background image

EC DECLARATION OF CONFORMITY

The Manufacturer of the product covered is:

Winch Solutions Ltd T/A Warrior Generators 
Unit 27 Salisbury Road
Haydock Industrial Estate
St Helens
WA11 9XG - United Kingdom

The manufacturer hereby declares that the machine as detailed in this declaration fulfi ls all the rel-
evant provisions of the Machinery Directive and other appropriate directives as detailed below. The 
manufacture further declares that the machine as detailed in this declaration, where applicable, fulfi ls 
the relevant provisions of the essential health and safety requirements.

Signed: 

   Print: 

Paul 

Bimson

Technical Manager 
Winch Solutions Ltd, 
Unit 27 Salisbury Road, Haydock Ind Est, St Helens, Merseyside, WA11 9XG, UK

Date: 19/12/2014

www.warriorgenerators.co.uk       Tel: +44 (0)1942 528271

Product Details:
Description: Inverter Generator
Model No: DIG1500
Brand Name: Warrior Generator

Name and address of technical documentation holder.
The technical documentation required to demonstrate that the product meets the requirements of
directive has been compiled and is available for inspection by the relevant enforcement authorities.

2006/42/EC The Machinery Directive.
2006/95/EC. Low Voltage Equipment Directive.
2004/108/EC. Electromagnetic Compatibility Directive,
93/68/EC. The CE Marking Directive.
2002/96/EC as amended by 2003/108/ECThe Waste Electrical and Electronic Equipment (WEEE)
Directive.
2002/88/EC. The Emission of Gaseous and Particulate Pollutants from Internal Combustion
Engines to be Installed in Non-Road Mobile Machinery Directive
2000/14/EC, Annex VI, and the Directive 2005/88/EC The Noise Emissions in the Environment
by Equipment for use Outdoors Regulations 2001 (SI 2001/1701 as amended)

EN 12601
EN 55012
EN 61000-6-1
EN ISO 3744

The Directives covered by this Declaration are as detailed below

And is in conformity with the applicable requirements of the following documents

14

Summary of Contents for DIG1500

Page 1: ...Brand Name Warrior Generator Name and address of technical documentation holder The technical documentation required to demonstrate that the product meets the requirements of directive has been compil...

Page 2: ...900W Inverter Generator DIG1500 Always read the instruction manual Retain for future use...

Page 3: ...is adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable...

Page 4: ...or touch with wet hands Check the fuel system periodically for leaks seals and hoses should be checked for signs of deterioration or chafing Check for loose or missing clamps damaged fuel tank or fil...

Page 5: ...match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body...

Page 6: ...sures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to ope...

Page 7: ...NK VENT TAP 3PARK PLUG MAINTENANCE COVER XHAUST CHARGING LEADS 3CREWDRIVER 3PARK PLUG SPANNER 4ECHNICAL SPECIFICATION OUTPUT 6 Z 2ATED POWER K6 0EAK POWER K6 0 2ATED CURRENT HASE 3INGLE 0OWER FACTOR C...

Page 8: ...NG A WIRE AND A SMALL EARTH STAKE OTE 4HE WIRE AND EARTH STAKE ARE NOT SUPPLIED WITH THE UNIT ARTH SPIKE AND CABLE CAN BE PURCHASED AT YOUR LOCAL CAMPING SUPPLIES OR ALTERNATIVELY AN EARTH SPIKE CAN B...

Page 9: ...s engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life Warning Never use stale or contaminated gasoline o...

Page 10: ...NG PLATE NSURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER AND THAT THE MAINS SUPPLY LEAD IS LONG ENOUGH TO REACH THE GENERATOR WITHOUT ANY STRAIN 7HEN THE GENERATOR ENGINE HAS BEEN SU...

Page 11: ...ELPS IN FUEL ECONOMY AND REDUCED NOISE LEVELS WHEN UNDER NO LOAD CONDITIONS 7HEN A LOAD IS CONNECTED TO THE GENERATOR THE GENERATOR SPEED WILL AUTOMATICALLY ADJUST IN ORDER TO SUPPLY ENOUGH POWER PPLI...

Page 12: ...SIMULTANEOUSLY 4HIS IS NORMAL THE 2ED OVER LOAD INDICATOR EXTINGUISHES AFTER ABOUT FOUR SECONDS F THE 2ED OVERLOAD INDICATOR REMAINS ILLUMINATED CONSULT YOUR GENERATOR DEALER AUTION 3UBSTANTIAL OVERLO...

Page 13: ...er the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a...

Page 14: ...lter thoroughly using an environmentally friendly water based degreasing agent and re fit Air Filter A dirty air cleaner will restrict air flow to the carburettor To prevent carburettor malfunction se...

Page 15: ...rom the fuel tank and the carburettor ensure that all the fuel has been removed Remove the spark plug and pour approximately one tablespoon full of clean engine oil into the spark plug hole With the i...

Page 16: ...15 TROUBLESHOOTING...

Page 17: ...TROUBLESHOOTING 16...

Page 18: ...ling Check fan damage system Starting Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required Th...

Page 19: ...sposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropriate wast...

Page 20: ...ECYCLE WHERE FACILITIES EXIST HECK WITH YOUR OCAL UTHORITY OR RETAILER FOR RECYCLING ADVICE ENERAL WARNING 7EAR HEARING PROTECTION 7EAR EYE PROTECTION 7EAR RESPIRATORY PROTECTION 54 4HIS IS A STROKE E...

Page 21: ...x mm 47 41 5 Displacement 72cc Max Output 2 1KW 5500rpm Fuel Regular Automobile Gasoline Fuel tank Capacity 3 6 litres Rated Continuous Operation 4 3hr 4 3hr 4 0hr Lubricating oil SAE 10W30 Lubricati...

Page 22: ...5cc Max Output 3 5KW 5500rpm 3 5KW 5500rpm 4 0KW 5500rpm Fuel Regular Automobile Gasoline Fuel tank Capacity 5 7 litres Rated Continuous Operation 4h30min 100 Load 5h50min 50 Load 4h10min 100 Load 5h...

Page 23: ...Stepping motor BL BL Main BL BL BL R BL BL R R BL AC SOCKET R DC SOCKET Y G Winding Control winding R R BL BL W BL W BL Oil sensor Invert cell BL O BL BL R BL BR GR BU Y G O W BU P Economic switch PI...

Page 24: ...ng Control winding R R O O BL W PI BL BU BU BL BL BL BL R R BL BL W BL W BL Oil sensor BL R BL BL R Invert cell BL O BL BL R R BL BR GR BU Y G O W BU P R BL Economic switch PILOT OVERLOAD LOW OIL Engi...