Fig 7-6
Example of system oil tank arrangement (DAAE007020e)
Design data:
1.2...1.5 l/kW, see also Technical data
Oil tank volume
75...80% of tank volume
Oil level at service
60% of tank volume
Oil level alarm
7.3.3
New oil tank (2T03)
In engines with wet sump, the lubricating oil may be filled into the engine, using a hose or an
oil can, through the dedicated lubricating oil filling connection (215). Alternatively, trough the
crankcase cover or through the separator pipe. The system should be arranged so that it is
possible to measure the filled oil volume.
7.3.4
Suction strainers (2F01, 2F04, 2F06)
It is recommended to install a suction strainer before each pump to protect the pump from
damage. The suction strainer and the suction pipe must be amply dimensioned to minimize
pressure losses. The suction strainer should always be provided with alarm for high differential
pressure.
7-10
Wärtsilä 20 Product Guide - a13 - 6 September 2016
Wärtsilä 20 Product Guide
7. Lubricating Oil System
Summary of Contents for WARTSILA 20
Page 1: ...W RTSIL 20 PRODUCT GUIDE...
Page 34: ...This page intentionally left blank...
Page 42: ...This page intentionally left blank...
Page 86: ...This page intentionally left blank...
Page 92: ...This page intentionally left blank...
Page 124: ...This page intentionally left blank...
Page 140: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 172: ...This page intentionally left blank...
Page 175: ......
Page 176: ......
Page 177: ......