The floor which the stove is to be located on must have an adequate load-bearing capacity. If 
the floor does not meet this requirement then suitable measures in accordance with building 
control regulations need to be taken. 
 
This stove has passed the requirements of building regulations so that it only requires a 12mm  
Thickness hearth. 
 
The stove must be located on a solid non combustible hearth/surface with the minimum  
dimensions extending from the perimeter of the stove as shown below: 
 
 
 
 
 
 
 
 
 
 
 
 
 
The stove surfaces must have a minimum distance away from any combustible materials as 
listed in the technical data section of this manual.   
Single wall fluepipes must be more than three times the diameter of the fluepipe away from 
combustible materials i.e. 125mm (5”) Fluepipe should be a minimum of 375mm (15”) away.   
For further assistance regarding flue pipe & liners please contact your stove dealer, approved 
installer, building control officer or Midtherm Flue Systems Ltd. (Details listed at rear of this 
manual).  The complete range of Midtherm flues and ancillary components are available from 
your stove retailer.   
Further advice regarding chimney and flues for this stove is detailed in the Installation  
section of this manual. 
 
This stove must have its own dedicated chimney or flueway.  It is not suitable for installing 
into a shared flueway.  The stove must always have a permanent free air supply into the room it 
is being installed into.  For Stoves rated above 5KW a permanent unobstructed air vent is  
required.  This vent should be in the same or adjoining room as the stove and must be  
connected directly to the outside air, where possible locate the vent close to the stove to  
confine draughts.  The vent size should be a minimum of 550mm

per KW over 5 KW, i.e.    

A stove rated at 11kw would need a minimum vent size of 3,300mm

for modern properties 

(Generally only since 2008) with Design Air Permeability greater than or equal to 5.0Mtr

3

/

(h.m

2

) then 550mm

2

 is required per kW output.  It is always advisable to install a vent if there 

is not one present for a stove rated under 5Kw and like wise it is better to install a vent larger 
than the minimum recommended size.  This is to account for the possibility of operating the 
stove at more than its rated output.     
Extractor fans operating in the same room or air space as the stove may cause problems with 
the air supply to the stove which in turn may cause problems with chimney draw. 
 
Your approved installer or building control officer should be familiar with all these aspects of 
where the stove may be installed. 

STOVE LOCATION 

A=150mm 
B=225mm 
C=150mm 
D=150mm 

Front of stove 

These distances may be  
reduced if the Hearth 
adjoins a non  
combustible wall. 

Summary of Contents for WSDAID

Page 1: ...lly and thoroughly read this manual prior to any installation or lighting of your new stove If you have any questions regarding this stove which are not mentioned in this manual then please contact th...

Page 2: ...ALLATION Including Chimney Guidance 5 12 STOVE OPERATION 13 16 STOVE AND CHIMNEY MAINTENANCE 17 18 TROUBLESHOOTING 19 PARTS DIAGRAM 20 LIST OF USEFULADDRESS S 21 INSTALLATION RECORD 22 MAINTENANCE REC...

Page 3: ...entre of flue mm 130 Flue Diameter Req mm 150 Net weight Kg 210 Gross weight Kg Packed 220 Minimum distance to Combustible surfaces Top 800mm Side 450mm Rear 1200mm Type of boiler and method of constr...

Page 4: ...this manual for further reference Most stove retailers will be able to assist in advising a competent person for installation WARRIOR Stoves installation instructions cannot be taken as conforming to...

Page 5: ...ed chimney or flueway It is not suitable for installing into a shared flueway The stove must always have a permanent free air supply into the room it is being installed into For Stoves rated above 5KW...

Page 6: ...ve which require fixing these parts should be The Legs the Stove Outlet and the Stove Outlet Blanking Plate and the Handles These parts should be easily identifiable from the exploded parts diagram li...

Page 7: ...d into an existing chimney ensure that protective eye ware is worn during inspection and whilst attending to any remedial work that may be required In the case of installing into old Chimneys particul...

