background image

s30mdl1sm-rev1218

sandpiperpump

.

com

22

 • Model S30 Metallic 

Solenoid Shifted Air Valve Parts List

(Includes all items used on Composite Repair Parts List 

 

except as shown)

Item 

Part Number 

Description 

Qty

893-097-000 

Solenoid Valve, NEMA4 1 

219-001-000 

Solenoid Coil, 24VDC 

1

 

219-004-000 

Solenoid Coil, 24VAC/12VDC 

1

 

219-002-000 

Solenoid Coil, 120VAC 

1

 

219-003-000 

Solenoid Coil, 240VAC 

1

241-001-000 

Connector, conduit 

1

 

241-003-000 

Conduit Connector with 

1

 

 

Suppression Diode (DC Only)

170-029-330 

Capscrew, Hex HD 5/16-18 x 1.25        4

618-051-150 

Plug  

2

171-053-330 

Capscrew, Socket Head                        4

*Special Conditions For Safe Use

A fuse corresponding to its rated current (max. 3*I

rat

 according IEC 60127-2-1) or a  

motor protecting switch with short-circuit and thermal instantaneous tripping (set to rated 

current) shall be connected in series to each solenoid as short circuit protection. For 

very low rated currents of the solenoid the fuse of lowest current value according to 

the indicated IEC standard will be sufficient. The fuse may be accommodated in the 

 

associated supply unit or shall be separately arranged. The rated voltage to the fuse 

shall be equal to or greater than the stated rated voltage of the magnet coil. The  

breakage capacity of the fuse-link shall be as high as or higher than the maximum 

expected short circuit current at the location of the installation (usually 1500 A). A  

maximum permissible ripple of 20% is valid for all magnets of direct-current design. 

IEC EEX m T4

         For Explosion Proof Solenoid Coils used in North America and    

 

outside the European Union.

 

219-009-001 

Solenoid Coil, 120VAC 60 Hz

                1

 

219-009-002 

Solenoid Coil, 240VAC 60 Hz

                1 

 

 

219-009-003 

Solenoid Coil, 12VDC                            1

 

219-009-004 

Solenoid Coil, 24VDC                            1

 

 

219-009-005 

Solenoid Coil, 110VAC 50 Hz                1

 

 

219-009-006 

Solenoid Coil, 230VAC 50 Hz                1

 

Note: Item 43 (Conduit Connector) is not required

II 2G EEx m c T5
II 2D c IP65 T100°C

         For ATEX Compliant Solenoid Coils used in the European Union 

 

219-011-001      Solenoid Coil, Single mounting 

 

 

 

12 VDC, 3.3W / 267mA 

1

 

219-011-002      Solenoid Coil, Single mounting 

 

 

 

24 VDC, 3.3W / 136mA 

1

 

219-011-003      Solenoid Coil, Single mounting 

 

 

 

110/120 VAC, 3.4W / 29mA 

1

 

219-011-004      Solenoid Coil, Single mounting 

 

 

 

220/240 VAC, 3.4W / 15mA 

1

 

Note: Item 35 (Conduit Connector) is not required

*

II 2G EEx 

m

 c II T5

II 2D c IP65 T100°C

Compressed Air  Temperature  Range:

  Maximum Ambient 

Temperature to plus 50°C

Solenoid Shifted Air Valve

3

2

4

5

1

6

#2 Terminal 

Neutral 

(Negative)

#1 Terminal 

Power 

(Positive)

3rd Terminal 

for ground

Wiring 

Diagram

Solenoid Shifted Operation

The Solenoid Shifted SANDPIPER has a solenoid operated, air distribution 

valve in place of the standard SANDPIPER’s pilot operated, air distribution 

valve. Where a pilot valve is normally utilized to cycle the pump’s air distribution 

valve, an electric solenoid is utilized. As the solenoid is powered, one of the 

pump’s air chambers is pressurized while the other chamber is exhausted. When 

electric power is turned off, the solenoid shifts and the pressurized chamber 

is exhausted while the other chamber is pressurized. By alternately applying 

and removing power to the solenoid, the pump cycles much like a standard 

SANDPIPER pump, with one exception. This option provides a way to precisely 

control and monitor pump speed.

Before Installation

Before wiring the solenoid, make certain it is compatible with your system 

voltage.

2

2

MODEL SPECIFIC

6: OPTIONAL

Summary of Contents for SANDPIPER S30

Page 1: ...ield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved OPTIMIZED PERFORMANCE Certified Quality ISO 9001 Certified ISO 14001 Ce...

Page 2: ...use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warrant non OEM parts...

Page 3: ...0 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Natur...

Page 4: ...posite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate A...

Page 5: ...Gb II 2 D Ex h mb tb IIIC T100 C Db A H S A C Y 0 6 A1 A2 A3 A4 S05 M ATEX Details Wetted Material Options Non Wetted Material Options Pump Options Kit Options II 1 G Ex h IIC T5 225 C T2 Ga II 1D Ex...

Page 6: ...82 C 32 F 0 C PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F 121 C 0 F 18 C Sa...

Page 7: ...761 3 74 95 11 76 299 3 74 95 8 84 225 15 75 400 16 72 425 DISCHARGE PORT 3 NPT 3 BSPT SUCTION PORT 3 NPT 3 BSPT METALLIC MUFFLER DIMENSION 12 00 305 6 00 152 4 91 125 10 13 257 6 84 AIR INLET 3 4 NP...

Page 8: ...E PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE METALLIC MUFFLER DIMENSION SUCTION PORT 3 RAISED FACE ANSI STYLE 150 LB FLANGE OR 80 DIN 10 BAR FLANGE 4 91 125 6 84 10 13 257 12...

Page 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Page 10: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Page 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Page 12: ...059 XXX CA 14 196 164 XXX 15 196 165 XXX 16 286 098 XXX 17 286 098 604 18 360 093 360 19 360 114 360 20 360 104 379 21 360 105 360 22 518 143 XXX 23 518 144 XXX 24 545 007 XXX 25 545 008 XXX 26 560 00...

Page 13: ...er 1 031 147 000 Air Valve Assembly stroke Indicator w no muffler 1 2 050 014 354 Ball Check Santoprene 4 050 014 351 Ball Check Food Grade Santoprene 4 050 014 360 Ball Check Buna 4 050 014 360W Ball...

Page 14: ...GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 425...

Page 15: ...115 Hex Head Capscrew 1 4 20 x 75 8 1 J 706 026 115 Machine Screw 4 IMPORTANT Read these instructions completely before installation and start up It is the responsibility of the purchaser to retain t...

Page 16: ...C 132 029 357 Bumper 2 1 D 560 020 360 O Ring 10 1 E 165 127 110 Cap End 2 1 F 170 032 115 Hex Head Capscrew 1 4 20 x 75 8 1 A Note Cannot be used with Integral Muffler option 0 IMPORTANT Read these i...

Page 17: ...9 360 O Ring 2 For Pumps with PTFE Coated Hardware 1 031 146 002 Air Valve Assembly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1...

Page 18: ...mber Description Qty 4 095 110 558 Pilot Valve Assembly 1 4 A 095 095 558 Valve Body 1 includes all other items used on 095 110 000 For Pumps with Stainless Steel Center Section Item Part Number Descr...

Page 19: ...9 from center of intermediate pilot valve cavity Step 2 Remove Ring Retaining 30 discard Step 3 Remove bushing plunger 7 inspect for wear and replace if necessary with genuine parts Step 4 Remove O Ri...

Page 20: ...ump com 20 Model S30 Metallic Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay 16 17 28 9 14 24 24 31 25 15 13 6 27 16 28 9 14 24 24 31 25 15 13 6 27 16 17 28 9 14 24 24 31...

Page 21: ...thoverlays nolubricationisrequired Step 4 Push the threaded outer diaphragm plate through the center hole of the diaphragm Note Most diaphragms are installed with the natural bulge out towards the flu...

Page 22: ...Solenoid Coil 120VAC 60 Hz 1 219 009 002 Solenoid Coil 240VAC 60 Hz 1 219 009 003 Solenoid Coil 12VDC 1 219 009 004 Solenoid Coil 24VDC 1 219 009 005 Solenoid Coil 110VAC 50 Hz 1 219 009 006 Solenoid...

Page 23: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 24: ...es MSA Series U Series F Series T Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex h II...

Reviews: