6. Use the numeric keypad to enter the program number. If you enter
0
or a number
greater then
30
,
Err-P
then
Pr nr
appear on the display.
7. Press
ENTER.
Dosing starts and the
READY
light goes out.
The program checks that the quantities do not exceed the maximum value. If the
maximum value is exceeded,
Err-H
appears on the display and dosing is stopped.
8. The program also checks that the amount of powder is greater than
5g
. If it is less,
Err-
L
appears on the display and dosing does not start. Another check is carried out to
make sure the maximum dosing portion does not exceed
1000
% of the powder amount
(
Err-H
message) and that the minimum dosing portion is greater than
2g
(if not,
message
Err-L
).
9. To interrupt the process, you press
CLR,
then
ENTER
to continue.
10. If no errors are detected, the symbol
appears on the display to indicate which pump
is working.
11. The pump (or pumps) automatically dose(s) the predetermined quantity of liquid.
12. When the next pump is switched on, the display shows the
symbol of the pump
which is working. When dosing finishes, the
END
light come on.
13. After
ENTER
is pressed, the dosing scales are ready to start again. The
READY
light
comes on and
END
goes out (only to program level C2_08).
8.5.1
Stopping the Dosing Process
•
The dosing process can be stopped immediately by pressing
CLR. Clr
appears on
the display. You press
ENTER
to reset the unit. The
READY
light comes on.
Dosing can be stopped at anytime by pressing CLR.