Page 8: ...ear of the stove the maximum horizontal run should not exceed 150mm Provision must be made for cleaning the entire length of the chimney flue other than through the stove The Flue way must be kept war...

Page 9: ...lems with the chimney draw The connecting flue pipe must be sealed to the chimney with fire cement and high temperature resistant rope as required This is usually done into a register Blanking plate w...

Page 10: ...tant board The Flue Pipe must be 3 times it s diameter away from combustible materials For example 150mm Flue Pipe must be 450mm away from combustible materials FLUE Sealed door to access chimney for...

Page 11: ...here this flue pipes passes through a combustible floor a ventilated fire stop kit must be used Some typical installations are shown as following Rain cap Cowl 600mm minimum One load bearing support e...

Page 12: ...ast 1000mm above the highest point of intersection of the chimney and the weather surface or B at least as high as the ridge C Below on a pitched roof or within 2300mm hori zontally to an open able ro...

Page 13: ...solid fuel appliance or open fire appliance fitted at the base or the bottom of the chimney heat the inside of the Appliance Fireplace chamber with a blow Lamp gas stove or similar device for approx...

Page 14: ...hat cannot be harmed by heat in the opening at the base of the flue or in the appliance if it is fitted Always follow the pellet manufacturer s safety instructions Ignite pellet and open all vents to...

Page 15: ...ost important It should be readily identified by the parts diagram and is located on the lower section of the stove Air enters the stove by this control and it is the amount of air allowed to enter th...

Page 16: ...ron and should be seasoned Seasoning is the process of gradually warming through the castings of the stove to allow all components to heat up and cool down together without causing any damage to the s...

Page 17: ...st NOT be used in your stove the use of such fuel will invalidate your guarantee as will the use of smaller sized fuels that can clog the grate Fuels which have a maximum dimension of less than 35mm a...

Page 18: ...should be regulated similarly to the air inlet controls the further closed then the slower the fire burn rate will be Observe the note in the Air control section regarding use of damper whilst the sto...

Page 19: ...dependant upon usage and fuel type The inside of the stove should be cleaned at least Monthly during peak usage to remove any build up of deposits from the products of combustion experience will advis...

Page 20: ...and any fragments Penetrating oil may assist in removing the machine screws if they are proving difficult to undo If the rope seal that the glass rests on is undamaged then the glass can be placed on...

Page 21: ...that require attention Ensure the procedures in the Stove and Chimney Maintenance section are adhered to During operation nominal fume and smoke emission may occur when refuelling or emptying the ash...

Page 22: ...Top Outlet Connecting Plate 15 Tertiary Air burn Plate 16 Back Boiler 17 Flue Blanking Plate Rear 18 Refractory Fire Brick 19 Left Plate 20 Baffle Plate Lower Section 31 Door Handle Catch 32 Door Han...

Page 23: ...of Master Sweeps The Bungalow London Road Attleborough Norfolk NR17 2DE T 01953 451322 W www guild of master sweeps co uk E contactus guild of master sweeps co uk Solid Fuel Association 7 Swanwick Cou...

Page 24: ...imney Sweeps Ltd APIC Bryallen Hengar Road St Tudy Bodmin Cornwall PL30 3PL T 0845 604 4327 Water Regulations Advisory Scheme Fern Close Pen Y Fan Industrial Estate Oakdale Gwent NP11 3EH T 01495 2484...

Page 25: ...spection and testing after completion Tests carried out by Tests Appx E in AD J 2002 ed and results Flue visual Inspection sweeping coring ball smoke Appliance where included spillage 1 Building addre...

Page 26: ...me Address Registered Member of Work Conducted Installation Chimney Safe Y N Sign Name Print Please kindly ensure this Maintenance Record is completed by the engineer every time work is completed on e...

Page 27: ...ARRIOR Stoves Ltd The stove dealer will require the model receipt invoice the installation and service records your full contact details description of the fault and the fuel type brand used where app...

Page 28: ...nge of products please visit our website at WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK WWW WARRIORSTOVES CO UK OR E mail us to find your nearest stockist at info warriorst...

Reviews: