background image

s30mdl1sm-rev1218

sandpiperpump

.

com

Model S30 Metallic • 

9

Air-Operated Double Diaphragm (AODD) pumps are powered 

by compressed air or nitrogen.

The main directional (air) control valve 

 distributes 

compressed air to an air chamber, exerting uniform pressure 

over the inner surface of the diaphragm  

. At the same time, 

the exhausting air 

 

from behind the opposite diaphragm  

is directed through the air valve assembly(s) to an exhaust  

port 

.

As inner chamber pressure 

(P1)

 exceeds liquid chamber 

pressure 

(P2)

, the rod 

 connected diaphragms shift 

together creating discharge on one side and suction on the 

opposite side. The discharged and primed liquid’s directions 

are controlled by the check valves (ball or flap)

 orientation. 

The pump primes as a result of the suction stroke. The 

suction stroke lowers the chamber pressure 

(P3)

 increasing 

the chamber volume. This results in a pressure differential 

necessary for atmospheric pressure 

(P4)

 to push the fluid 

through the suction piping and across the suction side check 

valve and into the outer fluid chamber 

.

Suction (side) stroking also initiates the reciprocating 

(shifting, stroking or cycling) action of the pump. The suction 

diaphragm’s movement is mechanically pulled through its 

stroke. The diaphragm’s inner plate makes contact with an 

actuator plunger aligned to shift the pilot signaling valve. 

Once actuated, the pilot valve sends a pressure signal to the 

opposite end of the main directional air valve, redirecting the 

compressed air to the opposite inner chamber.

Principle of Pump Operation

Air Line

Discharged 

Fluid

Discharge

Stroke

Suction

Stroke

Primed

Fluid

SAFE AIR

EXHAUST

DISPOSAL

AREA

PUMP INSTALLATION AREA

1"  DIAMETER AIR

EXHAUST PIPING

1"  DIAMETER AIR

EXHAUST PIPING

1"  DIAMETER AIR

EXHAUST PIPING

MUFFLER

LIQUID

LEVEL

SUCTION

LINE

LIQUID

LEVEL

SUCTION

LINE

MUFFLER

MUFFLER

SUBMERGED ILLUSTRATION

Pump can be submerged if the pump materials of construction 

are compatible with the liquid being pumped. The air exhaust 

must be piped above the liquid level. When the pumped product 

source is at a higher level than the pump (flooded suction 

condition), pipe the exhaust higher than the product source to 

prevent siphoning spills.

UNIVERSAL ALL AODD

2: INST

AL

 & OP

Summary of Contents for SANDPIPER S30

Page 1: ...ield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved OPTIMIZED PERFORMANCE Certified Quality ISO 9001 Certified ISO 14001 Ce...

Page 2: ...use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant non OEM parts...

Page 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Page 4: ...posite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate A...

Page 5: ...Gb II 2 D Ex h mb tb IIIC T100 C Db A H S A C Y 0 6 A1 A2 A3 A4 S05 M ATEX Details Wetted Material Options Non Wetted Material Options Pump Options Kit Options II 1 G Ex h IIC T5 225 C T2 Ga II 1D Ex...

Page 6: ...82 C 32 F 0 C PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Sa...

Page 7: ...761 3 74 95 11 76 299 3 74 95 8 84 225 15 75 400 16 72 425 DISCHARGE PORT 3 NPT 3 BSPT SUCTION PORT 3 NPT 3 BSPT METALLIC MUFFLER DIMENSION 12 00 305 6 00 152 4 91 125 10 13 257 6 84 AIR INLET 3 4 NP...

Page 8: ...E PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE METALLIC MUFFLER DIMENSION SUCTION PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE 4 91 125 6 84 10 13 257 12...

Page 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Page 10: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Page 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Page 12: ...059 XXX CA 14 196 164 XXX 15 196 165 XXX 16 286 098 XXX 17 286 098 604 18 360 093 360 19 360 114 360 20 360 104 379 21 360 105 360 22 518 143 XXX 23 518 144 XXX 24 545 007 XXX 25 545 008 XXX 26 560 00...

Page 13: ...er 1 031 147 000 Air Valve Assembly stroke Indicator w no muffler 1 2 050 014 354 Ball Check Santoprene 4 050 014 351 Ball Check Food Grade Santoprene 4 050 014 360 Ball Check Buna 4 050 014 360W Ball...

Page 14: ...GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425...

Page 15: ...115 Hex Head Capscrew 1 4 20 x 75 8 1 J 706 026 115 Machine Screw 4 IMPORTANT Read these instructions completely before installation and start up It is the responsibility of the purchaser to retain t...

Page 16: ...C 132 029 357 Bumper 2 1 D 560 020 360 O Ring 10 1 E 165 127 110 Cap End 2 1 F 170 032 115 Hex Head Capscrew 1 4 20 x 75 8 1 A Note Cannot be used with Integral Muffler option 0 IMPORTANT Read these i...

Page 17: ...9 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1...

Page 18: ...mber Description Qty 4 095 110 558 Pilot Valve Assembly 1 4 A 095 095 558 Valve Body 1 includes all other items used on 095 110 000 For Pumps with Stainless Steel Center Section Item Part Number Descr...

Page 19: ...9 from center of intermediate pilot valve cavity Step 2 Remove Ring Retaining 30 discard Step 3 Remove bushing plunger 7 inspect for wear and replace if necessary with genuine parts Step 4 Remove O Ri...

Page 20: ...ump com 20 Model S30 Metallic Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay 16 17 28 9 14 24 24 31 25 15 13 6 27 16 28 9 14 24 24 31 25 15 13 6 27 16 17 28 9 14 24 24 31...

Page 21: ...thoverlays nolubricationisrequired Step 4 Push the threaded outer diaphragm plate through the center hole of the diaphragm Note Most diaphragms are installed with the natural bulge out towards the flu...

Page 22: ...Solenoid Coil 120VAC 60 Hz 1 219 009 002 Solenoid Coil 240VAC 60 Hz 1 219 009 003 Solenoid Coil 12VDC 1 219 009 004 Solenoid Coil 24VDC 1 219 009 005 Solenoid Coil 110VAC 50 Hz 1 219 009 006 Solenoid...

Page 23: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 24: ...es MSA Series U Series F Series T Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex h II...

Reviews: