8 GM - Operator Manual 141218
User Settings
Default
Selection
Power Save
ON
ON/OFF
Detergent Injection Time
12
5 - 30 secs
Display Contrast
27
10 - 40
User Programming
The
User Settings
menu is accessed for programming by pressing the UP and DOWN
keys simultaneously for a few seconds. The programming options are specified in the
table below:
Power Save
function reduces the rinse temperature setting by 10°C when the machine is
idle for 5 minutes or more. The temperature settings return to the set value when door is
opened or START/STOP key is pressed.
QuickStart
starts washing regardless of rinse temperature. If rinse temperature is not
sufficient cycle countdown will stop at 22 seconds. Washing continues until rinse reaches
temperature required for sanitization and countdown then resumes.
Troubleshooting
If an error message appears on the control display first try turning the machine OFF for 30
seconds and then back ON.
Display Code
Cause
Remedy
7.
Fill Failure - wash tank
not full after fill timeout
Check drain upstand fitted
Fit upstand before
filling
Check flow rate of water supply
Check water supply
8.
Drain Failure
Drain hose jammed/blocked
Check/unblock drain
hose
Drain upstand not removed
Remove upstand
before draining
Keypad Start Button Colours
Machine State
Colour
Door Open
Purple
Filling
White
Heating
Orange
Ready
Green
Ecopower
Blue
Washing
Red
Error
Flashing Red
If the error message remains call for service