Page 1: ...WatchGuard AP332CR Hardware Guide WatchGuard AP332CR Outdoor Access Point ...

Page 2: ...WatchGuard Technologies Inc 2 ...

Page 3: ...ty providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission is to make enterprise grade security accessible to companies of all types and sizes through simplicity making WatchGuard an ideal solution for Distributed Enterprises and SMBs WatchGuard is headquarte...

Page 4: ...cess Point 15 Wall Mount Installation 16 Pole Mount Installation 17 Antenna Installation 18 Connect the Ground Wire 18 Connect the Access Point 19 How to Assemble the Weatherproof Connector 20 How to Disassemble the Weatherproof Connector 21 Ethernet Power Injector Optional 22 Notices 24 Safety Warning 24 FCC Certification 24 CE Notice 25 Industry Canada Certification 25 EU Declaration of Conformi...

Page 5: ...29 Mexico NOM 29 Japan Statement 29 Japan VCCI Class B Statement 29 Taiwan NCC Statement 29 RoHS Statement 30 WEEE Statement 30 REACH Certificate of Compliance 30 Declaration of Conformity 32 WatchGuard Technologies Inc 5 ...

Page 6: ...or deployment conditions and built with an industrial rated IP67 enclosure The AP332CR features 802 11ax 2x2 2 4 GHz and 5 GHz dual concurrent radios that support data rates up to 1148 Mbps on the 2 4 GHz band and 2402 Mbps on the 5 GHz band Power is provided by a PoE Power over Ethernet power source WatchGuard Technologies Inc 6 ...

Page 7: ... Memory n NOR Flash 8MB n NAND Flash 256MB n RAM DDR3L 512MB x 2 Radios n Radio 1 2 4 GHz 2x2 802 11b g n ax n Radio 2 5 GHz 2x2 802 11a n ac ax Antennas n 2 x 2 4 GHz 5 dBi n 2 x 5 GHz 5 dBi 4 x omnidirectional antennas are included Note The device must have antennas connected for full range and functionality Ethernet Interfaces 1 x 2 5 GbE Ethernet port Power Interface PoE 802 3at 48 57V DC Powe...

Page 8: ...ce has adequate clearance for air flow and cooling This equipment is not suitable for use in locations where children are likely to be present Other environmental requirements Operating Temperature 20 C to 60 C 4 F to 140 F Operating Humidity 5 to 95 non condensing Non operating Temperature 40 C to 80 C 40 F to 176 F Non operating Humidity 5 to 95 non condensing WatchGuard Technologies Inc 8 ...

Page 9: ...s the access point to a wired LAN connection through a switch or hub This port also provides PoE 802 3at power for the access point 5GHz Antenna connector for the 5 GHz radio Top Panel 5GHz Antenna connector for the 5 GHz radio 2 4GHz Antenna connector for the 2 4 GHz radio WatchGuard AP332CR Hardware Guide 9 WatchGuard Technologies Inc ...

Page 10: ...ints that run firmware 1 1 7 0 and higher have LED indicators that can show different status conditions while booting activation validation feature key download WatchGuard Cloud device registration and the connection to WatchGuard Cloud The access point briefly passes through each stage until the device is connected to WatchGuard Cloud and shows a solid blue LED indicator If the access point remai...

Page 11: ...se for Wi Fi in WatchGuard Cloud n Make sure the access point is connected to the network and has received an IP address from DHCP n Make sure the access point can connect to watchguard io for product activation and feature key updates n If you set up an access point behind a firewall that performs inspection on HTTPS traffic you must add watchguard io to the content inspection exception bypass li...

Page 12: ...e for the access point n Check the access point allocation status to see whether the device was deallocated from the subscriber account Solid Blue Successfully connected to WatchGuard Cloud Device is online and connected to WatchGuard Cloud Flashing Blue Flash LED action from WatchGuard Cloud LED flashes blue for 60 seconds for identification Access Point Firmware 1 1 4 0 and Lower Wi Fi in WatchG...

Page 13: ...r account For more information see Add an Access Point to WatchGuard Cloud n If you have configured DHCP make sure your access point has received an IP address from DHCP and can connect to the network n Access points use TCP port 443 to connect to WatchGuard Cloud Access points must also be able to connect to these destinations o watchguard io for product activation and feature key updates o watch...

Page 14: ...twork issue or blocked port Use the access point command line interface CLI to run network connectivity diagnostic tests For more information see Access Point Command Line Interface Solid Blue Successfully connected to WatchGuard Cloud Device is online and connected to WatchGuard Cloud Flashing Blue Flash LED action from WatchGuard Cloud LED flashes blue for 60 seconds for identification Current f...

Page 15: ...es these accessories The MAC address and serial number of your access point are printed on a label on the back of the device Make sure you record this information before you mount the device WatchGuard AP332CR Hardware Guide 15 WatchGuard Technologies Inc ...

