8.3
External compressed air system
The design of the starting air system is partly determined by classification regulations. Most
classification societies require that the total capacity is divided into two equally sized starting
air receivers and starting air compressors. The requirements concerning multiple engine
installations can be subject to special consideration by the classification society.
The starting air pipes should always be slightly inclined and equipped with manual or automatic
draining at the lowest points.
Instrument air to safety and control devices must be treated in an air dryer.
Fig 8-3
Example of external compressed air system (DAAF432964)
System components
Air dryer unit
3N06
Diesel engine WV46F
01
Compressor (Starting air compressor
unit)
3P01
Diesel engine WV46F
02
Separator (Starting air compressor
unit)
3S01
Flexible pipe connection
3H0X
Starting air vessel
3T01
Air filter (starting air inlet)
3F02
Starting air compressor unit
3N02
Pipe connections
Starting air inlet
301
Control air inlet
302
Driving air to oil mist detector
303
8-6
DAAB605814
Wärtsilä 46F Product Guide
8. Compressed Air System
Summary of Contents for 46F Series
Page 1: ...Wärtsilä 46F PRODUCT GUIDE ...
Page 4: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 18: ...This page intentionally left blank ...
Page 86: ...This page intentionally left blank ...
Page 104: ...This page intentionally left blank ...
Page 154: ...This page intentionally left blank ...
Page 162: ...This page intentionally left blank ...
Page 170: ...This page intentionally left blank ...
Page 176: ...This page intentionally left blank ...
Page 194: ...This page intentionally left blank ...
Page 200: ...This page intentionally left blank ...
Page 202: ...This page intentionally left blank ...
Page 207: ...Fig 21 7 List of symbols DAAF406507 7 DAAB605814 21 5 21 ANNEX Wärtsilä 46F Product Guide ...