 3.1 

Duty S6 (4 min / 10 min)

The duty of 

S6 (4 min / 10 min) 

recommends a loading period of 4 minutes and a pause of

6 minutes in order to prevent an overheating of the motor handpiece. 

 4  Responsibility for Operation or Damage

The responsibility for operating the device lies exclusively with the owner or user if said 

device is incorrectly serviced, maintained or altered by persons not employed by an 

authorised dealer or if the device is used in a manner contrary to its specified purpose.

The unit has to be maintained and operated in accordance with this user manual. 

Wassermann Dental-Maschinen GmbH is not responsible for damage arising from the 

nonobservance

 of these instructions.

Warranty and responsibility provisions contained in the sales and supply conditions of 

Wassermann Dental-Maschinen GmbH are not extended by these instructions.

 4.1 

Warranty 

The warranty period for our equipment is 12 months. If faults occur within the 

warranty period, contact your dental depot or get in touch directly with our service 

department.

Your equipment should only be operated in perfect condition. If faults occur which 

could harm operators or third parties, the unit should not be used until it has been 

fixed.

This warranty does not cover damage caused by improper use, external mechanical

causes, transport damage or interference with the unit by unauthorized persons.

6

Summary of Contents for 149996

Page 1: ...Suction Unit Timobil Mobil Suction Table with Motor Handpiece USER MANUAL ...

Page 2: ...dents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this user manual Keep this user manual in a safe place where it can be referred to as required at any time The unit complies with the relevant EU guidelines The unit is ...

Page 3: ...on Start up 8 8 Operation 9 8 1 General Operating Instructions 9 9 Troubleshooting 9 10 Care and Maintenance 10 10 1 Repairs 10 10 2 Changing the Filter 10 10 3 Spare Parts 10 10 4 Service Hotline 0049 0 40 730 926 20 24 10 10 5 Cleaning 11 10 6 Cleaning and or Servicing the Chuck 11 10 7 Scope of Delivery Accessories 12 11 Technical Data 12 12 Disposing of the Unit 13 12 1 Information on Disposal...

Page 4: ...and closes the chuck The unit has overload protection Works with the low pressure principle No heat eduction no cooling of hands high suction volume virtually noiseless operation runs quietly suitable for continuous operation With robust and ergonomic equipment engine Strong torque high rotation accuracy and brushless motor Suction unit can be started automatically by the motor handpiece High prot...

Page 5: ... equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application WARNING Servicing and repairs should be carried out only by authorised specialists Disconnect the power plug before starting any maintenance work Make sure that the equipment is connected to the correct power source WARNING Risk of injury You shou...

Page 6: ...tal Maschinen GmbH is not responsible for damage arising from the nonobservance of these instructions Warranty and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions 4 1 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get...

Page 7: ...rom the power socket Make sure that it is packed correctly in order to avoid accidental damage Be sure to check for any transport damage when unpacking the goods Note down any damage if found 6 2 Storage The unit location is very important when it comes to workplace safety even if it is only to be set up there for a short period The room should be dry well ventilated and vibration free An even tem...

Page 8: ...ipation Do not install the unit outdoors or in places without proper ventilation Before start up be sure the device reaches room temperature 7 Installation Start up 1 Pull the cable out slowly it will stop at the desired length 2 Pull the cable out quickly it will roll back fully onto the drum 3 Finally insert the power plug into the socket making sure that the mains and the unit operate on the sa...

Page 9: ...Solution Little or no extraction Filter bag full Change filter bag No power Microswitch wrongly adjusted Reset microswitch Contact our Service Department Motor switches off Overload protection Allow unit to cool Motor does not run Chuck mechanism open Close chuck mechanism Little or no extraction Filter bag full Change filter bag If the above recommendations do not solve the problem contact your d...

Page 10: ... Filter The unit has a one way filter bag which is easy to change when it is full Undo the locks on the right and left and remove the cover You can now replace the full bag with a new one Change the filter regularly to guarantee trouble free dust extraction It is time to change the bag if the extraction power becomes noticeably weaker and or if dust collects in the extractor area 10 3 Spare Parts ...

Page 11: ... 6 Cleaning and or Servicing the Chuck WARNING Risk of injury You should change the tool or the chuck only after the motorised handpiece has come to a complete stop Do not touch the rotating tool 1 Open the chuck 2 Unscrew the plastic tip by turning it manually to the left 3 Insert the chuck key fully into the chuck 4 Hold the shaft firmly with an adjustable wrench 5 Undo the chuck by turning the ...

Page 12: ...filterbag for plaster class 1 class 2 1 set 4 pieces 611018 Storage tray 149010 11 Technical Data Timobil Artikel Nr 149999 Voltage 220 240 V 50 60 Hz Power consumption 1 5 A Plug socket power consumption max 8 A Output 350 W W x H x D 530 x 900 x 480 mm Weight 28 1 kg Suction capacity 500 m3 h free blowing Control unit output 160 W Handpiece motor output 95 W Handpiece motor speed 1000 40 000 min...

Page 13: ...otect the environment prevent environmental pollution and improve the recycling of raw materials the European Commission adopted a directive that requires the manufacturer to accept the return of electrical and electronic units for proper disposal or recycling Within the European Union units with this symbol should not therefore be disposed of in unsorted domestic waste For more information regard...

Page 14: ...mmung verändert wird This is to confirm that the above mentioned machine complies with the described EU guidelines This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur d Union européenne Cet avis est nul et non avenant si cette machine est modifiée sans notre accord Esta máquina anteriormente mencionada cumple con los lim...

Page 15: ...Notes 15 ...

Page 16: ......

Reviews: