Daily Cleaning
•
Remove Scrap Trays (10) and clean with a brush and water to clear grid.
•
Remove Wash Pump Inlet Filter (12) and clean with a brush and water to clear grid.
•
Return Drain Upstand (11), Wash Pump Inlet Filter (12) and Scrap Trays (10) to the machine.
Weekly Cleaning
•
To be done in conjunction with Daily cleaning.
•
Remove Lower Wash Arms (8)
–
lift up to unhook the arm and then withdraw.
•
Remove Upper Wash Arms (7)
–
push the locking bar up and then withdraw.
•
Check to ensure arms are clear of obstructions. Remove end caps to clear if not.
•
Flush Arms (7 & 8) with water. Use a toothpick or paper clip if necessary to clear jets.
•
Return the Wash Pump Inlet Filter (12), the Drain Plug (11), Scrap Trays (10),
Lower Wash Arms (8) and Upper Wash Arms (7) to the machine.