contains replaceable treatment components critical for effective performance. It is the user's 

responsibility to, and the manufacturer strongly recommends that the user, periodically test the product water to verify the 

system is performing satisfactorily. See the test kit(s) for sampling instructions.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite 

in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 

280 kPa (40 psig) or greater.
This system conforms to NSF/ANSI 58 for pentavalent arsenic reduction. See the Performance Data Sheet and Arsenic 

Facts section for an explanation of reduction performance.

DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNkNOWN QUALITY, WITHOUT 

ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.

 

Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. 

Summary of Contents for RO35

Page 1: ...NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet R O Drinking Water System Model No RO35 INSTALLATION OPERATION SERVICE MANUAL 1900 Prospect Court Appleton...

Page 2: ...rtains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital...

Page 3: ...supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The optional Water Quality Monitor has been integrated into the faucet base for ins...

Page 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Page 5: ...he manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL RO 35 UNDER SINK INSTALLATION DIAGRAM The Water Qualit...

Page 6: ...housing sediment CARBON MODULE BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see example...

Page 7: ...n area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the moun...

Page 8: ...ink Center punch the hole to provide a starting point for the drill Start with a smaller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch C...

Page 9: ...K 3 8 POLYTUBE TO DRAIN CLAMP BLACK 1 4 POLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fi...

Page 10: ...When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply line The supply line shoul...

Page 11: ...filter changes Mark the two locations the bracket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRIC...

Page 12: ...rds the manifold Take the remaining housing and insert housing O ring into its groove Engage and firmly tighten housing hand tight only Remove the plug labeled ACTIVATED CARBON from the underside of t...

Page 13: ...rval for changing the modules not the R O Membrane is every 6 to 12 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Memb...

Page 14: ...tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following...

Page 15: ...15...

Page 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Page 17: ...mbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing...

Page 18: ...18 MADE IN USA Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit 22 Water Quality Test Kit for systems without the Water Quality Monitor...

Page 19: ...ing 14 S3010 Housing 15 R7078 Optional Water Quality Monitor w Probes and Cover 16 S2116 5 Drain Restrictor 50 GPD 189 lpd 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wr...

Page 20: ...ges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addi...

Reviews: