background image

(1) CHECK THE ENGINE OIL LEVEL

Notice: Stop the generator in a smooth place, then check the 
generator. Engine oil is a major factor aff ecting engine perfor-
mance and life.

Use the 4-stroke oil, SAE10W-40 is recommended  for general, 
all-temperature use. Other viscosities shown in the chart may be 
used when the average temperature in your area is within the 
indicated range.

1. 

Uncover the oil mouth then clean the engine oil ruler with 
clean cloth. 

2. 

Plug the engine oil ruler into the oil mouth and don’t turn it. If 
the oil level is below the lower limit of the engine oil ruler you 
should add some engine oil.

3. 

Add the engine oil to the upper limit of ruler. 

4. 

Fix the engine oil plug ruler properly.

(2) CHECK THE FUEL LEVEL

Check the fuel gauge, and refi ll the tank if the fuel level is low.   Use the 93# unleaded gasoline or 
higher

1. 

Uncover the fuel tank cap.

2. 

Check the fuel level, if the fuel level is low you should add more.

3. 

Add the fuel to the shoulder part of fuel fi lter.

4. 

Fix the fuel tank cap.

2. CHECKS BEFORE OPERATING

Summary of Contents for WPP-3500CX

Page 1: ...Est St Helens Merseyside WA11 9XQ UK Tel 0044 0 1942 528272 Email sales warriorpowerproducts co uk For any technical or faults please contact warrior direct on the following number or write WPP 3500C...

Page 2: ...7 Do not use in wet condition 8 Keep away from ammable 9 This electrical equipment including lines and plug connections should not be defective 10 When refuelling Stop Engine Do Not Smoke Do Not Spil...

Page 3: ...ngine oil ruler with clean cloth 2 Plug the engine oil ruler into the oil mouth and don t turn it If the oil level is below the lower limit of the engine oil ruler you should add some engine oil 3 Add...

Page 4: ...exposure level can vary from country This information however will enable the user of the machine to make a better evaluation of the hazard and risk MEANING OF CROSSED OUT WHEELED DUSTBIN Do not dispo...

Page 5: ...ep your generator in good condition Please follow the rules 1 Avoid improper operation make sure to make your generator ground connection 2 Electrical equipment motor driven devices will produce lots...

Page 6: ...es All right All right Forbid 3 When you connect more than two loads on the generator please connect from high electric cur rent to low electric current successively When using extension lines or mobi...

Page 7: ...es are closed Storing the engine in this posi tion will help to protect it from internal corrosion 7 TRANSPORTING STORAGE 5 STOPPING THE ENGINE 1 Turn the AC circuit breaker to the OFF position 2 Turn...

Page 8: ...to your local service station for reclamation Do not throw it in the trash or pour it on the ground OIL CAPACITY 0 6L SPARK PLUG SERVICE Recommended spark plug BP6ES SPR6ES NGK F6TC F6RTC LD To ensure...