10
40°nozzle - White.
This nozzle delivers a 40 degree spray pattern and a less powerful stream of water. It covers a wide
area of cleaning; this nozzle should be used for most general cleaning jobs.
Chemical Nozzle – black.
This nozzle is used to apply chemicals or cleaning solutions. It has the least power stream.
Maintenance
Warning:
When performing maintenance, you may be exposed to hot surfaces, water pressure, or moving parts that
can cause serious injury or death!
Before performing any maintenance or repair, stop engine and let it cool and release all water pressure. The engine
contains flammable fuel. Do not smoke or work near open flames while performing maintenance.
Nozzle cleaning:
If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop.
If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately
using the nozzle kit supplied.
Wand/Lance:
1.
Shut off the pressure washer and turn off the water supply.
2.
Disconnect the wand/lance from the gun.
3.
Clean the nozzle using the nozzle cleaner provided or a straightened paper clip. Insert into the nozzle end and
work back and forth until obstruction is removed.
4.
Direct water supply into nozzle end to back flush loosened particles for 30 seconds.
5.
Reconnect wand/lance to gun and turn on water supply.
6.
Start pressure washer.
Water Inlet Screen Cleaning:
All pumps are equipped with some type of water filter screen. This screen should be checked periodically and cleaned
if necessary.
1.
Remove the filter screen and flush with clean water.
2.
Place the cleaned filter screen into the water inlet connector.
Storage
Optimum Winterizing Procedure
1.
Drain all water from high pressure washer hose
. Roll hose carefully and do not allow hose to be kinked.
2.
Drain all water from gun and lance
by holding gun in a vertical position with nozzle end pointing down and
squeezing trigger. Store in gun/hose holder.
3.
Store chemical hose.
High pressure water hose, so they are protected from damage, such as being run over.
It is recommended that you follow these steps to protect the internal seals of the washer pump when storing the unit for
more than 30 days and/or when freezing temperature is expected;
4.
Obtain a funnel,
200ml of antifreeze, and approximately 1 meter of garden hose with a male connector attached to
the one end
5.
Disconnect spark plug wire
6.
Connect the hose
to water inlet of pump
7.
Add antifreeze to
hose.
8.
Pull engine starter rope slowly several times.
Until antifreeze comes out of high pressure water hose connection
of pump
9.
Remove short hose
from water inlet of pump