USB Port

The USB port is currently not in use.

Reset Button

Resets the WatchGuard AP to factory-default settings. You must use a paper clip or other small
object to press the reset button through the hole.

To reset the device to factory-default settings, while the AP is powered on, press and hold the reset
button for up to 10 seconds until all LEDs go off to indicate that the AP has rebooted.

If you press the reset button while the AP is not powered on or is booting, the reset
button will have no effect.

WatchGuard AP325 Hardware Guide

4

WatchGuard Technologies, Inc.

Summary of Contents for AP325

Page 1: ...WatchGuard AP325 Hardware Guide AP325 Access Point ...

Page 2: ...ty providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission is to make enterprise grade security accessible to companies of all types and sizes through simplicity making WatchGuard an ideal solution for Distributed Enterprises and SMBs WatchGuard is headquarte...

Page 3: ...at Surface Bracket Optional 9 Connect the AP 11 Connect the AP for Link Aggregation 11 Ethernet Power Injector Optional 12 Power Adapter 13 Notices 14 Safety Notices 14 Product Safety Certification 14 Safety Warning 14 Disclaimer 14 HINWEISE ZUR SICHERHEIT 14 Sicherheitshinweis 15 AVISO DE SEGURIDAD 15 Certificación de seguridad del producto 15 Advertencia de seguridad 15 FCC Certification 16 CE N...

Page 4: ...tion of Conformity Wireless 18 Brasil ANATEL 21 Mexico NOM 21 Taiwan Class B Notices 21 Taiwan NCC 21 Taiwan RoHS 22 Japan VCCI Notice Class B ITE 22 RoHS Statement 23 WEEE Statement 23 REACH Certificate of Compliance 23 WatchGuard Technologies Inc iii ...

Page 5: ...ration security and monitoring Basic Wi Fi with WatchGuard Firebox Gateway Wireless Controller Local management configuration security and monitoring of APs directly from your WatchGuard Firebox The WatchGuard Firebox requires Fireware v12 1 and higher The third radio is not available when you manage the AP325 locally with a Gateway Wireless Controller About Your Hardware Hardware Specifications T...

Page 6: ...TBF Rating 1 081 559 hours at 25 C 535 205 hours at 45 C Dimensions L 196 mm 7 72 W 196 mm 7 72 H 43 mm 1 69 Weight 850g 1 87lb Environmental Requirements To safely install your WatchGuard AP we recommend that you n Install the device indoors n Make sure the device has adequate clearance for air flow and cooling n Connect it to a surge protected power supply to prevent damage from sudden power cha...

Page 7: ...o LAN interfaces This enables you to extend the wired network on the second LAN interface For more information see the Fireware Help Power Input You can power the WatchGuard AP325 by 802 3at PoE or 802 3af PoE on the LAN1 PoE interface or an optional power adapter In 8 8 2 and higher the AP can use 802 3af PoE with no loss in functionality In 8 8 1 and lower the use of 802 3af PoE results in limit...

Page 8: ...tton through the hole To reset the device to factory default settings while the AP is powered on press and hold the reset button for up to 10 seconds until all LEDs go off to indicate that the AP has rebooted If you press the reset button while the AP is not powered on or is booting the reset button will have no effect WatchGuard AP325 Hardware Guide 4 WatchGuard Technologies Inc ...

Page 9: ...WatchGuard AP325 Hardware Guide Device Indicators The LED device indicators show the status of the AP WatchGuard Technologies Inc 5 ...

Page 10: ...from the DHCP server LAN1 PoE Off No Ethernet link Solid Green Network interface is up and connected at 10 100 1000 Mbps LAN2 Off No Ethernet link Solid Green Wi Fi Cloud mode 8 8 2 and higher For APs with additional LAN ports interface will be green if the interface is up and a wired extension or link aggregation is enabled on the interface in Wi Fi Cloud 8 8 1 Network interface is up and connect...

Page 11: ...Mbps Fast Flash Green Did not receive valid IP address from DHCP Slow Flash Green Cannot connect to WatchGuard Wi Fi Cloud Intermittent Flash Green Activity on LAN1 port Off No Ethernet link LAN2 Solid Green Device connected to LAN2 port at 10 100 1000 Mbps Flashing Green Activity on LAN2 port Off No Ethernet link 2 4 GHz Solid Green Client connected to 2 4 GHz radio Intermittent Flash Green Activ...

Page 12: ...5mm Part WG8021 To install the AP325 on a ceiling with a T rail 1 Put the first mounting post on the back of the AP over the lower bracket notch and rotate into place 2 Make sure that all the mounting posts on the back of the AP are securely positioned in their bracket notches 3 To attach the bracket to the T rail rotate the bracket so it is parallel to the T rail and snap the bracket on the T rai...

Page 13: ...art WG8038 1 Attach the bracket to the mounting surface with screws not included 2 Pull the release key outward to unlock the mount bracket then attach the AP stubs to the bracket holders You may need to adjust the stubs for a firm fit 3 Push in the release key to lock the hooks Make sure all hooks are locked in place WatchGuard Technologies Inc 9 ...

Page 14: ...4 Fasten the included screw to the release key to lock the AP to the bracket WatchGuard AP325 Hardware Guide 10 WatchGuard Technologies Inc ...

Page 15: ...eptacle on the back of the AP325 4 Plug the power adapter into an 100V 240V 50 60 Hz AC power source Connect the AP for Link Aggregation With WatchGuard Wi Fi Cloud you can use both Ethernet ports of the AP325 for link aggregation that enables these ports to logically merge into a single link for higher aggregate bandwidth You must enable link aggregation in a device template for the AP325 and lin...

Page 16: ... Injector into an AC power source 2 Connect an Ethernet cable from your network backbone for example a router switch or hub to the LAN connector on the Ethernet Power Injector 3 Connect an Ethernet cable from the LAN1 PoE Ethernet interface on the AP to the PoE connector on the Ethernet Power Injector The table below provides the specifications for the Ethernet PoE injector Ethernet Power Injector...

Page 17: ...idity 5 90 Operating and storage Dimensions L 99 mm 3 9 W 68 5 mm 2 27 H 33 mm 1 3 Weight 149 6 g 0 33 lbs Power Adapter An optional AC power adapter supplies 12V DC power to the WatchGuard AP325 and includes region specific adapter plugs AC Power Adapter Specs WatchGuard Part Number WG8039 AC Input Voltage Rating 100 240V 50 60Hz 0 5A max Output Voltage DC 12V 1 5A Region Specific Adapter Plugs U...

Page 18: ...13 Safety Warning n Do not place objects on the power cord n Do not obstruct the ventilation openings These openings prevent overheating of the machine n Never push objects of any kind into slots or openings on this equipment Making a contact with a voltage point or shorting out a part may result in fire or electrical shock n When removing or installing an appliance follow the general installation...

Page 19: ...a atentamente las siguientes instrucciones antes de utilizar el producto y se refieren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto Información adicional se puede encontrar en la Guía del usuario electrónica Certificación de seguridad del producto El producto tiene certificación de seguridad WatchGuard bajo las siguientes normas n IEC 60950 1 2005 S...

Page 20: ...he user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter For operation within 5 15 5 25GHz 5 47 5 725GHz frequency range it is restricted to indoor environment The band from 5600 5650MHz will be disabled by the software during the manufacturing and cannot be changed by the end user This device meets all ...

Page 21: ... un fonctionnement indésirable Caution i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems ii the maximum antenna gain permitted for devices in the bands 5250 5350 MHz and 5470 5725 MHz shall be such that the equipment still complies with the e i r p limit iii the maximum antenna gain pe...

Page 22: ...MHz Sélection dynamique de fréquences DFS pour les dispositifs fonctionnant dans les bandes 5250 5350 MHz 5470 5600 MHz et 5650 5725 MHz For indoor use only Pour une utilisation en intérieur uniquement Radiation Exposure Statement This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distan...

Page 23: ...dio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment Part 17 Specific conditions for Broadband Data Transmission Systems This device is a 5GHz wideband transmission system transceiver intended for use in all EU member states and EFTA countries except in France and Italy where restrictive use applies In Italy the end user should apply for a license at the national...

Page 24: ...WatchGuard AP325 Hardware Guide 20 WatchGuard Technologies Inc ...

Page 25: ...vidamente autorizados Mexico NOM La operación de este equipo está sujeta a las siguientes dos condiciones 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo o dispositivo debe aceptar cualquier interferencia incluyendo la que pueda causar su operación no deseada Taiwan Class B Notices Taiwan NCC WatchGuard Technologies Inc 21 ...

Page 26: ...Taiwan RoHS Japan VCCI Notice Class B ITE WatchGuard AP325 Hardware Guide 22 WatchGuard Technologies Inc ...

Page 27: ...is reasonably confident that our products do not contain any substances or hazardous materials presently banned by any legislation and do not present a risk due to hazardous materials WEEE recovery professionals should also note that these products do not have any materials that are of particular high value in their individual form REACH Certificate of Compliance The new EU chemicals policy REACH ...

Page 28: ...uard products are non chemical products that are not designed to release any substance under normal and reasonably predictable application n Our products do not contain the listed substances at more than 0 1 by weight of the whole product part WatchGuard AP325 Hardware Guide 24 WatchGuard Technologies Inc ...