The
WP-Ex 10 II
is powered by switching on the main switch [1].
The main / protection switch[1] prevent a unwanted „start-up“ for example after a power
outage.
The suction can be turned on or off manually with a toggle switch [3].
With the gag switch [4] two speed settings can be choosen.
9 Troubleshooting
Fault
Cause
Solution
Spindle does not
hold
Spindle loose
Set the spindle in place by lightly tapping with
a hammer
Spindle cannot be
loosened
Spindle is too firmly
attached to the cone
Contact our service department
No or very little
suction capacity
Filter bag full
Replace filter bag
Ball bearing noise
Ball bearing
defective
Contact our service department
Light does not work LEDs defective
Replace the LEDs
Device does not
work
Fuse defective
Check the fuse.
Disconnect the power plug before starting
any maintenance work.
Change the fuse if necessary:
REF 582013 FUSE 6.3 A M
If the above recommendations do not solve the problem, contact your dental depot
or our service department.