24
OPTOIO-PCIe32
ULTRA
© 2019 by Messcomp Datentechnik GmbH
DV02
24
OPTOIO-PCIe32
ULTRA
© 2019 by Messcomp Datentechnik GmbH
EV02
24
24
wasco
®
wasco
®
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R
OPTOIN <31:24>
23:16
R
OPTOIN <23:16>
15:8
R
OPTOIN <15:8>
7:0
R
OPTOIN < 7:0>
Register OPTOIN:
Bit 31 - 0
OPTOIN <31:0>
each bit corresponds to one optocoupler input
(e.g. IN00 = OPTOIN<0>, IN13 = OPTOIN<13>)
If a HIGH is applied to an input, the associated bit is 1, otherwise it
is 0
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
-
23:16
R/W
-
15:8
R/W
OPTOINFILx < 15:8>
7:0
R/W
OPTOINFILx < 7:0>
Register OPTOINFILx:
Bit 31 - 16 reserved (value 0 is written)
Bit 15 - 0
OPTOINFILx <15:0>
(default = 0)
This value determines the filter duration of the filter x in µs
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R
OPTOIN <31:24>
23:16
R
OPTOIN <23:16>
15:8
R
OPTOIN <15:8>
7:0
R
OPTOIN < 7:0>
Register OPTOIN:
Bit 31 - 0
OPTOIN <31:0>
jedes Bit entspricht einem Optokopplereingang
(Z.B. IN00 = OPTOIN<0>, IN13 = OPTOIN<13>)
Liegt an einem Eingang ein HIGH an, so steht in dem dazugehöri-
gen Bit eine 1, ansonsten eine 0
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
-
23:16
R/W
-
15:8
R/W
OPTOINFILx < 15:8>
7:0
R/W
OPTOINFILx < 7:0>
Register OPTOINFILx:
Bit 31 - 16 reserviert ( mit dem Wert 0 beschreiben)
Bit 15 - 0
OPTOINFILx <15:0>
(default = 0)
Der Wert bestimmt die Filterdauer des Filters x in µs