Wiring
To connect the siren unit to the alarm panel, follow the wiring diagram below:
1. AUX output from the alarm panel connects to DC-12V port on the siren unit
2. SIREN output from the alarm panel connects to SN port on the siren unit
3. Connect 12vdc back up battery of the siren unit to the siren battery port
4. WGAP864 alarm panel only:
Install a 3K3 resistor connecting across the SIREN port,
then another 3K3 resistor connecting in-series with the PANIC port on the WGAP864