Page 16: ...r mounting holes of the wall mounting bracket n Use an appropriate drill bit to drill holes that are 8 1mm diameter and 26mm depth in the markings and hammer the bolts into the openings n Screw the anchors into the holes until they are flush with the wall 2 Screw the included screws into the anchors 3 Slide the mount bracket into the slot of the access point WatchGuard Technologies Inc 16 ...

Page 17: ... 1 Insert the pole mount clamps in the tabs on the mounting bracket and wrap the clamps around the pole 2 Attach the access point to the mounting bracket and tighten the straps to make sure the access point is firmly attached to the pole WatchGuard AP332CR Hardware Guide 17 WatchGuard Technologies Inc ...

Page 18: ...n use other third party omnidirectional and directional antennas based on your deployment requirements If you use other third party antenna types you are responsible for verifying compliance with regional based regulations based on the peak gain values Connect the Ground Wire To make sure your access point is safely protected from electrical events we recommend you ground the access point accordin...

Page 19: ...etwork into the LAN PoE port on the bottom panel of the access point Make sure the other end of the Ethernet cable is connected to your network through a hub switch or injector with PoE 802 3at power enabled WatchGuard AP332CR Hardware Guide 19 WatchGuard Technologies Inc ...

Page 20: ...ard AP332CR Hardware Guide How to Assemble the Weatherproof Connector Use these instructions to connect the Ethernet cable to the access point through the weatherproof connector WatchGuard Technologies Inc 20 ...

Page 21: ...How to Disassemble the Weatherproof Connector Use these instructions to disconnect the Ethernet cable from the weatherproof connector WatchGuard AP332CR Hardware Guide 21 WatchGuard Technologies Inc ...

Page 22: ... Ethernet Power Injector into an AC power source 2 Connect an Ethernet cable from your network backbone for example a PoE capable router switch or hub to the LAN connector on the Ethernet Power Injector 3 Connect an Ethernet cable from the LAN PoE Ethernet interface on the access point to the PoE connector on the Ethernet Power Injector The table provides the specifications for the power adapter E...

Page 23: ... 10 100 1000 2500 Mbps data and power Voltage Pin4 5 54V Pin7 8 Return Indicator Power Green Temperature Operating 0 40 C 32 104 F Storage 30 80 C 22 176 F Humidity 5 90 Operating and storage Dimensions L 99 mm 3 9 W 68 5 mm 2 27 H 33 mm 1 3 Weight 149 6 g 0 33 lbs WatchGuard AP332CR Hardware Guide 23 WatchGuard Technologies Inc ...

Page 24: ...ly with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However...

Page 25: ...tionnement indésirable Caution For devices with detachable antenna s the maximum antenna gain permitted for devices in the bands 5250 5350 MHz and 5470 5725 MHz must be such that the equipment still complies with the e i r p limit For devices with detachable antenna s the maximum antenna gain permitted for devices in the band 5725 5850 MHz must be such that the equipment still complies with the e ...

Page 26: ...re Statement This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 42cm between the radiator your body Déclaration d exposition aux radiations Cet équipement est conforme aux limites d exposition aux rayonnements ISED établies pour un environnement non contrôlé Cet équipement doit ...

Page 27: ...lds 0 Hz 300 GHz EN 301 489 1 V2 2 3 Electromagnetic compatibility and Radio spectrum Matters ERM Electro Magnetic Compatibility EMC standard for radio equipment and services Part 1 Common technical requirements EN 301 489 17 V3 1 1 Electromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment Part 17 Specific conditions for Broadband D...

Page 28: ...N covering the essential requirements of article 3 2 of the RED Directive EN 301 893 V2 1 1 Broadband Radio Access Networks BRAN 5 GHz high performance RLAN Harmonized EN covering the essential requirements of article 3 2 of the RED Directive EN 50385 2017 This product standard is related to human exposure to radio frequency electromagnetic fields transmitted by base station equipment in the frequ...

Page 29: ...rferencia perjudicial y 2 este equipo o dispositivo debe aceptar cualquier interferencia incluyendo la que pueda causar su operación no deseada Japan Statement こ の装置には 電波法に基づく 技術規則適合証明書の認定を受けた特定の無線装置が含まれています This equipment contains specified radio equipment that has been certified to the Technical Regulation Conformity Certification under Radio Law Japan VCCI Class B Statement こ の装置は ク ラ スB 情報技術装置...

Page 30: ...to be disposed of please contact WatchGuard Customer Care Department at U S Customers 877 232 3531 International Customers 1 206 613 0456 WatchGuard is reasonably confident that our products do not contain any substances or hazardous materials presently banned by any legislation and do not present a risk due to hazardous materials WEEE recovery professionals should also note that these products do...

Page 31: ...he following reasons n WatchGuard does not import more than 1 metric ton per year of a substance as defined by REACH n WatchGuard products are non chemical products that are not designed to release any substance under normal and reasonably predictable application n Our products do not contain the listed substances at more than 0 1 by weight of the whole product part WatchGuard AP332CR Hardware Gui...

Page 32: ...WatchGuard AP332CR Hardware Guide Declaration of Conformity WatchGuard Technologies Inc 32 ...