26
WITIO-PCIe192
ULTRA
© 2018 by Messcomp Datentechnik GmbH
DV0101
26
WITIO-PCIe192
ULTRA
© 2018 by Messcomp Datentechnik GmbH
EV0103
26
26
wasco
®
wasco
®
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
DINFILyCNx < 31:24>
23:16
R/W
DINFILyCNx < 23:16>
15:8
R/W
DINFILyCNx < 15:8>
7:0
R/W
DINFILyCNx < 7:0>
Register DINFILyCNx
(1)
:
Bit 31- 0
DINFILyCNx <31:0>
(default = 0)
The value determines the filter duration of the filter y of the connec-
tor x in µs
Offset Address
= 0x640 + DIN Number * 4 (CN1)
= 0x740 + DIN Number * 4 (CN2)
= 0x840 + DIN Number * 4 (CN3)
1
(y = Registernummer, x = Connector-Nummer)
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
DINFILyCNx < 31:24>
23:16
R/W
DINFILyCNx < 23:16>
15:8
R/W
DINFILyCNx < 15:8>
7:0
R/W
DINFILyCNx < 7:0>
Register DINFILyCNx
(1)
:
Bit 31- 0
DINFILyCNx <31:0>
(default = 0)
Der Wert bestimmt die Filterdauer des Filters y des Connectors x
in µs
Offset-Adresse
= 0x640 + DIN-Nummer * 4 (CN1)
= 0x740 + DIN-Nummer * 4 (CN2)
= 0x840 + DIN-Nummer * 4 (CN3)
1
(y = Registernummer, x = Connector-Nummer)
1
(y = Register number, x = Connector number)