![Wasco WITIO-PCIe192 ULTRA User Manual Download Page 45](http://html1.mh-extra.com/html/wasco/witio-pcie192-ultra/witio-pcie192-ultra_user-manual_3473666045.webp)
45
WITIO-PCIe192
ULTRA
© 2018 by Messcomp Datentechnik GmbH
DV0101
45
WITIO-PCIe192
ULTRA
© 2018 by Messcomp Datentechnik GmbH
EV0103
45
45
wasco
®
wasco
®
Register TIMERCOMPx:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
TIMERCOMPx<31:24>
23:16
R/W
TIMERCOMPx<23:16>
15:8
R/W
TIMERCOMPx<15:8>
7:0
R/W
TIMERCOMPx<7:0>
Bit 31 - 0
TIMERCOMPx<0>
(default = 0)
The value of the register TIMERCOMP determines the interval dura-
tion of the timer.
TIMERCOMP = Interval duration - 1
Register TIMERCOMPx:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
TIMERCOMPx<31:24>
23:16
R/W
TIMERCOMPx<23:16>
15:8
R/W
TIMERCOMPx<15:8>
7:0
R/W
TIMERCOMPx<7:0>
Bit 31 - 0
TIMERCOMPx<0>
(default = 0)
Der Wert des TIMERCOMP-Registers bestimmt die Intervalldauer
des Timers.
TIMERCOMP = Intervalldauer - 1
(x = Timer-Nummer)
(x = Timer number)