background image

sandpiperpump

.

com

Model SH2-M • 

9

sh2mdl7sm-rev1218

Principle of Pump Operation

Troubleshooting Guide

TROUBLE SHOOTING

1. 

Pump will not cycle

A. 

Check to make sure the unit has enough pressure to operate and that the air inlet valve is open.

B. 

Check the discharge line to insure that the discharge line is neither closed nor blocked.

C. 

If the spool in the air distribution valve is not shifting check the main spool. It must slide freely.

D.  Excessive air leakage in the pump can prevent cycling. Air leakage from the exhaust port indicates leakage in the air distribution 

valve. See further service instructions.

E. 

Blockage in the liquid chamber can impede movement of diaphragm.

2. 

Pump cycles but will not pump

A. 

Suction side of pump pulling in air. Check the suction line for air leaks and be sure that the end of the suction line is submerged. 

Check flange bolting. Check valve flanges and manifolds to chamber flange joints.

B. 

Make certain the suction line or strainer is not plugged. Restriction at the suction is indicated by a high vacuum reading when a 

vacuum gauge is installed in the suction line.

C. 

Check valves may not be seating properly. To check, remove the suction line and cover the suction port with your hand. If the 

unit does not pull a good suction (vacuum), the check valves should be inspected for proper seating.

D.  Static suction life may be too high. Priming can be improved by elevating the suction and discharge lines higher than the check 

valves and pouring liquid into the unit through the suction inlet. When priming at high suction lifts or with long suction lines oper-

ate the pump at maximum cycle rate.

3. 

Low performance

A. 

Capacity is reduced as the discharge pressure increases. Performance capability varies with available inlet supply. Check air 

pressure at the pump inlet when the pump is operating to make certain that adequate air supply is maintained.

B. 

Check vacuum at the pump suction. Capacity is reduced as vacuum increases. Reduced flow rate due to starved suction will be 

evident when cycle rate can be varied without change in capacity. This condition will be more prevalent when pumping viscous 

liquids. When pumping thick, heavy material the suction line must be kept as large in diameter and as short as possible, to keep 

suction loss minimal.

C. 

Low flow rate and slow cycling rate indicate restricted flow through the discharge line. Low flow rate and fast cycling rate indicate 

restriction in the suction line or air leakage into suction. For more information, refer to the Warren Rupp Troubleshooting Guide.

WARRANTY: 

This unit is guaranteed for a period of five years against defective material and workmanship.

For high pressure pumps used in conjunction with another diaphragm pump in “skid mount” system: The EH2-M will not prime against the 

head created by the fill pump. Run both simultaneously at start-up.

RECOMMENDED WARREN RUPP

® 

ACCESSORIES

TO MAXIMIZE PUMP PERFORMANCE:

• Tranquilizer

® 

Surge Suppressor. For nearly pulse-free flow.

• Warren Rupp Air Dryer. For clean, dry compressed air.

• Warren Rupp Filter/Regulator. For modular installation and service convenience.

• Warren Rupp Speed Control. For manual or programmable process control. Manual adjustment or 

4-20mA reception.

For more detailed information on these accessories, contact your local

Warren Rupp Factory-Authorized Distributor, or Warren Rupp corporate headquarters.

UNIVERSAL ALL SANDPIPER, EXCEPT FLAP

2: INST

AL

 & OP

Summary of Contents for SANDPIPER SH2-M

Page 1: ...ion 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM 2017 Warren Rupp Inc Certified Quality ISO 9001 Certified ISO 14001 Certified SERVICE OPERATING MAN...

Page 2: ...d fluids are thoroughly flushed WARNING The use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp...

Page 3: ...to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natural...

Page 4: ...uide Troubleshooting Guide SECTION 3 EXPLODED VIEW 8 Composite Repair Parts Drawing Composite Repair Parts List Down Ported Option Drawing Material Codes SECTION 4 AIR END 12 Air Distribution Valve As...

Page 5: ...agm Check Valve Materials B Nitrile I EPDM N Neoprene V FKM Your Serial fill in from pump nameplate ______________________________________ __ _____ __ ___ __ __ Pump Pump Size Discharge Diaphragm Desi...

Page 6: ...PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Santoprene Inject...

Page 7: ...5 36 136 11 47 291 5 33 135 15 07 383 16 51 419 2 09 53 2 00 51 26 79 681 19 5 19 5 EXHAUST PORT 1 NPT AIR INLET 1 2 NPT DISCHARGE PORT 2 NPT FEMALE SUCTION PORT 2 NPT FEMALE 19 03 483 11 37 289 12 19...

Page 8: ...ally shortened pump life The hose assemblies deliver air to the non wetted portions of the pump and care should be taken that they are neither crimped nor cut INSTALLATION PROCEDURES Position the pump...

Page 9: ...mp at maximum cycle rate 3 Low performance A Capacity is reduced as the discharge pressure increases Performance capability varies with available inlet supply Check air pressure at the pump inlet when...

Page 10: ...8 9 20 62 41 10 11 12 13 52 14 15 40 48 37 65 16 17 18 30 21 22 24 25 25 23 57 26 46 19 60 27 28 64 36 64 36 29 56 55 38 49 44 55 29 44 49 38 46 65 37 58 42 42 45 39 42 47 50 54 50 61 60 50 53 50 34 6...

Page 11: ...ed with item 2 1 10 115 062 080 Bracket Mounting Left Hand 1 11 115 063 080 Bracket Mounting Right Hand 1 12 115 075 080 Bracket Mounting 1 13 132 002 360 Bumper Diaphragm 2 14 132 014 358 Bumper Air...

Page 12: ...pylene 379 Conductive Nitrile 408 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 15...

Page 13: ...7 C 7 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 7 F Step 2 Remove sleeve 7 B inspect O Rings 7 C replace if required Step 3 Remove spool 7 D from sleeve 7 B i...

Page 14: ...ration Consult the pump s published performance curve to determine this It is important to remember to inspect the sleeve and spool set routinely It should move back and forth freely This is most impo...

Page 15: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 16: ...Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma...

Reviews: