Wassermann WW-33 User Manual Download Page 8

 8  Operation

 8.1 

General Operating Instructions

All instructions for using the unit, whether in verbal or written form, are based on our own 

experience and experimentation and can only be regarded as guidelines. 

1. Prepare cap as per Point 7.

2. Turn the pressure valve (black knob on housing) to CLOSED.

3. Now increase pressure with the lever, staying within the permissible zone on the 

pressure gauge (green zone).

4. If necessary, increase the pressure to the maximum, always staying within the 

permissible zone on the pressure gauge (green zone).

5. Once the pressure remains steady, it can be released (valve opened).

6. Raise the piston and remove the cap.

The gauge will not be accurate while the pressure is being distributed through

the plastic. 

Full pressure

 can only be achieved by 

pumping on the lever 

several

 times with appropriate pauses in between. Once the cap is fully 

enclosed, the pressure remains steady.

The return spring on the piston takes it back 

automatically

 to its zero position.

It has a stroke of about 12 mm. As soon as it reaches this level, it is limited 

automatically

. No more pressure is possible.

The oil level should be monitored on the gauge when the piston is down. If 

necessary, add hydraulic oil. A black vent screw is provided for this purpose. 

To remove (oil filler nozzle). This is located behind the left-hand support at the

top of the housing. No damage can result from overfilling as the surplus oil 

merely flows out into the nozzle.

Note: Use only SHELL TELLUS 32 hydraulic oil.

8

Summary of Contents for WW-33

Page 1: ...Hydraulic Press WW 33 2 4 flasks 1 3 flasks Fig USER MANUAL...

Page 2: ...neral safety guidelines and the applying laws to prevent accidents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faul...

Page 3: ...3 Storage 7 7 Installation Start up 7 8 Operation 8 8 1 General Operating Instructions 8 9 Troubleshooting 9 9 1 Guidelines for Venting 9 10 Care and Maintenance 10 10 1 Cleaning 10 10 2 Maintenance...

Page 4: ...and sturdy plastic coated housing all contribute to the unit s long service life As the distance between supports is 152 mm the press is also suitable for larger caps IVOCAP and stirrup pieces SPECIA...

Page 5: ...ws your attention to specific features that has to be observed 3 Safety Guidelines Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user m...

Page 6: ...ese instructions Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions 5 Application With a con...

Page 7: ...om temperature 6 3 Storage If the unit is to be stored for an extended period protect it from moisture and dust 7 Installation Start up Please remove the safety packing as follows Take the pump lever...

Page 8: ...gauge will not be accurate while the pressure is being distributed through the plastic Full pressure can only be achieved by pumping on the lever several times with appropriate pauses in between Once...

Page 9: ...ed oil recommended oil 9 1 Guidelines for Venting 1 Turn press on right side and pump 2 Nothing then remove piston as described below and fill with oil up to top edge of cylinder Undo set screw in U p...

Page 10: ...nly normal cleaning sponge damp cloth mild detergent and no further chemical additives The piston track should be cleaned daily with a clean linen cloth and then lightly lubricated with the recommende...

Page 11: ...asks 129995 Universal flask clamp for 2 flasks 129996 Universal flask clamp for 1 flask 129997 Hydraulic oil 500 ccm 629005 10 7 Warranty The warranty period for our equipment is 12 months If faults o...

Page 12: ...W x D D with pump lever 200 x 158 295 mm Height max 710 min 540 mm max 650 min 480 mm Distance between columns 152 mm Distance plunger plate max 272 min 102 mm max 212 min 42 mm Weight 16 0 kg 14 7 k...

Page 13: ...ies with the described EU guidelines This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur d Union europ enne Cet avis est n...

Page 14: ...Notes 14...

Page 15: ...15...

Page 16: ......

Reviews: