D R Y E R   I N S T A L L A T I O N   M A N U A L

DOC. NO.  0

96008

EDITION 

28.2019

Operating Manual

CROSSOVER 

SERIES

Summary of Contents for CROSSOVER 2.0 Series

Page 1: ...D R Y E R I N S T A L L A T I O N M A N U A L DOC NO 096008 EDITION 28 2019 Operating Manual CROSSOVER SERIES ...

Page 2: ...cally recommended in the user maintenance instructions or in published user repair instructions that you understand and have the skills to carry out Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint screen b...

Page 3: ...ment Installation and service must be performed by a qualified installer service agency or gas supplier GROUNDING INSTRUCTIONS This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance FIRE HAZARD Failure to follow safety warnings...

Page 4: ...Model Numbers Electric DLHF0 CEMI DLHF0 CE DLHS0 CEMI DLHS0 CE DLHF0817EMI DLHF0817E DLHS0817EMI DLHS0817E Gas DLHF0817GMI DLHF0817G DLHS0817GMI DLHS0817G ...

Page 5: ... GAS ELECTRIC MACHINE SERIAL NUMBER Risk of Fire Clothes dryer installation must be performed by a qualified installer Do not install a clothes dryer with flexible plastic venting materials If flexible metal foil type duct is installed it must be of a specific type identified by the appliance manufacture as suitable for use with clothes dryers Flexible venting materials are known to collapse be ea...

Page 6: ...le operating open the door The machine must stop If the machine fails to stop disconnect power and arrange for service 3 DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO BYPASS OR REWIRE ANY OF THE MACHINE SAFETY DEVICES AS THIS CAN RESULT IN SERIOUS ACCIDENTS 4 Be sure to keep the machine s in proper working order Follow all maintenance and safety procedures 5 Further information regarding machine safet...

Page 7: ... with adequate clearance for air openings in the cabinet The dryer must be installed or stored in an area where it will not be exposed to water and or weather Dryers installed in residential garages must be elevated 18 inches 45 72 cm above the floor IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed in a location environme...

Page 8: ...k Installation 2 2 Fresh Air Supply 2 3 Exhaust Requirements 2 3 Outside Ductwork Protection 2 4 Venting Single Horizontal Vertical and Multiple 2 4 Electrical Requirements 2 6 Gas Information 2 8 Piping 2 8 Fuel Conversion 2 10 Gas Pressure Adjustment 2 11 Gas Pressure Testing 2 11 Preoperational Instructions 3 1 Shutdown Instructions 4 1 Coin Meter Installation and Blocking Plate 5 1 Preventive ...

Page 9: ...RFLOW 192 cf m 326 21 cm h HEAT INPUT 19000 Btu hr 4791 12 kCal hr EXHAUST CONNECTION 4 in 10 16 cm NATURAL GAS SUPPLY 4 5 10 5 in WC NATURAL GAS MANIFOLD 3 0 in WC L P SUPPLY PRESSURE 11 in WC L P MANIFOLD PRESSURE 11 14 in WC INLET PIPE CONNECTION 3 8 M N P T ELECTRIC MACHINE VOLTAGE AVAILABLE 120 240V 1ø 60 Hz 120 208V 3ø 60 Hz APPROXIMATE NET WEIGHT 154 lb 69 85 kg APPROXIMATE SHIPPING WEIGHT ...

Page 10: ...r should consult the local gas supplier for proper instructions to be followed in the event the user smells gas The instructions should be posted in a prominent location For personal safety the dryer must be electrically grounded in accordance with local and or country codes In the absence of these codes use the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the Canadian Elec...

Page 11: ... windows and doors closed Disconnect power before resetting replacing hi limit thermostats Dry only water washed fabrics Do not dry articles spotted or washed in dry cleaning solvents combustible detergents or all purpose cleaner Explosion could result Do not dry rags or articles coated or contaminated with gasoline kerosene oil paint or wax Explosion could result Items that have been spotted or s...

Page 12: ...Technical Data 1 4 Stand Alone Dryer Washer Dryer Stack inches cm ...

Page 13: ...Technical Data 1 5 Dryer Dryer Stack inches cm ...

Page 14: ... Connections Location Requirements Before installing the dryer be sure the location conforms to local state and national codes In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI Z223 1 LATEST EDITION or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATES...

Page 15: ...ended for ease of installation maintenance and service Flooring should be level and below dryer cabinet for ease of removing panels during maintenance Dryers may be positioned side by side IMPORTANT The Dryer Dryer stacked unit is recommended to be installed by 2 people For stacked washer and dryer unit the washer should be installed in accordance with washer installation manual and tested first M...

Page 16: ...onstricting passageways or where dryers are located at high altitudes or predominantly low pressure areas IMPORTANT Component failure due to dry cleaning solvent fumes will void the warranty Exhaust Requirements Exhaust ductwork should be designed and installed by qualified professional Improperly sized ductwork will create excessive back pressure which results in slow drying increased use of ener...

Page 17: ...tion of a high limit thermostat IMPORTANT When the exhaust ductwork passes through a wall ceiling or roof installation must comply with applicable local and national codes Refer to the National Fuel Gas Code and applicable local codes for ducting requirements Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather a 90 elbow bent downward should be instal...

Page 18: ... ducts from individual dryers may be channeled into a common main duct The individual ducts should enter the bottom or side of the main duct at an angle not more than 45º in the direction of airflow The main duct should be tapered with the diameter increasing before each individual duct is added The multiple dryers must have separate backdraft dampers when connected through a shared venting IMPORT...

Page 19: ...yer must be connected to the electric supply shown on the data label any damage done to dryer components due to improper voltage connections will void the warranty Electrical Service Specifications Gas Heated Models Electric Heated Models All electrically heated dryers must be connected to the electric service shown on the dryer s data label The connecting wires must be properly sized to handle th...

Page 20: ...ductor is prohibited Grounding through the neutral conductor is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes prohibit grounding through the neutral conductors Input connection wiring must be properly sized to carry the dryer s current draw This information is printed on the dryer s data label Electrically heated dryers are n...

Page 21: ...pply piping system during pressure testing Failure to isolate or disconnect the dryer from the gas supply as noted can cause irreparable damage to the gas valve voiding the warranty Undersized gas piping will result in ignition problems slow drying increased use of energy and can create a safety hazard The manufacturer of this appliance does not recommend the use of flexible gas supply line hose I...

Page 22: ...talled in the supply line servicing a bank of dryers For natural gas installation an in line pressure regulator must be installed in the gas supply line if the gas pressure exceeds 10 0 in WC 25 mb pressure A plugged tap accessible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers N G L P G IGNITOR GAS NOZZLE GAS VALVE GAS PIPE GAS SHU...

Page 23: ... Close all shut off valves in the dryer s gas supply line Open the toe panel of the dryer Disconnect ignitor wires from harness and then remove the burner tube Remove the burner orifice from the valve and replace it with the proper orifice Use orifice 44 for NG and orifice 55 for LP Orifice number is stamped on the edge of the hex head of the orifice Securely tighten Put the burner tube on the bur...

Page 24: ... user Gas Pressure Testing For proper operation the gas supply and regulated pressures must be correct Verify correct pressure according to the instructions below This procedure must be carried out by qualified licensed personnel WARNING Turn gas shutoff valve in gas supply line to OFF position Install a pressure tap fitting and attach a manometer Turn gas shutoff valve to ON position Start the dr...

Page 25: ...yer is publicly used It is possible that adjustments have changed in transit or due to marginal location installation conditions Gas Dryers Open all shutoff valves Turn on electric power to the dryer Run the No Heat drying program and check if the drum is rotating properly Run the Low Heat and to check the Ignition Refer to the Operating Instructions for starting your particular model dryer When a...

Page 26: ...wer to the dryer Run the No Heat drying program and check if the drum is rotating properly Check to ensure that electric oven contactor assembly is activating Run the Low Heat and to check the Ignition Refer to the Operating Instructions for starting your particular model dryer ...

Page 27: ... seat 4 Install the coin meter faceplate into the control panel and then assemble the coin meter s into the faceplate 5 Plug the coin meter s into COIN 1 Red and COIN 2 Red harnesses inside the dryer 6 Carefully reattach the coin meter harnesses using the cable ties mounted on the chassis behind the coin meter s Make sure the harnesses do not obstruct coins dropping into the coin vault and that th...

Page 28: ...ent trouble free and most importantly safe operation Daily Clean the lint screen after each load Weekly Clean lint accumulation from lint chamber and temperature sensor area See illustration below Clean the door gasket Use a soft wash cloth and mild detergent to clean door Every Third Month Disconnect Power Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment Va...

Page 29: ...obstructed with lint change to a shorter service interval such as every three months A back draft damper that is sticking partially closed can result in slow drying and the shutdown of heat circuit safety switches or thermostats When cleaning the dryer cabinet avoid using cleaners with harsh abrasives A product intended for appliance cleaning is recommended Every 12 Months A competent professional...

Page 30: ...Sales and Administration 516 371 4400 Spare Parts 516 371 2000 Technical Support 516 371 0700 En Mexico 001 800 010 1010 461 Doughty Blvd Inwood NY 11096 laundrylux com ...